mirror of https://github.com/arendst/Tasmota.git
Add full support for BL0940
Add support for BL0940 energy monitor as used in Blitzwolf BW-SHP10 (#8175)
This commit is contained in:
parent
c6fede2bf4
commit
e54c85f83e
|
@ -75,3 +75,4 @@ The following binary downloads have been compiled with ESP8266/Arduino library c
|
|||
- Add ``FlashFrequency`` to ``status 4``
|
||||
- Add support for up to two BH1750 sensors controlled by commands ``BH1750Resolution`` and ``BH1750MTime`` (#8139)
|
||||
- Add support for up to eight MCP9808 temperature sensors by device111 (#8594)
|
||||
- Add support for BL0940 energy monitor as used in Blitzwolf BW-SHP10 (#8175)
|
||||
|
|
|
@ -17,6 +17,7 @@
|
|||
- Add ``FlashFrequency`` to ``status 4``
|
||||
- Add support for up to two BH1750 sensors controlled by commands ``BH1750Resolution`` and ``BH1750MTime`` (#8139)
|
||||
- Add Zigbee auto-responder for common attributes
|
||||
- Add support for BL0940 energy monitor as used in Blitzwolf BW-SHP10 (#8175)
|
||||
|
||||
### 8.3.1.1 20200518
|
||||
|
||||
|
|
|
@ -152,31 +152,9 @@ void Bl0940EverySecond(void) {
|
|||
Bl0940.current = 0;
|
||||
Bl0940.power = 0;
|
||||
} else {
|
||||
long cf_frequency = 0;
|
||||
|
||||
if (BL0940_PULSES_NOT_INITIALIZED == Bl0940.cf_pulses_last_time) {
|
||||
Bl0940.cf_pulses_last_time = Bl0940.cf_pulses; // Init after restart
|
||||
} else {
|
||||
if (Bl0940.cf_pulses < Bl0940.cf_pulses_last_time) { // Rolled over after 16777215 pulses
|
||||
cf_frequency = (0x1000000 - Bl0940.cf_pulses_last_time) + Bl0940.cf_pulses;
|
||||
} else {
|
||||
cf_frequency = Bl0940.cf_pulses - Bl0940.cf_pulses_last_time;
|
||||
}
|
||||
if (cf_frequency && Energy.active_power[0]) {
|
||||
unsigned long delta = (cf_frequency * Settings.energy_power_calibration) / 36;
|
||||
// prevent invalid load delta steps even checksum is valid (issue #5789):
|
||||
// if (delta <= (3680*100/36) * 10 ) { // max load for S31/Pow R2: 3.68kW
|
||||
// prevent invalid load delta steps even checksum is valid but allow up to 4kW (issue #7155):
|
||||
if (delta <= (4000*100/36) * 10 ) { // max load for S31/Pow R2: 4.00kW
|
||||
Bl0940.cf_pulses_last_time = Bl0940.cf_pulses;
|
||||
Energy.kWhtoday_delta += delta;
|
||||
}
|
||||
else {
|
||||
AddLog_P(LOG_LEVEL_DEBUG, PSTR("BL9: Load overflow"));
|
||||
Bl0940.cf_pulses_last_time = BL0940_PULSES_NOT_INITIALIZED;
|
||||
}
|
||||
EnergyUpdateToday();
|
||||
}
|
||||
if (Energy.active_power[0]) {
|
||||
Energy.kWhtoday_delta += (Energy.active_power[0] * 1000) / 36;
|
||||
EnergyUpdateToday();
|
||||
}
|
||||
}
|
||||
|
||||
|
|
Loading…
Reference in New Issue