Generic Energy Modbus rename config JSON

This commit is contained in:
Theo Arends 2022-10-07 10:46:25 +02:00
parent ba8729f8d8
commit 625824caec
1 changed files with 42 additions and 46 deletions

View File

@ -23,21 +23,28 @@
* Generic Modbus energy meter - experimental (but works on my SDM230)
*
* Using a rule file called modbus allows to easy configure modbus energy monitor devices.
* See examples below
*
* Works:
* rule3 on file#modbus do {"name":"SDM230","baud":2400,"config":8N1","address":1,"function":4,"voltage":0,"current":6,"active_power":12,"apparent_power":18,"reactive_power":24,"power_factor":30,"frequency":70,"import_active_energy":342} endon
* rule3 on file#modbus do {"Name":"SDM230","Baud":2400,"Config":8N1","Address":1,"Function":4,"Voltage":0,"Current":6,"Power":12,"ApparentPower":18,"ReactivePower":24,"Factor":30,"Frequency":70,"ImportActive":342,"ExportActive":0x004A} endon
* rule3 on file#modbus do {"Name":"SDM230","Baud":2400,"Config":8N1","Address":1,"Function":4,"Voltage":0x0000,"Current":0x0006,"Power":0x000C,"ApparentPower":0x0012,"ReactivePower":0x0018,"Factor":0x001E,"Frequency":0x0046,"ImportActive":0x0156,"ExportActive":0x004A} endon
*
*
* Test set:
* rule3 on file#modbus do {"name":"SDM230 test1","baud":2400,"config":8N1","address":1,"function":4,"voltage":[0,0,0],"current":[6,6,6],"active_power":[12,12,12],"apparent_power":[18,18,18],"reactive_power":[24,24,24],"power_factor":[30,30,30],"frequency":[70,70,70],"import_active_energy":[342,342,342]} endon
* rule3 on file#modbus do {"name":"SDM230 test2","baud":2400,"config":8N1","address":1,"function":4,"voltage":[0,0,0],"current":[6,6,6],"active_power":[12,12,12],"apparent_power":[18,18,18],"reactive_power":[24,24,24],"power_factor":[30,30,30],"frequency":70,"import_active_energy":[342,342,342]} endon
* rule3 on file#modbus do {"Name":"SDM230 test1","Baud":2400,"Config":8N1","Address":1,"Function":4,"Voltage":[0,0,0],"Current":[6,6,6],"Power":[12,12,12],"ApparentPower":[18,18,18],"ReactivePower":[24,24,24],"Factor":[30,30,30],"Frequency":[70,70,70],"ImportActive":[342,342,342]} endon
* rule3 on file#modbus do {"Name":"SDM230 test2","Baud":2400,"Config":8N1","Address":1,"Function":4,"Voltage":[0,0,0],"Current":[6,6,6],"Power":[12,12,12],"ApparentPower":[18,18,18],"ReactivePower":[24,24,24],"Factor":[30,30,30],"Frequency":70,"ImportActive":[342,342,342]} endon
* rule3 on file#modbus do {"Name":"SDM230 test3","Baud":2400,"Config":8N1","Address":1,"Function":4,"Voltage":0,"Current":[6,6,6],"Power":[12,12,12],"ApparentPower":[18,18,18],"ReactivePower":[24,24,24],"Factor":[30,30,30],"Frequency":70,"ImportActive":[342,342,342]} endon
\*********************************************************************************************/
#define XNRG_29 29
#define ENERGY_MODBUS_SPEED 9600 // default Modbus baudrate
#define ENERGY_MODBUS_SPEED 9600 // default Modbus baudrate
#define ENERGY_MODBUS_CONFIG TS_SERIAL_8N1
#define ENERGY_MODBUS_ADDR 1 // default Modbus device_address
#define ENERGY_MODBUS_ADDR 1 // default Modbus device_address
#define ENERGY_MODBUS_FUNC 0x04 // default Modbus function code
//#define ENERGY_MODBUS_DEBUG
const uint16_t nrg_mbs_reg_not_used = 1; // Odd number 1 is unused register
enum EnergyModbusRegisters { NRG_MBS_VOLTAGE,
NRG_MBS_CURRENT,
@ -50,38 +57,26 @@ enum EnergyModbusRegisters { NRG_MBS_VOLTAGE,
NRG_MBS_EXPORT_ACTIVE_ENERGY,
NRG_MBS_MAX_REGS };
const char kEnergyModbusValues[] PROGMEM = "voltage|"
"current|"
"active_power|"
"apparent_power|"
"reactive_power|"
"power_factor|"
"frequency|"
"import_active_energy|"
"export_active_energy";
const char kEnergyModbusValues[] PROGMEM = D_JSON_VOLTAGE "|" // Voltage
D_JSON_CURRENT "|" // Current
D_JSON_POWERUSAGE "|" // Power
D_JSON_APPARENT_POWERUSAGE "|" // ApparentPower
D_JSON_REACTIVE_POWERUSAGE "|" // ReactivePower
D_JSON_POWERFACTOR "|" // Factor
D_JSON_FREQUENCY "|" // Frequency
D_JSON_IMPORT_ACTIVE "|" // ImportActive
D_JSON_EXPORT_ACTIVE "|" // ExportActive
;
#include <TasmotaModbus.h>
TasmotaModbus *EnergyModbus;
struct NRGMODBUS {
/*
uint16_t voltage[ENERGY_MAX_PHASES];
uint16_t current[ENERGY_MAX_PHASES];
uint16_t active_power[ENERGY_MAX_PHASES];
uint16_t apparent_power[ENERGY_MAX_PHASES];
uint16_t reactive_power[ENERGY_MAX_PHASES];
uint16_t power_factor[ENERGY_MAX_PHASES];
uint16_t frequency[ENERGY_MAX_PHASES];
uint16_t import_active[ENERGY_MAX_PHASES];
uint16_t export_active[ENERGY_MAX_PHASES];
*/
uint16_t register_address[NRG_MBS_MAX_REGS][ENERGY_MAX_PHASES];
uint32_t serial_bps;
uint32_t serial_config;
uint16_t register_address[NRG_MBS_MAX_REGS][ENERGY_MAX_PHASES];
uint8_t device_address;
uint8_t function;
uint8_t phase;
uint8_t state;
uint8_t retry;
@ -173,7 +168,7 @@ void EnergyModbusLoop(void) {
break;
}
}
} while (NrgModbus->register_address[NrgModbus->state][NrgModbus->phase] == 1);
} while (NrgModbus->register_address[NrgModbus->state][NrgModbus->phase] == nrg_mbs_reg_not_used);
}
} // end data ready
@ -188,53 +183,48 @@ void EnergyModbusLoop(void) {
bool EnergyModbusReadRegisters(void) {
#ifdef USE_RULES
String modbus = RuleLoadFile("MODBUS");
if (!modbus.length()) { return false; }
if (!modbus.length()) { return false; } // File not found
// AddLog(LOG_LEVEL_DEBUG, PSTR("NRG: File '%s'"), modbus.c_str());
// rule3 on file#modbus do {"name":"SDM230","baud":2400,"config":8N1","address":1,"function":4,"voltage":0,"current":6,"active_power":12,"apparent_power":18,"reactive_power":24,"power_factor":30,"frequency":70,"import_active_energy":342} endon
// rule3 on file#modbus do {"name":"SDM230 test1","baud":2400,"config":8N1","address":1,"function":4,"voltage":[0,0,0],"current":[6,6,6],"active_power":[12,12,12],"apparent_power":[18,18,18],"reactive_power":[24,24,24],"power_factor":[30,30,30],"frequency":[70,70,70],"import_active_energy":[342,342,342]} endon
// rule3 on file#modbus do {"name":"SDM230 test2","baud":2400,"config":8N1","address":1,"function":4,"voltage":[0,0,0],"current":[6,6,6],"active_power":[12,12,12],"apparent_power":[18,18,18],"reactive_power":[24,24,24],"power_factor":[30,30,30],"frequency":70,"import_active_energy":[342,342,342]} endon
// rule3 on file#modbus do {"name":"SDM230 test2","baud":2400,"config":8N1","address":1,"function":4,"voltage":0,"current":[6,6,6],"active_power":[12,12,12],"apparent_power":[18,18,18],"reactive_power":[24,24,24],"power_factor":[30,30,30],"frequency":70,"import_active_energy":[342,342,342]} endon
const char* json = modbus.c_str();
uint32_t len = strlen(json) +1;
if (len < 7) { return false; }
if (len < 7) { return false; } // Invalid JSON
char json_buffer[len];
memcpy(json_buffer, json, len); // Keep original safe
JsonParser parser(json_buffer);
JsonParserObject root = parser.getRootObject();
if (!root) { return false; }
if (!root) { return false; } // Invalid JSON
NrgModbus = (NRGMODBUS *)calloc(sizeof(struct NRGMODBUS), 1);
if (NrgModbus == nullptr) { return false; }
if (NrgModbus == nullptr) { return false; } // Unable to allocate variabvles on heap
// Init defaults
NrgModbus->serial_bps = ENERGY_MODBUS_SPEED;
NrgModbus->serial_config = ENERGY_MODBUS_CONFIG;
NrgModbus->device_address = ENERGY_MODBUS_ADDR;
NrgModbus->function = 0x04;
for (uint32_t i = 0; i < 9; i++) {
NrgModbus->function = ENERGY_MODBUS_FUNC;
for (uint32_t i = 0; i < NRG_MBS_MAX_REGS; i++) {
for (uint32_t j = 0; j < ENERGY_MAX_PHASES; j++) {
NrgModbus->register_address[i][j] = 1; // Not used
NrgModbus->register_address[i][j] = nrg_mbs_reg_not_used;
}
}
JsonParserToken val;
val = root[PSTR("baud")];
val = root[PSTR("Baud")];
if (val) {
NrgModbus->serial_bps = val.getInt(); // 2400
}
val = root[PSTR("config")];
val = root[PSTR("Config")];
if (val) {
const char *serial_config = val.getStr(); // 8N1
NrgModbus->serial_config = ConvertSerialConfig(ParseSerialConfig(serial_config));
}
val = root[PSTR("address")];
val = root[PSTR("Address")];
if (val) {
NrgModbus->device_address = val.getInt(); // 1
}
val = root[PSTR("function")];
val = root[PSTR("Function")];
if (val) {
NrgModbus->function = val.getInt(); // 4
}
@ -276,9 +266,15 @@ bool EnergyModbusReadRegisters(void) {
Energy.frequency_common = true; // Use common frequency
}
break;
case NRG_MBS_IMPORT_ACTIVE_ENERGY:
Settings->flag3.hardware_energy_total = 1; // SetOption72 - Enable hardware energy total counter as reference (#6561)
break;
}
}
}
#ifdef ENERGY_MODBUS_DEBUG
AddLog(LOG_LEVEL_DEBUG, PSTR("NRG: Registers %*_H"), sizeof(NrgModbus->register_address), NrgModbus->register_address);
#endif
// NrgModbus->state = 0; // Set by calloc()
// NrgModbus->phase = 0;