Update changelogs

This commit is contained in:
Theo Arends 2024-10-25 17:27:39 +02:00
parent 41442a54ce
commit 0f2b3b1898
4 changed files with 8 additions and 3 deletions

View File

@ -16,6 +16,8 @@ All notable changes to this project will be documented in this file.
- Support for Shelly DALI Dimmer Gen3 (See tips and template in file xdrv_75_dali.ino) - Support for Shelly DALI Dimmer Gen3 (See tips and template in file xdrv_75_dali.ino)
- HASPmota `haspmota.get_pages()` to get the sorted list of pages (#22358) - HASPmota `haspmota.get_pages()` to get the sorted list of pages (#22358)
- Support for US AQI and EPA AQI in PMS5003x sensors (#22294) - Support for US AQI and EPA AQI in PMS5003x sensors (#22294)
- HLK-LD2410 Engineering mode (#21880)
- Support for HLK-LD2410S 24GHz smart wave motion sensor (#22253)
### Breaking Changed ### Breaking Changed

View File

@ -122,7 +122,9 @@ The latter links can be used for OTA upgrades too like ``OtaUrl https://ota.tasm
- DALI command `DaliTarget` to set light control broadcast, group number or gear number - DALI command `DaliTarget` to set light control broadcast, group number or gear number
- DALI inverted signal configuration using GPIO DALI RX_i/TX_i - DALI inverted signal configuration using GPIO DALI RX_i/TX_i
- Support for Shelly DALI Dimmer Gen3 (See tips and template in file xdrv_75_dali.ino) - Support for Shelly DALI Dimmer Gen3 (See tips and template in file xdrv_75_dali.ino)
- Support for HLK-LD2410S 24GHz smart wave motion sensor [#22253](https://github.com/arendst/Tasmota/issues/22253)
- Support for US AQI and EPA AQI in PMS5003x sensors [#22294](https://github.com/arendst/Tasmota/issues/22294) - Support for US AQI and EPA AQI in PMS5003x sensors [#22294](https://github.com/arendst/Tasmota/issues/22294)
- HLK-LD2410 Engineering mode [#21880](https://github.com/arendst/Tasmota/issues/21880)
- Mitsubishi Electric HVAC Operation time for MiElHVAC [#22334](https://github.com/arendst/Tasmota/issues/22334) - Mitsubishi Electric HVAC Operation time for MiElHVAC [#22334](https://github.com/arendst/Tasmota/issues/22334)
- Mitsubishi Electric HVAC Outdoor Temperature for MiElHVAC [#22345](https://github.com/arendst/Tasmota/issues/22345) - Mitsubishi Electric HVAC Outdoor Temperature for MiElHVAC [#22345](https://github.com/arendst/Tasmota/issues/22345)
- Mitsubishi Electric HVAC Compressor Frequency for MiElHVAC [#22347](https://github.com/arendst/Tasmota/issues/22347) - Mitsubishi Electric HVAC Compressor Frequency for MiElHVAC [#22347](https://github.com/arendst/Tasmota/issues/22347)

View File

@ -194,7 +194,7 @@ typedef union { // Restricted by MISRA-C Rule 18.4 bu
uint32_t neopool_outputsensitive : 1; // bit 11 (v13.2.0.1) - SetOption157 - (NeoPool) Output sensitive data (1) uint32_t neopool_outputsensitive : 1; // bit 11 (v13.2.0.1) - SetOption157 - (NeoPool) Output sensitive data (1)
uint32_t mqtt_disable_modbus : 1; // bit 12 (v13.3.0.5) - SetOption158 - (MQTT) Disable publish ModbusReceived MQTT messages (1), you must use event trigger rules instead uint32_t mqtt_disable_modbus : 1; // bit 12 (v13.3.0.5) - SetOption158 - (MQTT) Disable publish ModbusReceived MQTT messages (1), you must use event trigger rules instead
uint32_t counter_both_edges : 1; // bit 13 (v13.3.0.5) - SetOption159 - (Counter) Enable counting on both rising and falling edge (1) uint32_t counter_both_edges : 1; // bit 13 (v13.3.0.5) - SetOption159 - (Counter) Enable counting on both rising and falling edge (1)
uint32_t ld2410_use_pin : 1; // bit 14 (development) - SetOption160 - (LD2410) Disable generate moving event by sensor report - use LD2410 out pin for events (1) uint32_t ld2410_use_pin : 1; // bit 14 (v14.3.0.2) - SetOption160 - (LD2410) Disable generate moving event by sensor report - use LD2410 out pin for events (1)
uint32_t spare15 : 1; // bit 15 uint32_t spare15 : 1; // bit 15
uint32_t spare16 : 1; // bit 16 uint32_t spare16 : 1; // bit 16
uint32_t spare17 : 1; // bit 17 uint32_t spare17 : 1; // bit 17

View File

@ -215,7 +215,8 @@ a_setoption = [[
"(NeoPool) Output sensitive data (1)", "(NeoPool) Output sensitive data (1)",
"(MQTT) Disable publish ModbusReceived MQTT messages (1), you must use event trigger rules instead", "(MQTT) Disable publish ModbusReceived MQTT messages (1), you must use event trigger rules instead",
"(Counter) Enable counting on both rising and falling edge (1)", "(Counter) Enable counting on both rising and falling edge (1)",
"","", "(LD2410) Disable generate moving event by sensor report - use LD2410 out pin for events (1)",
"",
"","","","", "","","","",
"","","","", "","","","",
"","","","", "","","","",
@ -339,7 +340,7 @@ else:
obj = json.load(fp) obj = json.load(fp)
def StartDecode(): def StartDecode():
print ("\n*** decode-status.py v14.2.0.4 by Theo Arends and Jacek Ziolkowski ***") print ("\n*** decode-status.py v14.3.0.2 by Theo Arends and Jacek Ziolkowski ***")
# print("Decoding\n{}".format(obj)) # print("Decoding\n{}".format(obj))