diff --git a/Xiaomi-Mi-Desk-Lamp.md b/Xiaomi-Mi-Desk-Lamp.md index 9697b7fb..44da8c44 100644 --- a/Xiaomi-Mi-Desk-Lamp.md +++ b/Xiaomi-Mi-Desk-Lamp.md @@ -13,7 +13,7 @@ At the bottom of the lamp stand there is also a 'Reset' button, which can be pre ## Configuration -Tasmota supports it directly as `Module "Mi Desk Lamp"`. +Tasmota supports it directly as `Module "Mi Desk Lamp"`. Per default it's deactivated in the `my_user_config.h` you need to uncomment `#define ROTARY_V1` for it to appear as a module option in the UI. To configure it as `Generic`, here is the GPIO assignment: - GPIO02: Button (`GPIO_KEY1`) @@ -150,4 +150,4 @@ is situated on your desk, so it's a perfect place for temp+humidity measurements If you want to place the sensor inside the lamp base, then you may need to remove some material from one of the weight panels, and if you choose to place it on the outside (eg. near the base), then a convenient and relatively hidden path for the 3 wires is -above the power jack, just enlarge the hole by 2 mm-s with a file. +above the power jack, just enlarge the hole by 2 mm-s with a file. \ No newline at end of file