/* xsns_69_opentherm.ino - OpenTherm protocol support for Tasmota Copyright (C) 2020 Yuriy Sannikov This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version. This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details. You should have received a copy of the GNU General Public License along with this program. If not, see . */ #ifdef USE_OPENTHERM #define XSNS_69 69 #include // Hot water and boiler parameter ranges #define OT_HOT_WATER_MIN 23 #define OT_HOT_WATER_MAX 55 #define OT_BOILER_MIN 40 #define OT_BOILER_MAX 85 #define OT_HOT_WATER_DEFAULT 36; #define OT_BOILER_DEFAULT 85; // Seconds before OT will make an attempt to connect to the boiler after connection error #define SNS_OT_DISCONNECT_COOLDOWN_SECONDS 10 // Count of the OpenThermSettingsFlags #define OT_FLAGS_COUNT 6 enum OpenThermSettingsFlags { // If set, central heating on/off state follows diagnostic indication bit(6), however // EnableCentralHeating flag has a priority over it EnableCentralHeatingOnDiagnostics = 0x01, // If set, DHW is on after restart. EnableHotWater = 0x02, // If set, keep CH always on after restart. If off, follows the EnableCentralHeatingOnDiagnostics rule EnableCentralHeating = 0x04, EnableCooling = 0x08, EnableTemperatureCompensation = 0x10, EnableCentralHeating2 = 0x20, }; enum OpenThermConnectionStatus { OTC_NONE, // OT not initialized OTC_DISCONNECTED, // OT communication timed out OTC_CONNECTING, // Connecting after start or from DISCONNECTED state OTC_HANDSHAKE, // Wait for the handshake response OTC_READY, // Last Known Good response state is SUCCESS and no requests are in flight OTC_INFLIGHT // Request sent, waiting from the response }; OpenThermConnectionStatus sns_ot_connection_status = OpenThermConnectionStatus::OTC_NONE; uint8_t sns_ot_disconnect_cooldown = 0; OpenTherm *sns_ot_master = NULL; // Has valid values if connection status is READY or INFLIGHT typedef struct OT_BOILER_STATUS_T { // Boiler fault code uint8_t m_fault_code; // Boiler OEM fault code uint8_t m_oem_fault_code; // Boilder OEM Diagnostics code uint16_t m_oem_diag_code; // OpenTherm ID(3) response. uint8_t m_slave_flags; // OpenTherm ID(1) codes. Should be used to display state unsigned long m_slave_raw_status; // Desired boiler states bool m_enableCentralHeating; bool m_enableHotWater; bool m_enableCooling; bool m_enableOutsideTemperatureCompensation; bool m_enableCentralHeating2; // Some boilers has an input for the heat request. When short, heat is requested // OT ID(0) bit 6 may indicate state of the Heat Request input // By enabling this bit we will set m_enableCentralHeating to true when OT ID(0) bit 6 is set. // This enables to use external mechanical thermostat to enable heating. // Some of the use cases might be setting an emergency temperature to prevent freezing // in case of the software thermostat failure. bool m_useDiagnosticIndicationAsHeatRequest; // Hot Water temperature float m_hotWaterSetpoint_read; // Flame Modulation float m_flame_modulation_read; // Boiler Temperature float m_boiler_temperature_read; // Boiler desired values float m_boilerSetpoint; float m_hotWaterSetpoint; } OT_BOILER_STATUS; OT_BOILER_STATUS sns_ot_boiler_status; const char *sns_opentherm_connection_stat_to_str(int status) { switch (status) { case OpenThermConnectionStatus::OTC_NONE: return "NONE"; case OpenThermConnectionStatus::OTC_DISCONNECTED: return "FAULT"; case OpenThermConnectionStatus::OTC_CONNECTING: return "CONNECTING"; case OpenThermConnectionStatus::OTC_HANDSHAKE: return "HANDSHAKE"; case OpenThermConnectionStatus::OTC_READY: return "READY"; case OpenThermConnectionStatus::OTC_INFLIGHT: return "BUSY"; default: return "UNKNOWN"; } } void sns_opentherm_init_boiler_status() { memset(&sns_ot_boiler_status, 0, sizeof(OT_BOILER_STATUS)); // Settings sns_ot_boiler_status.m_useDiagnosticIndicationAsHeatRequest = Settings.ot_flags & (uint8_t)OpenThermSettingsFlags::EnableCentralHeatingOnDiagnostics; sns_ot_boiler_status.m_enableHotWater = Settings.ot_flags & (uint8_t)OpenThermSettingsFlags::EnableHotWater; sns_ot_boiler_status.m_enableCentralHeating = Settings.ot_flags & (uint8_t)OpenThermSettingsFlags::EnableCentralHeating; sns_ot_boiler_status.m_enableCooling = Settings.ot_flags & (uint8_t)OpenThermSettingsFlags::EnableCooling; sns_ot_boiler_status.m_enableOutsideTemperatureCompensation = Settings.ot_flags & (uint8_t)OpenThermSettingsFlags::EnableTemperatureCompensation; sns_ot_boiler_status.m_enableCentralHeating2 = Settings.ot_flags & (uint8_t)OpenThermSettingsFlags::EnableCentralHeating2; sns_ot_boiler_status.m_boilerSetpoint = (float)Settings.ot_boiler_setpoint; sns_ot_boiler_status.m_hotWaterSetpoint = (float)Settings.ot_hot_water_setpoint; sns_ot_boiler_status.m_fault_code = 0; sns_ot_boiler_status.m_oem_fault_code = 0; sns_ot_boiler_status.m_oem_diag_code = 0; sns_ot_boiler_status.m_hotWaterSetpoint_read = 0; sns_ot_boiler_status.m_flame_modulation_read = 0; sns_ot_boiler_status.m_boiler_temperature_read = 0; } void ICACHE_RAM_ATTR sns_opentherm_handleInterrupt() { sns_ot_master->handleInterrupt(); } void sns_opentherm_processResponseCallback(unsigned long response, int st) { OpenThermResponseStatus status = (OpenThermResponseStatus)st; AddLog_P2(LOG_LEVEL_DEBUG_MORE, PSTR("[OTH]: Processing response. Status=%s, Response=0x%lX"), sns_ot_master->statusToString(status), response); if (sns_ot_connection_status == OpenThermConnectionStatus::OTC_HANDSHAKE) { return sns_ot_process_handshake(response, st); } switch (status) { case OpenThermResponseStatus::SUCCESS: if (sns_ot_master->isValidResponse(response)) { sns_opentherm_process_success_response(&sns_ot_boiler_status, response); } sns_ot_connection_status = OpenThermConnectionStatus::OTC_READY; break; case OpenThermResponseStatus::INVALID: sns_opentherm_check_retry_request(); sns_ot_connection_status = OpenThermConnectionStatus::OTC_READY; break; // Timeout may indicate not valid/supported command or connection error // In this case we do reconnect. // If this command will timeout multiple times, it will be excluded from the rotation later on // after couple of failed attempts. See sns_opentherm_check_retry_request logic case OpenThermResponseStatus::TIMEOUT: sns_opentherm_check_retry_request(); sns_ot_connection_status = OpenThermConnectionStatus::OTC_DISCONNECTED; break; } } bool sns_opentherm_Init() { if (PinUsed(GPIO_BOILER_OT_RX) && PinUsed(GPIO_BOILER_OT_TX)) { sns_ot_master = new OpenTherm(Pin(GPIO_BOILER_OT_RX), Pin(GPIO_BOILER_OT_TX)); sns_ot_master->begin(sns_opentherm_handleInterrupt, sns_opentherm_processResponseCallback); sns_ot_connection_status = OpenThermConnectionStatus::OTC_CONNECTING; sns_opentherm_init_boiler_status(); return true; } return false; // !warning, sns_opentherm settings are not ready at this point } void sns_opentherm_stat(bool json) { if (!sns_ot_master) { return; } const char *statusStr = sns_opentherm_connection_stat_to_str(sns_ot_connection_status); if (json) { ResponseAppend_P(PSTR(",\"OPENTHERM\":{")); ResponseAppend_P(PSTR("\"conn\":\"%s\","), statusStr); ResponseAppend_P(PSTR("\"settings\":%d,"), Settings.ot_flags); sns_opentherm_dump_telemetry(); ResponseJsonEnd(); #ifdef USE_WEBSERVER } else { WSContentSend_P(PSTR("{s}OpenTherm status{m}%s (0x%X){e}"), statusStr, (int)sns_ot_boiler_status.m_slave_flags); if (sns_ot_connection_status < OpenThermConnectionStatus::OTC_READY) { return; } WSContentSend_P(PSTR("{s}Std/OEM Fault Codes{m}%d / %d{e}"), (int)sns_ot_boiler_status.m_fault_code, (int)sns_ot_boiler_status.m_oem_fault_code); WSContentSend_P(PSTR("{s}OEM Diagnostic Code{m}%d{e}"), (int)sns_ot_boiler_status.m_oem_diag_code); WSContentSend_P(PSTR("{s}Hot Water Setpoint{m}%d{e}"), (int)sns_ot_boiler_status.m_hotWaterSetpoint_read); WSContentSend_P(PSTR("{s}Flame Modulation{m}%d{e}"), (int)sns_ot_boiler_status.m_flame_modulation_read); WSContentSend_P(PSTR("{s}Boiler Temp/Setpnt{m}%d / %d{e}"), (int)sns_ot_boiler_status.m_boiler_temperature_read, (int)sns_ot_boiler_status.m_boilerSetpoint); if (OpenTherm::isCentralHeatingActive(sns_ot_boiler_status.m_slave_raw_status)) { WSContentSend_P(PSTR("{s}Central Heating is ACTIVE{m}{e}")); } if (sns_ot_boiler_status.m_enableHotWater) { WSContentSend_P(PSTR("{s}Hot Water is Enabled{m}{e}")); } if (OpenTherm::isHotWaterActive(sns_ot_boiler_status.m_slave_raw_status)) { WSContentSend_P(PSTR("{s}Hot Water is ACTIVE{m}{e}")); } if (OpenTherm::isFlameOn(sns_ot_boiler_status.m_slave_raw_status)) { WSContentSend_P(PSTR("{s}Flame is ACTIVE{m}{e}")); } if (sns_ot_boiler_status.m_enableCooling) { WSContentSend_P(PSTR("{s}Cooling is Enabled{m}{e}")); } if (OpenTherm::isCoolingActive(sns_ot_boiler_status.m_slave_raw_status)) { WSContentSend_P(PSTR("{s}Cooling is ACTIVE{m}{e}")); } if (OpenTherm::isDiagnostic(sns_ot_boiler_status.m_slave_raw_status)) { WSContentSend_P(PSTR("{s}Diagnostic Indication{m}{e}")); } #endif // USE_WEBSERVER } } void sns_ot_start_handshake() { if (!sns_ot_master) { return; } AddLog_P2(LOG_LEVEL_DEBUG, PSTR("[OTH]: perform handshake")); sns_ot_master->sendRequestAync( OpenTherm::buildRequest(OpenThermMessageType::READ_DATA, OpenThermMessageID::SConfigSMemberIDcode, 0)); sns_ot_connection_status = OpenThermConnectionStatus::OTC_HANDSHAKE; } void sns_ot_process_handshake(unsigned long response, int st) { OpenThermResponseStatus status = (OpenThermResponseStatus)st; if (status != OpenThermResponseStatus::SUCCESS || !sns_ot_master->isValidResponse(response)) { AddLog_P2(LOG_LEVEL_ERROR, PSTR("[OTH]: getSlaveConfiguration failed. Status=%s"), sns_ot_master->statusToString(status)); sns_ot_connection_status = OpenThermConnectionStatus::OTC_DISCONNECTED; return; } AddLog_P2(LOG_LEVEL_DEBUG, PSTR("[OTH]: getLastResponseStatus SUCCESS. Slave Cfg: %lX"), response); sns_ot_boiler_status.m_slave_flags = (response & 0xFF00) >> 8; sns_ot_connection_status = OpenThermConnectionStatus::OTC_READY; } void sns_opentherm_CheckSettings(void) { bool settingsValid = true; settingsValid &= Settings.ot_hot_water_setpoint >= OT_HOT_WATER_MIN; settingsValid &= Settings.ot_hot_water_setpoint <= OT_HOT_WATER_MAX; settingsValid &= Settings.ot_boiler_setpoint >= OT_BOILER_MIN; settingsValid &= Settings.ot_boiler_setpoint <= OT_BOILER_MAX; if (!settingsValid) { Settings.ot_hot_water_setpoint = OT_HOT_WATER_DEFAULT; Settings.ot_boiler_setpoint = OT_BOILER_DEFAULT; Settings.ot_flags = OpenThermSettingsFlags::EnableCentralHeatingOnDiagnostics | OpenThermSettingsFlags::EnableHotWater; } } /*********************************************************************************************\ * Command Processing \*********************************************************************************************/ const char *sns_opentherm_flag_text(uint8_t mode) { switch ((OpenThermSettingsFlags)mode) { case OpenThermSettingsFlags::EnableCentralHeatingOnDiagnostics: return "CHOD"; case OpenThermSettingsFlags::EnableHotWater: return "DHW"; case OpenThermSettingsFlags::EnableCentralHeating: return "CH"; case OpenThermSettingsFlags::EnableCooling: return "COOL"; case OpenThermSettingsFlags::EnableTemperatureCompensation: return "OTC"; case OpenThermSettingsFlags::EnableCentralHeating2: return "CH2"; default: return "?"; } } uint8_t sns_opentherm_parse_flag(char *flag) { if (!strncmp(flag, "CHOD", 4)) { return OpenThermSettingsFlags::EnableCentralHeatingOnDiagnostics; } else if (!strncmp(flag, "COOL", 4)) { return OpenThermSettingsFlags::EnableCooling; } else if (!strncmp(flag, "DHW", 3)) { return OpenThermSettingsFlags::EnableHotWater; } else if (!strncmp(flag, "OTC", 3)) { return OpenThermSettingsFlags::EnableTemperatureCompensation; } else if (!strncmp(flag, "CH2", 3)) { return OpenThermSettingsFlags::EnableCentralHeating2; } else if (!strncmp(flag, "CH", 2)) { return OpenThermSettingsFlags::EnableCentralHeating; } return 0; } uint8_t sns_opentherm_read_flags(char *data, uint32_t len) { uint8_t tokens = 1; for (int i = 0; i < len; ++i) { if (data[i] == ',') { ++tokens; } } uint8_t result = 0; char sub_string[XdrvMailbox.data_len + 1]; for (int i = 1; i <= tokens; ++i) { char *flag = subStr(sub_string, data, ",", i); if (!flag) { break; } result |= sns_opentherm_parse_flag(flag); } return result; } #define D_PRFX_OTHERM "ot_" // set the boiler temperature (CH). Sutable for the PID app. // After restart will use the defaults from the settings #define D_CMND_OTHERM_BOILER_SETPOINT "tboiler" // set hot water (DHW) temperature. Do not write it in the flash memory. // suitable for the temporary changes #define D_CMND_OTHERM_DHW_SETPOINT "twater" // This command will save CH and DHW setpoints into the settings. Those values will be used after system restart // The reason to separate set and save is to reduce flash memory write count, especially if boiler temperature is controlled // by the PID thermostat #define D_CMND_OTHERM_SAVE_SETTINGS "save_setpoints" // Get or set flags // EnableCentralHeatingOnDiagnostics -> CHOD // EnableHotWater -> DHW // EnableCentralHeating -> CH // EnableCooling -> COOL // EnableTemperatureCompensation -> OTC // EnableCentralHeating2 -> CH2 #define D_CMND_OTHERM_FLAGS "flags" // Get/Set boiler status m_enableCentralHeating value. It's equivalent of the EnableCentralHeating settings // flag value, however, this command does not update the settings. // Usefull to buld automations // Please note, if you set it to "0" and EnableCentralHeatingOnDiagnostics is set // boiler will follow the Diagnostics bit and won't turn CH off. When Diagnostics bit cleared, // and "ot_ch" is "1", boiler will keep heating #define D_CMND_SET_CENTRAL_HEATING_ENABLED "ch" const char kOpenThermCommands[] PROGMEM = D_PRFX_OTHERM "|" D_CMND_OTHERM_BOILER_SETPOINT "|" D_CMND_OTHERM_DHW_SETPOINT "|" D_CMND_OTHERM_SAVE_SETTINGS "|" D_CMND_OTHERM_FLAGS "|" D_CMND_SET_CENTRAL_HEATING_ENABLED; void (*const OpenThermCommands[])(void) PROGMEM = { &sns_opentherm_boiler_setpoint_cmd, &sns_opentherm_hot_water_setpoint_cmd, &sns_opentherm_save_settings_cmd, &sns_opentherm_flags_cmd, &sns_opentherm_set_central_heating_cmd}; void sns_opentherm_cmd(void) { } void sns_opentherm_boiler_setpoint_cmd(void) { bool query = strlen(XdrvMailbox.data) == 0; if (!query) { sns_ot_boiler_status.m_boilerSetpoint = atof(XdrvMailbox.data); } ResponseCmndFloat(sns_ot_boiler_status.m_boilerSetpoint, Settings.flag2.temperature_resolution); } void sns_opentherm_hot_water_setpoint_cmd(void) { bool query = strlen(XdrvMailbox.data) == 0; if (!query) { sns_ot_boiler_status.m_hotWaterSetpoint = atof(XdrvMailbox.data); } ResponseCmndFloat(sns_ot_boiler_status.m_hotWaterSetpoint, Settings.flag2.temperature_resolution); } void sns_opentherm_save_settings_cmd(void) { Settings.ot_hot_water_setpoint = (uint8_t)sns_ot_boiler_status.m_hotWaterSetpoint; Settings.ot_boiler_setpoint = (uint8_t)sns_ot_boiler_status.m_boilerSetpoint; ResponseCmndDone(); } void sns_opentherm_flags_cmd(void) { bool query = strlen(XdrvMailbox.data) == 0; if (!query) { // Set flags value Settings.ot_flags = sns_opentherm_read_flags(XdrvMailbox.data, XdrvMailbox.data_len); // Reset boiler status to apply settings sns_opentherm_init_boiler_status(); } bool addComma = false; TasmotaGlobal.mqtt_data[0] = 0; for (int pos = 0; pos < OT_FLAGS_COUNT; ++pos) { int mask = 1 << pos; int mode = Settings.ot_flags & (uint8_t)mask; if (mode > 0) { if (addComma) { snprintf_P(TasmotaGlobal.mqtt_data, sizeof(TasmotaGlobal.mqtt_data), PSTR("%s,"), TasmotaGlobal.mqtt_data); } snprintf_P(TasmotaGlobal.mqtt_data, sizeof(TasmotaGlobal.mqtt_data), PSTR("%s%s"), TasmotaGlobal.mqtt_data, sns_opentherm_flag_text(mode)); addComma = true; } } } void sns_opentherm_set_central_heating_cmd(void) { bool query = strlen(XdrvMailbox.data) == 0; if (!query) { sns_ot_boiler_status.m_enableCentralHeating = atoi(XdrvMailbox.data); } ResponseCmndNumber(sns_ot_boiler_status.m_enableCentralHeating ? 1 : 0); } /*********************************************************************************************\ * Interface \*********************************************************************************************/ bool Xsns69(uint8_t function) { bool result = false; if (FUNC_INIT == function) { if (sns_opentherm_Init()) { sns_opentherm_CheckSettings(); } } if (!sns_ot_master) { return result; } switch (function) { case FUNC_LOOP: sns_ot_master->process(); break; case FUNC_EVERY_100_MSECOND: if (sns_ot_connection_status == OpenThermConnectionStatus::OTC_READY && sns_ot_master->isReady()) { unsigned long request = sns_opentherm_get_next_request(&sns_ot_boiler_status); if (-1 != request) { sns_ot_master->sendRequestAync(request); sns_ot_connection_status = OpenThermConnectionStatus::OTC_INFLIGHT; } } break; case FUNC_EVERY_SECOND: if (sns_ot_connection_status == OpenThermConnectionStatus::OTC_DISCONNECTED) { // If disconnected, wait for the SNS_OT_DISCONNECT_COOLDOWN_SECONDS before the handshake if (sns_ot_disconnect_cooldown == 0) { sns_ot_disconnect_cooldown = SNS_OT_DISCONNECT_COOLDOWN_SECONDS; } else if (--sns_ot_disconnect_cooldown == 0) { sns_ot_connection_status = OpenThermConnectionStatus::OTC_CONNECTING; } } else if (sns_ot_connection_status == OpenThermConnectionStatus::OTC_CONNECTING) { sns_ot_start_handshake(); } break; case FUNC_COMMAND: result = DecodeCommand(kOpenThermCommands, OpenThermCommands); break; case FUNC_JSON_APPEND: sns_opentherm_stat(1); break; #ifdef USE_WEBSERVER case FUNC_WEB_SENSOR: sns_opentherm_stat(0); break; #endif // USE_WEBSERVER } return result; } #endif // USE_OPENTHERM