mirror of https://github.com/arendst/Tasmota.git
parent
9747dd4b5c
commit
f3feb3ea6a
|
@ -26,68 +26,47 @@
|
|||
|
||||
const char *UnitfromType(const char *type) // find unit for measurment type
|
||||
{
|
||||
if (strcmp(type, "time") == 0)
|
||||
{
|
||||
return "_seconds";
|
||||
if (strcmp(type, "time") == 0) {
|
||||
return "seconds";
|
||||
}
|
||||
if (strcmp(type, "temperature") == 0 || strcmp(type, "dewpoint") == 0)
|
||||
{
|
||||
return "_celsius";
|
||||
if (strcmp(type, "temperature") == 0 || strcmp(type, "dewpoint") == 0) {
|
||||
return "celsius";
|
||||
}
|
||||
if (strcmp(type, "pressure") == 0)
|
||||
{
|
||||
return "_hpa";
|
||||
if (strcmp(type, "pressure") == 0) {
|
||||
return "hpa";
|
||||
}
|
||||
if (strcmp(type, "voltage") == 0)
|
||||
{
|
||||
return "_volts";
|
||||
if (strcmp(type, "voltage") == 0) {
|
||||
return "volts";
|
||||
}
|
||||
if (strcmp(type, "current") == 0)
|
||||
{
|
||||
return "_amperes";
|
||||
if (strcmp(type, "current") == 0) {
|
||||
return "amperes";
|
||||
}
|
||||
if (strcmp(type, "mass") == 0)
|
||||
{
|
||||
return "_grams";
|
||||
if (strcmp(type, "mass") == 0) {
|
||||
return "grams";
|
||||
}
|
||||
if (strcmp(type, "carbondioxide") == 0)
|
||||
{
|
||||
return "_ppm";
|
||||
if (strcmp(type, "carbondioxide") == 0) {
|
||||
return "ppm";
|
||||
}
|
||||
if (strcmp(type, "humidity") == 0)
|
||||
{
|
||||
return "_percentage";
|
||||
if (strcmp(type, "humidity") == 0) {
|
||||
return "percentage";
|
||||
}
|
||||
return "";
|
||||
}
|
||||
|
||||
const char *FormatMetricName(const char *metric) // cleanup spaces and uppercases for Prmetheus metrics conventions
|
||||
{
|
||||
char *formated = (char *)malloc(strlen(metric)+1);
|
||||
uint32_t cnt = 0;
|
||||
for (cnt; cnt < strlen(metric)+1; cnt++)
|
||||
{
|
||||
if (metric[cnt] == ' ')
|
||||
{
|
||||
formated[cnt] = '_';
|
||||
}
|
||||
else
|
||||
{
|
||||
formated[cnt] = tolower(metric[cnt]);
|
||||
}
|
||||
}
|
||||
return formated;
|
||||
String FormatMetricName(const char *metric) { // cleanup spaces and uppercases for Prmetheus metrics conventions
|
||||
String formatted = metric;
|
||||
formatted.toLowerCase();
|
||||
formatted.replace(" ", "_");
|
||||
return formatted;
|
||||
}
|
||||
|
||||
void HandleMetrics(void)
|
||||
{
|
||||
void HandleMetrics(void) {
|
||||
if (!HttpCheckPriviledgedAccess()) { return; }
|
||||
|
||||
AddLog_P(LOG_LEVEL_DEBUG, PSTR(D_LOG_HTTP "Prometheus"));
|
||||
|
||||
WSContentBegin(200, CT_PLAIN);
|
||||
|
||||
|
||||
char parameter[FLOATSZ];
|
||||
|
||||
// Pseudo-metric providing metadata about the running firmware version.
|
||||
|
@ -142,52 +121,43 @@ void HandleMetrics(void)
|
|||
String jsonStr = json;
|
||||
JsonParser parser((char *)jsonStr.c_str());
|
||||
JsonParserObject root = parser.getRootObject();
|
||||
if (root)
|
||||
{ // did JSON parsing went ok?
|
||||
for (auto key1 : root)
|
||||
{
|
||||
if (root) { // did JSON parsing went ok?
|
||||
for (auto key1 : root) {
|
||||
JsonParserToken value1 = key1.getValue();
|
||||
if (value1.isObject())
|
||||
{
|
||||
if (value1.isObject()) {
|
||||
JsonParserObject Object2 = value1.getObject();
|
||||
for (auto key2 : Object2)
|
||||
{
|
||||
for (auto key2 : Object2) {
|
||||
JsonParserToken value2 = key2.getValue();
|
||||
if (value2.isObject())
|
||||
{
|
||||
if (value2.isObject()) {
|
||||
JsonParserObject Object3 = value2.getObject();
|
||||
for (auto key3 : Object3)
|
||||
{
|
||||
for (auto key3 : Object3) {
|
||||
const char *value = key3.getValue().getStr(nullptr);
|
||||
if (value != nullptr && isdigit(value[0]))
|
||||
{
|
||||
const char *sensor = FormatMetricName(key2.getStr()); //cleanup sensor name
|
||||
const char *type = FormatMetricName(key3.getStr()); //cleanup sensor type
|
||||
const char *unit = UnitfromType(type); //grab base unit corresponding to type
|
||||
WSContentSend_P(PSTR("# TYPE tasmota_sensors_%s%s gauge\ntasmota_sensors_%s%s{sensor=\"%s\"} %s\n"), type, unit, type, unit, sensor, value); //build metric as "# TYPE tasmota_sensors_%type%_%unit% gauge\ntasmotasensors_%type%_%unit%{sensor=%sensor%"} %value%""
|
||||
if (value != nullptr && isdigit(value[0])) {
|
||||
String sensor = FormatMetricName(key2.getStr());
|
||||
String type = FormatMetricName(key3.getStr());
|
||||
const char *unit = UnitfromType(type.c_str()); //grab base unit corresponding to type
|
||||
WSContentSend_P(PSTR("# TYPE tasmota_sensors_%s_%s gauge\ntasmota_sensors_%s_%s{sensor=\"%s\"} %s\n"),
|
||||
type.c_str(), unit, type.c_str(), unit, sensor.c_str(), value); //build metric as "# TYPE tasmota_sensors_%type%_%unit% gauge\ntasmotasensors_%type%_%unit%{sensor=%sensor%"} %value%""
|
||||
}
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
} else {
|
||||
const char *value = value2.getStr(nullptr);
|
||||
if (value != nullptr && isdigit(value[0]))
|
||||
{
|
||||
const char *sensor = FormatMetricName(key1.getStr());
|
||||
const char *type = FormatMetricName(key2.getStr());
|
||||
const char *unit = UnitfromType(type);
|
||||
WSContentSend_P(PSTR("# TYPE tasmota_sensors_%s%s gauge\ntasmota_sensors_%s%s{sensor=\"%s\"} %s\n"), type, unit, type, unit, sensor, value);
|
||||
if (value != nullptr && isdigit(value[0])) {
|
||||
String sensor = FormatMetricName(key1.getStr());
|
||||
String type = FormatMetricName(key2.getStr());
|
||||
const char *unit = UnitfromType(type.c_str());
|
||||
if (strcmp(type.c_str(), "totalstarttime") != 0) { // this metric causes prometheus of fail
|
||||
WSContentSend_P(PSTR("# TYPE tasmota_sensors_%s_%s gauge\ntasmota_sensors_%s_%s{sensor=\"%s\"} %s\n"),
|
||||
type.c_str(), unit, type.c_str(), unit, sensor.c_str(), value);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
} else {
|
||||
const char *value = value1.getStr(nullptr);
|
||||
if (value != nullptr && isdigit(value[0] && strcmp(key1.getStr(), "Time") != 0)) //remove false 'time' metric
|
||||
{
|
||||
const char *sensor = FormatMetricName(key1.getStr());
|
||||
WSContentSend_P(PSTR("# TYPE tasmota_sensors_%s gauge\ntasmota_sensors{sensor=\"%s\"} %s\n"), sensor, sensor, value);
|
||||
String sensor = FormatMetricName(key1.getStr());
|
||||
if (value != nullptr && isdigit(value[0] && strcmp(sensor.c_str(), "time") != 0)) { //remove false 'time' metric
|
||||
WSContentSend_P(PSTR("# TYPE tasmota_sensors_%s gauge\ntasmota_sensors{sensor=\"%s\"} %s\n"), sensor.c_str(), sensor.c_str(), value);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
@ -200,8 +170,7 @@ void HandleMetrics(void)
|
|||
* Interface
|
||||
\*********************************************************************************************/
|
||||
|
||||
bool Xsns75(uint8_t function)
|
||||
{
|
||||
bool Xsns75(uint8_t function) {
|
||||
bool result = false;
|
||||
|
||||
switch (function) {
|
||||
|
|
Loading…
Reference in New Issue