diff --git a/Rules.md b/Rules.md index 7a43e1a6..d1f66a77 100644 --- a/Rules.md +++ b/Rules.md @@ -187,13 +187,13 @@ VARx#State | when a the value for a Variable is changed MEMx#State | when a the value for a Persistent Variable is changed | 6.4.1.14 #### Sensors -All connected sensors can be a trigger in the form as they are represented in the teleperiod or Status 8 JSON message. The format is: +All connected sensors can be a trigger in the form as they are represented in the TelePeriod or Status 8 JSON message. The format is: ``` [SensorName]#[ValueName] ``` Example triggers are: -- ``Tele-AM2301#Temperature``triggers on the Teleperiod time for the sensor AM2301. +- ``Tele-AM2301#Temperature``triggers on the TelePeriod time for the sensor AM2301. - ``Dsb18b20#Temperature<20`` whenever the temperature of sensor DSB18B20 is below 20 degrees - ``AM2301-12#Humidity=55.5`` whenever the hunidity of sensor AM2301-12 equals 55.5 % - ``INA219#Current>0.100`` whenever the current drawn is more than 0.1A @@ -204,7 +204,7 @@ Devices using RfReceived (Sonoff Bridge) or IrReceived are also supported based - ``IrReceived#Data=801`` whenever an IR signal for a RC5 remote control button 1 is received (6.1.0) - ``RfReceived#RfKey=4`` whenever the Sonoff Bridge receives a recognized Rf signal (6.1.0) -To trigger on a sensor at Teleperiod time only you may prefix the sensor with the word ``tele-`` to distinguish it from the above shown trigger. See example 5 below. +To trigger on a sensor at TelePeriod time only you may prefix the sensor with the word ``tele-`` to distinguish it from the above shown trigger. See example 5 below. [BackToTop](https://github.com/arendst/Sonoff-Tasmota/wiki/Rules#summary) @@ -606,7 +606,7 @@ Inital config on console: * `SwitchMode1 3` <- Use the switch1 as pushbutton (It will allow us to disable the link between the button and the relay by inserting a rule to dictate what the pushbutton will do - **NOTE: Until rules are created the pushbutton will still control the relay!**) * `Rule 1 ` <- turn on rules * `Rule 4` <- turn off one-shot rule -* `teleperiod 60` <- check temp every minute +* `TelePeriod 60` <- check temp every minute * `SetOption26 1` <- use power1 on mqtt messages * `SetOption0 0` <- dont save relay status on eeprom * `poweronstate 0` <- start all relays off @@ -658,9 +658,9 @@ To get the status: Everything together: -INITIAL CONFIG: (To note RuleTimer1 must be greater that teleperiod for expected results) +INITIAL CONFIG: (To note RuleTimer1 must be greater that TelePeriod for expected results) -`backlog SwitchMode1 3; Rule 1; Rule 4; teleperiod 60; SetOption26 1; SetOption0 0; poweronstate 0; mem1 0; mem2 25; mem3 23; var1 0` +`backlog SwitchMode1 3; Rule 1; Rule 4; TelePeriod 60; SetOption26 1; SetOption0 0; poweronstate 0; mem1 0; mem2 25; mem3 23; var1 0` RULES: