Fixed Compressor and Operation for MiElHVAC

Changed Widevane position name from ISEE to AUTO sam as in MELCLoud
This commit is contained in:
Grzegorz 2024-10-13 15:17:40 +02:00
parent b934a8cb5d
commit f0973c84d4
1 changed files with 60 additions and 14 deletions

View File

@ -90,9 +90,16 @@ struct miel_hvac_data_roomtemp {
};
struct miel_hvac_data_status {
uint8_t _pad1[2];
uint8_t _pad1[3];
uint8_t compressor;
#define MIEL_HVAC_STATUS_COMPRESSOR_OFF 0x00
#define MIEL_HVAC_STATUS_COMPRESSOR_ON 0x01
uint8_t operation;
#define MIEL_HVAC_STATUS_OPERATION_OFF 0x00
#define MIEL_HVAC_STATUS_OPERATION_1 0x01
#define MIEL_HVAC_STATUS_OPERATION_2 0x02
#define MIEL_HVAC_STATUS_OPERATION_3 0x03
#define MIEL_HVAC_STATUS_OPERATION_4 0x04
};
struct miel_hvac_data {
@ -130,6 +137,9 @@ CTASSERT(offsetof(struct miel_hvac_data, data.settings.airdirection) == 14);
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.temp) == 3);
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.temp05) == 6);
CTASSERT(offsetof(struct miel_hvac_data, data.status.compressor) == 4);
CTASSERT(offsetof(struct miel_hvac_data, data.status.operation) == 5);
/* to hvac */
#define MIEL_HVAC_H_TYPE_CONNECT 0x5a
@ -206,7 +216,7 @@ struct miel_hvac_msg_update {
uint8_t _pad1[4];
uint8_t widevane;
#define MIEL_HVAC_UPDATE_WIDEVANE_MASK 0x0f
#define MIEL_HVAC_UPDATE_WIDEVANE_ISEE 0x00
#define MIEL_HVAC_UPDATE_WIDEVANE_AUTO 0x00
#define MIEL_HVAC_UPDATE_WIDEVANE_LL 0x01
#define MIEL_HVAC_UPDATE_WIDEVANE_L 0x02
#define MIEL_HVAC_UPDATE_WIDEVANE_C 0x03
@ -304,6 +314,11 @@ struct miel_hvac_map {
const char *name;
};
static const struct miel_hvac_map miel_hvac_power_map[] = {
{ MIEL_HVAC_UPDATE_POWER_OFF, "off" },
{ MIEL_HVAC_UPDATE_POWER_ON, "on" },
};
static const struct miel_hvac_map miel_hvac_mode_map[] = {
{ MIEL_HVAC_UPDATE_MODE_HEAT, "heat" },
{ MIEL_HVAC_UPDATE_MODE_DRY, "dry" },
@ -335,7 +350,7 @@ static const struct miel_hvac_map miel_hvac_vane_map[] = {
};
static const struct miel_hvac_map miel_hvac_widevane_map[] = {
{ MIEL_HVAC_UPDATE_WIDEVANE_ISEE, "isee" },
{ MIEL_HVAC_UPDATE_WIDEVANE_AUTO, "auto" },
{ MIEL_HVAC_UPDATE_WIDEVANE_LL, "left" },
{ MIEL_HVAC_UPDATE_WIDEVANE_L, "left_middle" },
{ MIEL_HVAC_UPDATE_WIDEVANE_C, "center" },
@ -362,6 +377,19 @@ static const struct miel_hvac_map miel_hvac_airdirection_map[] = {
{ MIEL_HVAC_UPDATE_AIRDIRECTION_DIRECT, "direct" },
};
static const struct miel_hvac_map miel_hvac_compressor_map[] = {
{ MIEL_HVAC_STATUS_COMPRESSOR_OFF, "off" },
{ MIEL_HVAC_STATUS_COMPRESSOR_ON, "on" },
};
static const struct miel_hvac_map miel_hvac_operation_map[] = {
{ MIEL_HVAC_STATUS_OPERATION_OFF, "off" },
{ MIEL_HVAC_STATUS_OPERATION_1, "1" },
{ MIEL_HVAC_STATUS_OPERATION_2, "2" },
{ MIEL_HVAC_STATUS_OPERATION_3, "3" },
{ MIEL_HVAC_STATUS_OPERATION_4, "4" },
};
enum miel_hvac_parser_state {
MIEL_HVAC_P_START,
MIEL_HVAC_P_TYPE,
@ -997,8 +1025,12 @@ miel_hvac_publish_settings(struct miel_hvac_softc *sc)
const char *name;
const char *name_swing_h;
Response_P(PSTR("{\"" D_JSON_IRHVAC_POWER "\":\"%s\""),
set->power ? "ON" : "OFF");
name = miel_hvac_map_byval(set->power,
miel_hvac_power_map, nitems(miel_hvac_power_map));
if (name != NULL) {
Response_P(PSTR("{\"" D_JSON_IRHVAC_POWER "\":\"%s\""),
name);
}
name = miel_hvac_map_byval( set->mode &
MIEL_HVAC_SETTINGS_MODE_MASK,
@ -1046,7 +1078,7 @@ miel_hvac_publish_settings(struct miel_hvac_softc *sc)
miel_hvac_airdirection_map, nitems(miel_hvac_airdirection_map));
if (name != NULL) {
ResponseAppend_P(PSTR(",\"AirDirection\":\"%s\""),
name_swing_h == "isee" ? name : "OFF");
name_swing_h == "auto" ? name : "OFF");
}
name = miel_hvac_map_byval(set->prohibit,
@ -1236,8 +1268,13 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
const char *name_swing_h;
ResponseAppend_P(PSTR("," "\"MiElHVAC\":{"));
ResponseAppend_P(PSTR("\"Power\":\"%s\""),
set->power ? "ON" : "OFF");
name = miel_hvac_map_byval(set->power,
miel_hvac_power_map, nitems(miel_hvac_power_map));
if (name != NULL) {
ResponseAppend_P(PSTR("\"Power\":\"%s\""),
name);
}
name = miel_hvac_map_byval( set->mode &
MIEL_HVAC_SETTINGS_MODE_MASK,
@ -1283,7 +1320,7 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
miel_hvac_airdirection_map, nitems(miel_hvac_airdirection_map));
if (name != NULL) {
ResponseAppend_P(PSTR(",\"AirDirection\":\"%s\""),
name_swing_h == "isee" ? name : "OFF");
name_swing_h == "auto" ? name : "off");
}
name = miel_hvac_map_byval(set->prohibit,
@ -1317,13 +1354,22 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
}
if (sc->sc_status.type != 0) {
const struct miel_hvac_data_status *s =
const struct miel_hvac_data_status *status =
&sc->sc_status.data.status;
ResponseAppend_P(PSTR(",\"Operation\":\"%s\""),
s->operation ? "ON" : "OFF");
ResponseAppend_P(PSTR(",\"Compressor\":\"%s\""),
s->compressor ? "ON" : "OFF");
name = miel_hvac_map_byval(status->compressor,
miel_hvac_compressor_map, nitems(miel_hvac_compressor_map));
if (name != NULL) {
ResponseAppend_P(PSTR(",\"Compressor\":\"%s\""),
name);
}
name = miel_hvac_map_byval(status->operation,
miel_hvac_operation_map, nitems(miel_hvac_operation_map));
if (name != NULL) {
ResponseAppend_P(PSTR(",\"Operation\":\"%s\""),
name);
}
}
if (sc->sc_temp.type != 0) {