Quick Fix: KNX loose config on restart (#21378)

* quick fix

* revert to ascillato test
This commit is contained in:
Barbudor 2024-05-10 10:46:40 +02:00 committed by GitHub
parent 3e8ca44681
commit 466dcae840
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194
1 changed files with 15 additions and 3 deletions

View File

@ -533,6 +533,21 @@ void KNX_INIT(void)
} }
} }
if (PinUsed(GPIO_DHT11) || PinUsed(GPIO_DHT22) || PinUsed(GPIO_SI7021)) {
device_param[KNX_TEMPERATURE-1].show = true;
device_param[KNX_HUMIDITY-1].show = true;
}
for (uint32_t i = 0; i < MAX_ADCS; i++) {
if (PinUsed(GPIO_ADC_TEMP, i)) {
device_param[KNX_TEMPERATURE-1].show = true;
}
}
#ifdef USE_DS18x20
if (PinUsed(GPIO_DSB, GPIO_ANY)) {
device_param[KNX_TEMPERATURE-1].show = true;
}
#endif
#if defined(USE_ENERGY_SENSOR) #if defined(USE_ENERGY_SENSOR)
// Any device with a Power Monitoring // Any device with a Power Monitoring
if ( TasmotaGlobal.energy_driver != ENERGY_NONE ) { if ( TasmotaGlobal.energy_driver != ENERGY_NONE ) {
@ -772,12 +787,9 @@ void KnxSensor(uint8_t sensor_type, float value)
if (sensor_type == KNX_TEMPERATURE) if (sensor_type == KNX_TEMPERATURE)
{ {
last_temp = value; last_temp = value;
device_param[KNX_TEMPERATURE-1].show = true;
} else if (sensor_type == KNX_HUMIDITY) } else if (sensor_type == KNX_HUMIDITY)
{ {
last_hum = value; last_hum = value;
device_param[KNX_HUMIDITY-1].show = true;
} }
if (!(Settings->flag.knx_enabled)) { return; } if (!(Settings->flag.knx_enabled)) { return; }