# JSON value pair description ## Example ``` {"Name":"SDM230","Baud":2400,"Config":"8N1","Address":1,"Function":4,"Voltage":0,"Current":6,"Power":12,"ApparentPower":18,"ReactivePower":24,"Factor":30,"Frequency":70,"Total":342,"ExportActive":0x004A} ``` ## Modbus config parameters ``` Name - Name of energy monitoring device(s) Baud - Baudrate of device modbus interface - optional. default is 9600 Config - Serial config parameters like 8N1 - 8 databits, No parity, 1 stop bit Poll - Time between modbus requests - optional. default is 200 milliseconds Address - Modbus device address entered as decimal (1) or hexadecimal (0x01) or up to three addresses ([1,2,3]) - optional. default = 1 Function - Modbus function code to access registers - optional. default = 4 ``` ## Tasmota default embedded register names ``` Voltage - Voltage register entered as decimal or hexadecimal for one phase (0x0000) or up to three phases ([0x0000,0x0002,0x0004]) or Additional defined parameters Value pair description: {"R":0,"T":0,"F":0} R - Modbus register entered as decimal or hexadecimal for one phase (0x0160) or up to three phases ([0x0160,0x0162,0x0164]) T - Datatype - optional. default is 0 - float: 0 - float 1 = 2-byte signed 2 = 4-byte signed 3 = 2-byte unsigned 4 = 4-byte unsigned 5 = not used 6 = 4-byte signed with swapped words 7 = not used 8 = 4-byte unsigned with swapped words F - Register factor positive for multiplication or negative for division - optional. default is 0 - no action -4 - divide by 10000 -3 - divide by 1000 -2 - divide by 100 -1 - divide by 10 0 - no action 1 - multiply by 10 2 - multiply by 100 3 - multiply by 1000 4 - multiply by 10000 Current - Current register entered as decimal or hexadecimal for one phase (0x0006) or up to three phases ([0x0006,0x0008,0x000A]) or See additional defines like voltage. Power - Active power register entered as decimal or hexadecimal for one phase (0x000C) or up to three phases ([0x000C,0x000E,0x0010]) or See additional defines like voltage. ApparentPower - Apparent power register entered as decimal or hexadecimal for one phase (0x000C) or up to three phases ([0x000C,0x000E,0x0010]) or See additional defines like voltage. ReactivePower - Reactive power register entered as decimal or hexadecimal for one phase (0x0018) or up to three phases ([0x0018,0x001A,0x001C]) or See additional defines like voltage. Factor - Power factor register entered as decimal or hexadecimal for one phase (0x001E) or up to three phases ([0x001E,0x0020,0x0022]) or See additional defines like voltage. Frequency - Frequency register entered as decimal or hexadecimal for one phase (0x0046) or up to three phases ([0x0046,0x0048,0x004A]) or See additional defines like voltage. Total - Total active energy register entered as decimal or hexadecimal for one phase (0x0156) or up to three phases ([0x015A,0x015C,0x015E]) or See additional defines like voltage. ExportActive - Export active energy register entered as decimal or hexadecimal for one phase (0x0160) or up to three phases ([0x0160,0x0162,0x0164]) or See additional defines like voltage. ``` ## Optional user defined registers ``` User - Additional user defined registers Value pair description: "User":{"R":0x0024,"T":0,"F":0,"J":"PhaseAngle","G":"Phase Angle","U":"Deg","D":2} R - Modbus register entered as decimal or hexadecimal for one phase (0x0160) or up to three phases ([0x0160,0x0162,0x0164]) T - Datatype - optional. default is 0 - float: 0 - float 1 = 2-byte signed 2 = 4-byte signed 3 = 2-byte unsigned 4 = 4-byte unsigned 5 = not used 6 = 4-byte signed with swapped words 7 = not used 8 = 4-byte unsigned with swapped words F - Register factor positive for multiplication or negative for division - optional. default is 0 - no action -4 - divide by 10000 -3 - divide by 1000 -2 - divide by 100 -1 - divide by 10 0 - no action 1 - multiply by 10 2 - multiply by 100 3 - multiply by 1000 4 - multiply by 10000 J - JSON register name (preferrably without spaces like "PhaseAngle") - mandatory. It needs to be different from the Tasmota default embedded register names G - GUI register name - optional. If not defined the register will not be shown in the GUI U - GUI unit name - optional. default is none D - Number of decimals for floating point presentation (0 to 20) or a code correspondig to Tasmota resolution command settings: 21 - VoltRes (V) 22 - AmpRes (A) 23 - WattRes (W, VA, VAr) 24 - EnergyRes (kWh, kVAh, kVArh) 25 - FreqRes (Hz) 26 - TempRes (C, F) 27 - HumRes (%) 28 - PressRes (hPa, mmHg) 29 - WeightRes (Kg) ```