2020-01-05 00:06:30 +00:00
|
|
|
/*
|
|
|
|
xnrg_13_fif_le01mr.ino - F&F LE-01MR energy meter with Modbus interface - support for Tasmota
|
|
|
|
|
2021-01-01 12:44:04 +00:00
|
|
|
Copyright (C) 2021 Przemyslaw Wistuba
|
2020-01-05 00:06:30 +00:00
|
|
|
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
|
|
it under the terms of the GNU General Public License as published by
|
|
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
|
|
(at your option) any later version.
|
|
|
|
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
|
|
GNU General Public License for more details.
|
|
|
|
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
*/
|
2020-02-10 14:18:11 +00:00
|
|
|
|
2020-01-05 00:06:30 +00:00
|
|
|
#ifdef USE_ENERGY_SENSOR
|
|
|
|
#ifdef USE_LE01MR
|
|
|
|
/*********************************************************************************************\
|
2020-02-10 14:18:11 +00:00
|
|
|
* F&F LE-01MR - This is a single phase energy meter with rs485 modbus interface
|
2020-01-05 00:06:30 +00:00
|
|
|
* (and bidirectional energy counting - enabled by RS485).
|
|
|
|
* It measure: Active energy imported AE+ [kWh] , Reactive energy imported RE+ [kvarh],
|
|
|
|
* Voltage V [V], Current I [A], Frequency F [Hz], power factor (aka "cos-phi"),
|
2020-01-23 15:13:25 +00:00
|
|
|
* Active power P [kW], Reactive power Q [kVAr], Apparent power S [kVA],
|
2020-02-10 14:18:11 +00:00
|
|
|
* *Active energy exported AE- [kWh] (when meter is switched to bi-directional counting then
|
2020-01-05 00:06:30 +00:00
|
|
|
* reactive energy imported register contains value of Active energy exported).
|
|
|
|
*
|
|
|
|
* Meter descriptions at manufacturer page (english version have some description errors):
|
|
|
|
* EN: https://www.fif.com.pl/en/usage-electric-power-meters/517-electricity-consumption-meter-le-01mr.html
|
|
|
|
* PL: https://www.fif.com.pl/pl/liczniki-zuzycia-energii-elektrycznej/517-licznik-zuzycia-energii-le-01mr.html
|
2020-02-10 14:18:11 +00:00
|
|
|
*
|
|
|
|
* Note about communication settings: The meter must be reconfigured to use baudrate 2400 (or 9600) *without*
|
|
|
|
* parity bit - by default the meter is configured to 9600 8E1
|
|
|
|
* (Frame format: "EVEN 1") . To make those changes, use LE-Config
|
2020-01-23 15:13:25 +00:00
|
|
|
* software (can be found in download tab in product page - link above)
|
|
|
|
* and USB-RS485 dongle (those cheap ~2$ from ali works fine)
|
2020-02-10 14:18:11 +00:00
|
|
|
*
|
2020-01-05 00:06:30 +00:00
|
|
|
* Register descriptions (not all, only those that are being read):
|
2020-02-10 14:18:11 +00:00
|
|
|
*
|
2020-01-05 00:06:30 +00:00
|
|
|
* /----------------------------------- Register address
|
|
|
|
* | /-------------------------- Registers count
|
|
|
|
* | | /---------------------- Datatype and size
|
|
|
|
* | | | /----------------- Resolution (or multiplier)
|
|
|
|
* | | | | /---------- Unit
|
|
|
|
* | | | | | /---- Description
|
|
|
|
* 0x0130 1 U16 0.01 Hz Frequency
|
|
|
|
* 0x0131 1 U16 0.01 V Voltage
|
|
|
|
* 0x0139 2 U32 0.001 A Current
|
|
|
|
* 0x0140 2 U32 0.001 kW Active power
|
|
|
|
* 0x0148 2 U32 0.001 kvar Reactive power
|
|
|
|
* 0x0150 2 U32 0.001 kVA Apparent power
|
|
|
|
* 0x0158 1 S16 0.001 - Power factor
|
|
|
|
* 0xA000 2 U32 0.01 kWh Active energy imported
|
|
|
|
* 0xA01E 2 U32 0.01 kvarh Reactive energy imported
|
2020-02-10 14:18:11 +00:00
|
|
|
*
|
|
|
|
* Datatype: S = signed int, U = unsigend int,
|
|
|
|
* U32 - the first (lower) register contains high word,
|
2020-01-05 00:06:30 +00:00
|
|
|
* second register contains lower word of 32bit dword:
|
2020-02-10 14:18:11 +00:00
|
|
|
* value_32bit = (register+0)<<16 | (register+1);
|
2020-01-05 00:06:30 +00:00
|
|
|
* /or/ val32bit = (reg+0)*65536 + (reg+1);
|
2020-02-10 14:18:11 +00:00
|
|
|
*
|
|
|
|
* Note about MQTT/JSON: In fields "ENERGY.TotalActive" and "ENERGY.TotalReactive" there are
|
2020-01-23 15:13:25 +00:00
|
|
|
* counters values directly from the meter (without Tasmota calculation,
|
|
|
|
* energy used calculated by Tasmota is in Total/Today fields ).
|
|
|
|
* Filed "ENERGY.Period" is always zero.
|
2020-01-05 00:06:30 +00:00
|
|
|
\*********************************************************************************************/
|
|
|
|
|
|
|
|
#define XNRG_13 13
|
|
|
|
|
|
|
|
// can be user defined in my_user_config.h
|
|
|
|
#ifndef LE01MR_SPEED
|
|
|
|
#define LE01MR_SPEED 2400 // default LE01MR Modbus speed
|
|
|
|
#endif
|
|
|
|
// can be user defined in my_user_config.h
|
|
|
|
#ifndef LE01MR_ADDR
|
|
|
|
#define LE01MR_ADDR 1 // default LE01MR Modbus address
|
|
|
|
#endif
|
|
|
|
|
|
|
|
#include <TasmotaModbus.h>
|
|
|
|
TasmotaModbus *FifLEModbus;
|
|
|
|
|
|
|
|
const uint8_t le01mr_table_sz = 9;
|
|
|
|
|
|
|
|
const uint16_t le01mr_register_addresses[] {
|
|
|
|
// IDX (reg count/datatype) [unit]
|
|
|
|
0x0130, // 00 . LE01MR_FREQUENCY (1/U16) [Hz]
|
|
|
|
0x0131, // 01 . LE01MR_VOLTAGE (1/U16) [V]
|
2020-02-10 14:18:11 +00:00
|
|
|
0x0158, // 02 . LE01MR_POWER_FACTOR (1/S16)
|
2020-01-05 00:06:30 +00:00
|
|
|
0x0139, // 03 . LE01MR_CURRENT (2/U32) [A]
|
|
|
|
0x0140, // 04 . LE01MR_ACTIVE_POWER (2/U32) [kW]
|
|
|
|
0x0148, // 05 . LE01MR_REACTIVE_POWER (2/U32) [kvar]
|
|
|
|
0x0150, // 06 . LE01MR_APPARENT_POWER (2/U32) [kVA]
|
|
|
|
0xA000, // 07 . LE01MR_TOTAL_ACTIVE_ENERGY (2/U32) [kWh]
|
|
|
|
0xA01E // 08 . LE01MR_TOTAL_REACTIVE_ENERGY (2/U32) [kvarh]
|
|
|
|
};
|
|
|
|
|
|
|
|
struct LE01MR {
|
|
|
|
float total_active = 0;
|
|
|
|
float total_reactive = 0;
|
|
|
|
uint8_t read_state = 0;
|
|
|
|
uint8_t send_retry = 0;
|
|
|
|
uint8_t start_address_count = le01mr_table_sz;
|
|
|
|
} Le01mr;
|
|
|
|
|
|
|
|
/*********************************************************************************************/
|
|
|
|
|
|
|
|
void FifLEEvery250ms(void)
|
|
|
|
{
|
|
|
|
bool data_ready = FifLEModbus->ReceiveReady();
|
|
|
|
|
|
|
|
if (data_ready) {
|
|
|
|
uint8_t buffer[14]; // At least 9
|
|
|
|
uint8_t reg_count = 2;
|
2020-01-05 13:32:35 +00:00
|
|
|
if (Le01mr.read_state < 3) {
|
2020-01-05 00:06:30 +00:00
|
|
|
reg_count=1;
|
|
|
|
}
|
|
|
|
|
|
|
|
uint32_t error = FifLEModbus->ReceiveBuffer(buffer, reg_count);
|
|
|
|
|
|
|
|
AddLogBuffer(LOG_LEVEL_DEBUG_MORE, buffer, FifLEModbus->ReceiveCount());
|
|
|
|
|
|
|
|
if (error) {
|
2021-01-23 16:10:06 +00:00
|
|
|
AddLog(LOG_LEVEL_DEBUG, PSTR("FiF-LE: LE01MR Modbus error %d"), error);
|
2020-01-05 00:06:30 +00:00
|
|
|
} else {
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->data_valid[0] = 0;
|
2020-01-05 00:06:30 +00:00
|
|
|
|
2020-06-18 15:05:55 +01:00
|
|
|
// CA=Client Address, FC=Function Code, BC=Byte Count, B3..B0=Data byte, Ch Cl = crc16 checksum
|
2020-01-05 00:06:30 +00:00
|
|
|
// U32 registers:
|
|
|
|
// 00 01 02 03 04 05 06 07 08
|
2020-06-18 15:05:55 +01:00
|
|
|
// CA FC BC B3 B2 B1 B0 Cl Ch
|
2020-01-05 00:06:30 +00:00
|
|
|
// 01 03 04 00 00 00 72 7A 16 = REG[B3..B2=0x0139,B1..B0=0x013A] 114 = 0.114 A
|
|
|
|
// 01 03 04 00 00 00 B0 FB 87 = REG[B3..B2=0xA01E,B1..B0=0xA01F] 176 = 1.76 kvarh
|
|
|
|
// U16/S16 registers:
|
|
|
|
// 00 01 02 03 04 05 06
|
2020-06-18 15:05:55 +01:00
|
|
|
// CA FC BC B1 B0 Cl Ch
|
2020-01-05 00:06:30 +00:00
|
|
|
// 01 03 02 5B 02 02 B5 = REG[B1..B0=0x0131] 23298 = 232.98 V
|
|
|
|
// 01 03 02 03 E8 B8 FA = REG[B1..B0=0x0158] 1000 = 1.000 (power factor)
|
|
|
|
// there are 3 data types used:
|
|
|
|
// U16 - uint16_t
|
|
|
|
// U32 - uint32_t
|
|
|
|
// S16 - int16_t
|
|
|
|
// everything drop into uint32 value, but depending on register ther will be 2 or 4 bytes
|
|
|
|
uint32_t value_buff = 0;
|
2020-02-10 14:18:11 +00:00
|
|
|
// for register table items 0..2 use 2 bytes (U16)
|
|
|
|
if (Le01mr.read_state >= 0 && Le01mr.read_state < 3) { //
|
2020-01-05 00:06:30 +00:00
|
|
|
value_buff = ((uint32_t)buffer[3])<<8 | buffer[4];
|
|
|
|
} else {
|
|
|
|
value_buff = ((uint32_t)buffer[3])<<24 | ((uint32_t)buffer[4])<<16 | ((uint32_t)buffer[5])<<8 | buffer[6];
|
|
|
|
}
|
|
|
|
|
|
|
|
switch(Le01mr.read_state) {
|
|
|
|
case 0:
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->frequency[0] = value_buff * 0.01f; // 5000 => 50.00
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
case 1:
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->voltage[0] = value_buff * 0.01f; // 23298 => 232.98 V
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
case 2:
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->power_factor[0] = ((int16_t)value_buff) * 0.001f; // 1000 => 1.000 //note: I never saw this negative...
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
case 3:
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->current[0] = value_buff * 0.001f; // 114 => 0.114 A
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
2020-02-10 14:18:11 +00:00
|
|
|
|
2020-01-05 00:06:30 +00:00
|
|
|
case 4:
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->active_power[0] = value_buff * 1.0f; // P [W]
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
case 5:
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->reactive_power[0] = value_buff * 1.0f; // Q [var]
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
case 6:
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->apparent_power[0] = value_buff * 1.0f; // S [VA]
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
case 7:
|
2023-01-24 15:54:03 +00:00
|
|
|
Energy->import_active[0] = value_buff * 0.01f; // [kWh]
|
|
|
|
Le01mr.total_active = Energy->import_active[0]; // Useless
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
case 8:
|
2020-01-05 13:32:35 +00:00
|
|
|
Le01mr.total_reactive = value_buff * 0.01f; // [kvarh] 176 => 1.76
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
}
|
|
|
|
|
|
|
|
Le01mr.read_state++;
|
|
|
|
if (Le01mr.read_state == Le01mr.start_address_count) {
|
|
|
|
Le01mr.read_state = 0;
|
|
|
|
|
2021-10-02 17:29:05 +01:00
|
|
|
EnergyUpdateTotal();
|
2020-01-05 00:06:30 +00:00
|
|
|
}
|
|
|
|
}
|
|
|
|
} // end data ready
|
|
|
|
|
|
|
|
if (0 == Le01mr.send_retry || data_ready) {
|
|
|
|
uint8_t reg_count = 2;
|
|
|
|
|
|
|
|
Le01mr.send_retry = 5;
|
|
|
|
// some registers are 1reg in size
|
2020-01-05 13:32:35 +00:00
|
|
|
if (Le01mr.read_state < 3) reg_count=1;
|
2020-01-05 00:06:30 +00:00
|
|
|
// send request
|
|
|
|
FifLEModbus->Send(LE01MR_ADDR, 0x03, le01mr_register_addresses[Le01mr.read_state], reg_count);
|
|
|
|
} else {
|
|
|
|
Le01mr.send_retry--;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
void FifLESnsInit(void)
|
|
|
|
{
|
2022-12-03 11:33:42 +00:00
|
|
|
FifLEModbus = new TasmotaModbus(Pin(GPIO_LE01MR_RX), Pin(GPIO_LE01MR_TX), Pin(GPIO_NRG_MBS_TX_ENA));
|
2020-01-05 00:06:30 +00:00
|
|
|
uint8_t result = FifLEModbus->Begin(LE01MR_SPEED);
|
|
|
|
if (result) {
|
|
|
|
if (2 == result) { ClaimSerial(); }
|
|
|
|
} else {
|
2020-10-30 11:29:48 +00:00
|
|
|
TasmotaGlobal.energy_driver = ENERGY_NONE;
|
2020-01-05 00:06:30 +00:00
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
void FifLEDrvInit(void)
|
|
|
|
{
|
2020-04-27 11:54:07 +01:00
|
|
|
if (PinUsed(GPIO_LE01MR_RX) && PinUsed(GPIO_LE01MR_TX)) {
|
2020-10-30 11:29:48 +00:00
|
|
|
TasmotaGlobal.energy_driver = XNRG_13;
|
2020-01-05 00:06:30 +00:00
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
void FifLEReset(void)
|
|
|
|
{
|
|
|
|
Le01mr.total_active = 0;
|
2020-01-05 18:51:12 +00:00
|
|
|
Le01mr.total_reactive = 0;
|
2020-01-05 00:06:30 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
#ifdef USE_WEBSERVER
|
|
|
|
const char HTTP_ENERGY_LE01MR[] PROGMEM =
|
2020-01-05 18:51:12 +00:00
|
|
|
"{s}" D_TOTAL_ACTIVE "{m}%s " D_UNIT_KILOWATTHOUR "{e}"
|
|
|
|
"{s}" D_TOTAL_REACTIVE "{m}%s " D_UNIT_KWARH "{e}"
|
|
|
|
;
|
2020-01-05 00:06:30 +00:00
|
|
|
#endif // USE_WEBSERVER
|
|
|
|
|
2022-03-15 16:19:34 +00:00
|
|
|
/*
|
|
|
|
void FifLEShow(bool json) {
|
2020-01-05 00:06:30 +00:00
|
|
|
char total_reactive_chr[FLOATSZ];
|
2021-06-11 17:14:12 +01:00
|
|
|
dtostrfd(Le01mr.total_reactive, Settings->flag2.energy_resolution, total_reactive_chr);
|
2020-01-05 18:51:12 +00:00
|
|
|
char total_active_chr[FLOATSZ];
|
2021-06-11 17:14:12 +01:00
|
|
|
dtostrfd(Le01mr.total_active, Settings->flag2.energy_resolution, total_active_chr);
|
2020-01-05 18:51:12 +00:00
|
|
|
|
2020-01-05 00:06:30 +00:00
|
|
|
if (json) {
|
2020-01-05 18:51:12 +00:00
|
|
|
ResponseAppend_P(PSTR(",\"" D_JSON_TOTAL_ACTIVE "\":%s,\"" D_JSON_TOTAL_REACTIVE "\":%s"),
|
|
|
|
total_active_chr, total_reactive_chr);
|
2020-01-05 00:06:30 +00:00
|
|
|
#ifdef USE_WEBSERVER
|
|
|
|
} else {
|
2020-01-05 18:51:12 +00:00
|
|
|
WSContentSend_PD(HTTP_ENERGY_LE01MR, total_active_chr, total_reactive_chr);
|
2020-01-05 00:06:30 +00:00
|
|
|
#endif // USE_WEBSERVER
|
|
|
|
}
|
|
|
|
}
|
2022-03-15 16:19:34 +00:00
|
|
|
*/
|
|
|
|
|
|
|
|
void FifLEShow(bool json) {
|
2022-10-11 10:10:47 +01:00
|
|
|
char value_chr[GUISZ];
|
|
|
|
char value2_chr[GUISZ];
|
2022-03-15 16:19:34 +00:00
|
|
|
|
|
|
|
if (json) {
|
|
|
|
ResponseAppend_P(PSTR(",\"" D_JSON_TOTAL_ACTIVE "\":%s,\"" D_JSON_TOTAL_REACTIVE "\":%s"),
|
|
|
|
EnergyFormat(value_chr, &Le01mr.total_active, Settings->flag2.energy_resolution),
|
|
|
|
EnergyFormat(value2_chr, &Le01mr.total_reactive, Settings->flag2.energy_resolution));
|
|
|
|
#ifdef USE_WEBSERVER
|
|
|
|
} else {
|
|
|
|
WSContentSend_PD(HTTP_ENERGY_LE01MR, WebEnergyFormat(value_chr, &Le01mr.total_active, Settings->flag2.energy_resolution),
|
|
|
|
WebEnergyFormat(value2_chr, &Le01mr.total_reactive, Settings->flag2.energy_resolution));
|
|
|
|
|
|
|
|
#endif // USE_WEBSERVER
|
|
|
|
}
|
|
|
|
}
|
2020-01-05 00:06:30 +00:00
|
|
|
|
|
|
|
/*********************************************************************************************\
|
|
|
|
* Interface
|
|
|
|
\*********************************************************************************************/
|
|
|
|
|
2022-11-11 09:44:56 +00:00
|
|
|
bool Xnrg13(uint32_t function)
|
2020-01-05 00:06:30 +00:00
|
|
|
{
|
|
|
|
bool result = false;
|
|
|
|
|
|
|
|
switch (function) {
|
|
|
|
case FUNC_EVERY_250_MSECOND:
|
2020-10-30 11:45:34 +00:00
|
|
|
FifLEEvery250ms();
|
2020-01-05 00:06:30 +00:00
|
|
|
break;
|
|
|
|
case FUNC_JSON_APPEND:
|
|
|
|
FifLEShow(1);
|
|
|
|
break;
|
|
|
|
#ifdef USE_WEBSERVER
|
2022-03-15 16:19:34 +00:00
|
|
|
#ifdef USE_ENERGY_COLUMN_GUI
|
|
|
|
case FUNC_WEB_COL_SENSOR:
|
2022-03-26 15:58:44 +00:00
|
|
|
#else // not USE_ENERGY_COLUMN_GUI
|
2020-01-05 00:06:30 +00:00
|
|
|
case FUNC_WEB_SENSOR:
|
2022-03-26 15:58:44 +00:00
|
|
|
#endif // USE_ENERGY_COLUMN_GUI
|
2020-01-05 00:06:30 +00:00
|
|
|
FifLEShow(0);
|
|
|
|
break;
|
|
|
|
#endif // USE_WEBSERVER
|
|
|
|
case FUNC_ENERGY_RESET:
|
|
|
|
FifLEReset();
|
|
|
|
break;
|
|
|
|
case FUNC_INIT:
|
|
|
|
FifLESnsInit();
|
|
|
|
break;
|
|
|
|
case FUNC_PRE_INIT:
|
|
|
|
FifLEDrvInit();
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
|
|
|
#endif // USE_LE01MR
|
|
|
|
#endif // USE_ENERGY_SENSOR
|