add: include EmergencyState in Thermostat sensor json payload (#18344)

This commit is contained in:
Paul Blacknell 2023-04-06 08:50:37 +01:00 committed by GitHub
parent 864c60c579
commit 1be4d15f65
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
1 changed files with 6 additions and 3 deletions

View File

@ -76,7 +76,6 @@
#define D_CMND_TIMESENSLOSTSET "TimeSensLostSet"
#define D_CMND_DIAGNOSTICMODESET "DiagnosticModeSet"
#define D_CMND_CTRDUTYCYCLEREAD "CtrDutyCycleRead"
#define D_CMND_CONTROLMETHOD "ControlMethod"
#define D_CMND_ENABLEOUTPUTSET "EnableOutputSet"
enum ThermostatModes { THERMOSTAT_OFF, THERMOSTAT_AUTOMATIC_OP, THERMOSTAT_MANUAL_OP, THERMOSTAT_MODES_MAX };
@ -176,7 +175,7 @@ const char kThermostatCommands[] PROGMEM = "|" D_CMND_THERMOSTATMODESET "|" D_CM
D_CMND_TIMEMINACTIONSET "|" D_CMND_TIMEMINTURNOFFACTIONSET "|" D_CMND_TEMPRUPDELTINSET "|" D_CMND_TEMPRUPDELTOUTSET "|"
D_CMND_TIMERAMPUPMAXSET "|" D_CMND_TIMERAMPUPCYCLESET "|" D_CMND_TEMPRAMPUPPIACCERRSET "|" D_CMND_TIMEPIPROPORTREAD "|"
D_CMND_TIMEPIINTEGRREAD "|" D_CMND_TIMESENSLOSTSET "|" D_CMND_DIAGNOSTICMODESET "|" D_CMND_CTRDUTYCYCLEREAD "|"
D_CMND_ENABLEOUTPUTSET "|" D_CMND_CONTROLMETHOD;
D_CMND_ENABLEOUTPUTSET;
void (* const ThermostatCommand[])(void) PROGMEM = {
&CmndThermostatModeSet, &CmndClimateModeSet, &CmndTempFrostProtectSet, &CmndControllerModeSet, &CmndInputSwitchSet,
@ -2048,6 +2047,9 @@ const char HTTP_THERMOSTAT_HL[] PROGMEM = "{s}<hr>{m}<hr>{e}";
#endif // USE_WEBSERVER
#define D_THERMOSTAT_JSON_NAME_CONTROL_METHOD "ControlMethod"
#define D_THERMOSTAT_JSON_NAME_EMERGENCY_STATE "EmergencyState"
void ThermostatShow(uint8_t ctr_output, bool json)
{
if (json) {
@ -2056,7 +2058,8 @@ void ThermostatShow(uint8_t ctr_output, bool json)
ResponseAppend_P(PSTR("%s\"%s\":%i"), "", D_CMND_THERMOSTATMODESET, Thermostat[ctr_output].status.thermostat_mode);
ResponseAppend_P(PSTR("%s\"%s\":%2_f"), ",", D_CMND_TEMPTARGETSET, &f_target_temp);
ResponseAppend_P(PSTR("%s\"%s\":%i"), ",", D_CMND_CTRDUTYCYCLEREAD, ThermostatGetDutyCycle(ctr_output));
ResponseAppend_P(PSTR("%s\"%s\":%i"), ",", D_CMND_CONTROLMETHOD, Thermostat[ctr_output].status.controller_mode == CTR_HYBRID ? Thermostat[ctr_output].status.phase_hybrid_ctr : Thermostat[ctr_output].status.controller_mode);
ResponseAppend_P(PSTR("%s\"%s\":%i"), ",", D_THERMOSTAT_JSON_NAME_CONTROL_METHOD, Thermostat[ctr_output].status.controller_mode == CTR_HYBRID ? Thermostat[ctr_output].status.phase_hybrid_ctr : Thermostat[ctr_output].status.controller_mode);
ResponseAppend_P(PSTR("%s\"%s\":%i"), ",", D_THERMOSTAT_JSON_NAME_EMERGENCY_STATE, Thermostat[ctr_output].diag.state_emergency == EMERGENCY_ON);
ResponseJsonEnd();
return;
}