mirror of https://github.com/arendst/Tasmota.git
Merge pull request #15973 from mbezuidenhout/bugfix/iem3000
iem3xxx series energy sensor fixes
This commit is contained in:
commit
102d350c82
|
@ -1,7 +1,7 @@
|
|||
/*
|
||||
xnrg_16_iem3000.ino - Schneider Electric iEM3000 series Modbus energy meter support for Tasmota
|
||||
|
||||
Copyright (C) 2021 Marius Bezuidenhout
|
||||
Copyright (C) 2022 Marius Bezuidenhout
|
||||
|
||||
This program is free software: you can redistribute it and/or modify
|
||||
it under the terms of the GNU General Public License as published by
|
||||
|
@ -47,22 +47,17 @@ const uint16_t Iem3000_start_addresses[] {
|
|||
0x0bd3, // 3 . IEM3000_L1_VOLTAGE (2/Float32) [V] Voltage L1–N
|
||||
0x0bd5, // 4 . IEM3000_L2_VOLTAGE (2/Float32) [V] Voltage L2–N
|
||||
0x0bd7, // 5 . IEM3000_L3_VOLTAGE (2/Float32) [V] Voltage L3–N
|
||||
0x0bed, // 6 . IEM3000_P1_POWER (2/Float32) [KW] Active Power Phase 1
|
||||
0x0bef, // 7 . IEM3000_P2_POWER (2/Float32) [KW] Active Power Phase 2
|
||||
0x0bf1, // 8 . IEM3000_P3_POWER (2/Float32) [KW] Active Power Phase 3
|
||||
0x0bed, // 6 . IEM3000_P1_POWER (2/Float32) [kW] Active Power Phase 1
|
||||
0x0bef, // 7 . IEM3000_P2_POWER (2/Float32) [kW] Active Power Phase 2
|
||||
0x0bf1, // 8 . IEM3000_P3_POWER (2/Float32) [kW] Active Power Phase 3
|
||||
0x0c25, // 9 . IEM3000_FREQUENCY (2/Float32) [Hz] Frequency
|
||||
#ifdef IEM3000_IEM3155
|
||||
0xb02b, // 10 . IEM3000_TOTAL_ACTIVE (2/Float32) [Wh] Total Active Energy Import
|
||||
#else
|
||||
0xb02b, // 10 . IEM3000_TOTAL_ACTIVE (4/Int64) [Wh] Total Active Energy Import
|
||||
#endif
|
||||
0x0dbd, // 10 . IEM3000_L1_IMPORT (4/Int64) [Wh] Active Energy Import Phase 1
|
||||
0x0dc1, // 11 . IEM3000_L1_IMPORT (4/Int64) [Wh] Active Energy Import Phase 1
|
||||
0x0dc5, // 12 . IEM3000_L1_IMPORT (4/Int64) [Wh] Active Energy Import Phase 1
|
||||
0x0c83, // 13 . IEM3000_IMPORT (4/Int64) [Wh] Total Active Energy Import
|
||||
};
|
||||
|
||||
#ifdef IEM3000_IEM3155
|
||||
#define FLOAT_ParamLimit 11
|
||||
#else
|
||||
#define FLOAT_ParamLimit 10
|
||||
#endif
|
||||
|
||||
struct IEM3000 {
|
||||
uint8_t read_state = 0;
|
||||
|
@ -137,27 +132,15 @@ void IEM3000Every250ms(void)
|
|||
break;
|
||||
|
||||
case 6:
|
||||
#ifdef IEM3000_IEM3155
|
||||
Energy.active_power[0] = value*1000;
|
||||
#else
|
||||
Energy.active_power[0] = value;
|
||||
#endif
|
||||
break;
|
||||
|
||||
case 7:
|
||||
#ifdef IEM3000_IEM3155
|
||||
Energy.active_power[1] = value*1000;
|
||||
#else
|
||||
Energy.active_power[1] = value;
|
||||
#endif
|
||||
break;
|
||||
|
||||
case 8:
|
||||
#ifdef IEM3000_IEM3155
|
||||
Energy.active_power[2] = value*1000;
|
||||
#else
|
||||
Energy.active_power[2] = value;
|
||||
#endif
|
||||
break;
|
||||
|
||||
case 9:
|
||||
|
@ -165,11 +148,18 @@ void IEM3000Every250ms(void)
|
|||
break;
|
||||
|
||||
case 10:
|
||||
#ifdef IEM3000_IEM3155
|
||||
Energy.import_active[0] = value;
|
||||
#else
|
||||
Energy.import_active[0] = value64 * 0.001f; // 1125 => 1.125
|
||||
#endif
|
||||
break;
|
||||
|
||||
case 11:
|
||||
Energy.import_active[1] = value;
|
||||
break;
|
||||
|
||||
case 12:
|
||||
Energy.import_active[2] = value;
|
||||
break;
|
||||
|
||||
case 13:
|
||||
EnergyUpdateTotal();
|
||||
break;
|
||||
}
|
||||
|
|
Loading…