Update changelogs

This commit is contained in:
Theo Arends 2024-10-28 14:12:44 +01:00
parent 27db263493
commit fc0dc5dfec
2 changed files with 3 additions and 1 deletions

View File

@ -18,6 +18,7 @@ All notable changes to this project will be documented in this file.
- Support for US AQI and EPA AQI in PMS5003x sensors (#22294) - Support for US AQI and EPA AQI in PMS5003x sensors (#22294)
- HLK-LD2410 Engineering mode (#21880) - HLK-LD2410 Engineering mode (#21880)
- Support for HLK-LD2410S 24GHz smart wave motion sensor (#22253) - Support for HLK-LD2410S 24GHz smart wave motion sensor (#22253)
- Mitsubishi Electric HVAC Auto Clear Remote Temp for MiElHVAC (#22370)
### Breaking Changed ### Breaking Changed

View File

@ -121,13 +121,14 @@ The latter links can be used for OTA upgrades too like ``OtaUrl https://ota.tasm
- DALI command `DaliGroup` to add gear to groups - DALI command `DaliGroup` to add gear to groups
- DALI command `DaliTarget` to set light control broadcast, group number or gear number - DALI command `DaliTarget` to set light control broadcast, group number or gear number
- DALI inverted signal configuration using GPIO DALI RX_i/TX_i - DALI inverted signal configuration using GPIO DALI RX_i/TX_i
- Support for Shelly DALI Dimmer Gen3 (See tips and template in file xdrv_75_dali.ino) - Support for Shelly DALI Dimmer Gen3
- Support for HLK-LD2410S 24GHz smart wave motion sensor [#22253](https://github.com/arendst/Tasmota/issues/22253) - Support for HLK-LD2410S 24GHz smart wave motion sensor [#22253](https://github.com/arendst/Tasmota/issues/22253)
- Support for US AQI and EPA AQI in PMS5003x sensors [#22294](https://github.com/arendst/Tasmota/issues/22294) - Support for US AQI and EPA AQI in PMS5003x sensors [#22294](https://github.com/arendst/Tasmota/issues/22294)
- HLK-LD2410 Engineering mode [#21880](https://github.com/arendst/Tasmota/issues/21880) - HLK-LD2410 Engineering mode [#21880](https://github.com/arendst/Tasmota/issues/21880)
- Mitsubishi Electric HVAC Operation time for MiElHVAC [#22334](https://github.com/arendst/Tasmota/issues/22334) - Mitsubishi Electric HVAC Operation time for MiElHVAC [#22334](https://github.com/arendst/Tasmota/issues/22334)
- Mitsubishi Electric HVAC Outdoor Temperature for MiElHVAC [#22345](https://github.com/arendst/Tasmota/issues/22345) - Mitsubishi Electric HVAC Outdoor Temperature for MiElHVAC [#22345](https://github.com/arendst/Tasmota/issues/22345)
- Mitsubishi Electric HVAC Compressor Frequency for MiElHVAC [#22347](https://github.com/arendst/Tasmota/issues/22347) - Mitsubishi Electric HVAC Compressor Frequency for MiElHVAC [#22347](https://github.com/arendst/Tasmota/issues/22347)
- Mitsubishi Electric HVAC Auto Clear Remote Temp for MiElHVAC [#22370](https://github.com/arendst/Tasmota/issues/22370)
- SolaxX1 Meter mode [#22330](https://github.com/arendst/Tasmota/issues/22330) - SolaxX1 Meter mode [#22330](https://github.com/arendst/Tasmota/issues/22330)
- BLE track devices with RPA [#22300](https://github.com/arendst/Tasmota/issues/22300) - BLE track devices with RPA [#22300](https://github.com/arendst/Tasmota/issues/22300)
- HASPmota `haspmota.get_pages()` to get the sorted list of pages [#22358](https://github.com/arendst/Tasmota/issues/22358) - HASPmota `haspmota.get_pages()` to get the sorted list of pages [#22358](https://github.com/arendst/Tasmota/issues/22358)