Commit Graph

9362 Commits

Author SHA1 Message Date
Theo Arends 4196f753c8 Update changelogs 2024-10-06 22:40:28 +02:00
Theo Arends 0240da2bf7 Fix Dali received data decoding
- Add support for DALI 1 on ESP8266
2024-10-06 21:57:59 +02:00
s-hadinger d9f246f0f0
LVGL port `colorwheel` from LVGL 8, HASPmota `cpicker` and `msgbox` (#22244) 2024-10-06 18:53:06 +02:00
Grzegorz ba687deaf5
Bridge Mitsubishi AC devices to Homebridge/Homekit locally (#22236)
* Update xdrv_44_miel_hvac.ino

Code structure cleanup,
Add Power, SetTemperature, Mode, SwingV, SwingH, FanSpeed to JSON StatusSNS MiElHVAC

* Update xdrv_44_miel_hvac.ino

* clesnup

* Revert "Update xdrv_44_miel_hvac.ino"

This reverts commit 45f813d32c.

* revert styling and format

* make operation and compressor indyvidual and remove unnecessary sep

* Update xdrv_44_miel_hvac.ino

* Update xdrv_44_miel_hvac.ino

* Use uppercase
2024-10-05 23:13:56 +02:00
Barbudor b09b3560b9
recreate 16044 (#22232) 2024-10-03 09:21:55 +02:00
Damian Wrobel bf0f7316b9
Avoid sending more then one Modbus TCP response (#22223)
Prevent from sending more then one Modbus TCP response
for a single request.

This might happen in the following scenario where,
shortly after the first response has been sent (4),
the second one will be send (8) (note the same
'TransactionId') triggered by the response to the
'ModbusSend' request issued by Berry (5).

The log excerpt from such a situation:

(1) 21:13:20.510 MBS: MBRTCP to Modbus TransactionId:520, deviceAddress:4, functionCode:3, startAddress:8193, count:1, recvCount:1, recvBytes:2
(2) 21:13:20.523 MBS: Serial Send: 04 03 20 01 00 01 DE 5F
(3) 21:13:20.647 MBS: Serial Received: 04 03 02 0A 28 72 FA
(4) 21:13:20.652 MBS: MBRTCP from Modbus TransactionId:520, deviceAddress:4, writing:11 bytes to client (error:0)
(5) 21:13:20.724 CMD: Grp 0, Cmd 'MODBUSSEND', Idx 1, Len 89, Pld -99, Data '{"deviceAddress":4, "functionCode":6, "startAddress":8192, "type":"uint16", "Values":[6]}'
(6) 21:13:20.743 MBS: Serial Send: 04 06 20 00 00 06 02 5D
(7) 21:13:21.009 MBS: Serial Received: 04 06 20 00 00 06 02 5D
(8) 21:13:21.014 MBS: MBRTCP from Modbus TransactionId:520, deviceAddress:4, writing:12 bytes to client (error:0)

Use 'tcp_transaction_id' field to denote that we already
sent a response.

Signed-off-by: Damian Wrobel <dwrobel@ertelnet.rybnik.pl>
2024-10-02 21:34:48 +02:00
Grzegorz 6fa38e4b83
Add heat/dry/cool isee operation mode to xdrv_44_miel_hvac.ino (#22216)
* Add heat/dry/cool isee operation mode to xdrv_44_miel_hvac.ino

This add heat, dry, and cool isle operation mode to support new AC devices. Closes also #10937

* remove duplicated wide vane mode
2024-09-30 11:21:12 +02:00
Theo Arends 2d80f87fc9 Attempt 2 to fix Dali core 3 compilation (#22214) 2024-09-30 09:50:15 +02:00
Theo Arends 5d4230d39b Attempt to fix Dali core 3 compilation (#22214) 2024-09-29 17:11:13 +02:00
Theo Arends 19d3984d6e Fix BL906 name (#22167) 2024-09-29 14:30:54 +02:00
Theo Arends b2b839fa83 Add support for Sonoff SPM v1.3.0 (#13447) 2024-09-28 17:57:31 +02:00
pharaocurt 5909eec188
fix compile error with core 3.0.0 for Range Extender driver xdrv_58_range_extender.ino (#22205)
* final ported range_extender

* removed #define USE_WIFI_RANGE_EXTENDER_PORTADD, because new framework-arduinoespressif32 @ 3.1.0+sha.22a3b096 is available with CONFIG_LWIP_IPV4_NAPT_PORTMAP=y
2024-09-27 20:16:28 +02:00
Theo Arends 452031fbbd Add Energy Export Active support to BL0906 (Athom EM2/EM6) 2024-09-27 18:08:22 +02:00
Theo Arends 692a0ca4b1 Bump version 14.2.0.6 2024-09-26 17:38:49 +02:00
Theo Arends d716a275bf Tune BL0906 driver 2024-09-26 17:20:34 +02:00
Theo Arends 08d75a5fe3 Add Support for BL0906 up to 6 channel energy monitor as used in Athom EM2/EM6 (#22167) 2024-09-25 18:11:07 +02:00
Theo Arends 27a4ea0f70 Add Support for BL0906 up to 6 channel energy monitor as used in Athom EM2/EM6 (#22167) 2024-09-25 18:05:16 +02:00
Theo Arends 61aeea9132 Add ESP8266 support for one-wire M1601 temperature sensor on DS18x20 GPIO (#21376) 2024-09-25 15:01:19 +02:00
Theo Arends 622b8b10c0 SSPM show only if powered ON 2024-09-25 11:06:51 +02:00
Theo Arends e3c47851b7 First fix SPM v1.3.0 report values (#13447) 2024-09-24 22:36:02 +02:00
Theo Arends 64de5497f4 Bump version v14.2.0.5
- Add ESP8266 support for I2C CLK on GPIO16 (#22199)
2024-09-24 17:44:15 +02:00
s-hadinger 330cfe8b4d
LVGL compilation of lv_menu (#22188) 2024-09-23 10:26:23 +02:00
gemu 3707d4b239
Sml update (#22185)
* some refactoring

* refactoring, save some ram
2024-09-22 12:20:02 +02:00
s-hadinger 7ef93b20fd
Add commented #define BE_LV_WIDGET_MENU 2024-09-22 11:52:00 +02:00
Jason2866 6bb046726e
arduino idf compile prepare 2024-09-21 23:36:37 +02:00
Theo Arends 03b57179ac Final fix unknown/error 2024-09-21 13:23:14 +02:00
Theo Arends 8d7a27df76 Fix ESP8266 Exception 3 on tasmota-minimal caused by unaligned PROGMEM (#22169) 2024-09-20 18:20:09 +02:00
Theo Arends bf4d0d0890 Revert "Fix ESP8266 Exception 3 on tasmota-minimal caused by unaligned PROGMEM (#22169)"
This reverts commit b00d7fd0ac.
2024-09-20 18:14:53 +02:00
Theo Arends b00d7fd0ac Fix ESP8266 Exception 3 on tasmota-minimal caused by unaligned PROGMEM (#22169) 2024-09-20 18:13:38 +02:00
Tim Connors 694691e34a
Refactor and fix PID sensor (PID_USE_LOCAL_SENSOR) read race condition (#22162)
* Refactor and fix PID sensor (PID_USE_LOCAL_SENSOR) read race condition

Refactor PID since it was calling pid.tick willy-nilly upon demand
from MQTT and the web instead of on a periodic basis (and was being
called with time interval of 0 when those times lined up!).  Refactor
web/mqtt display because there was shared code (that code turned out
to be misguided and belonged in Every_Second loop, but now we are also
similar to 39 thermostat)

Logging revealed that the vast majority of the time the sensor JSON
was parsed to obtain current sensor data when using PID local sensor,
it was failing to parse (and it would typically only work for a second
around TELE_PERIOD, but even then, not reliably).  This bug almost
certainly affects xdrv_39_thermostat too, but using
xsns_75_prometheus.ino as a template, we are able to update PV once
per second, which allows us to be a lot more responsive.  There is no
danger of being "too responsive" because that's the point of PID, and
the PID loop already scales feedback by interval between ticks.

* Reduce logging of PID now that query side-effects removed

* Comment out all new logging, but leave present for next debugger
2024-09-20 12:06:41 +02:00
Theo Arends 83eb8aeaa7 Update changelogs 2024-09-20 12:01:15 +02:00
s-hadinger be46b95d62
MQTT add warning if trying to connect without TLS on a port that normally uses TLS (#22175) 2024-09-19 23:12:46 +02:00
Theo Arends 3b28542d9c Fix BMP second bus 2024-09-19 17:21:08 +02:00
Theo Arends 9238ee73d6 Add ESP8266 experimental support for second I2C bus 2024-09-19 14:47:18 +02:00
Theo Arends a9f0623769 SCD30 Lowered I2C clock from 100k to 50k (#15438) 2024-09-19 11:15:04 +02:00
Theo Arends d0d075a1b4 Refactored I2C drivers SHT3x and iAQ 2024-09-19 11:11:08 +02:00
Theo Arends a30f47a901 Fix bad define ESP82666 2024-09-19 11:07:16 +02:00
Theo Arends a5730a76f9 Add command entered to command error and command unknown message 2024-09-17 16:24:45 +02:00
Theo Arends 4f2b24f53d Add entered command to MQTT command unknown message (bis) 2024-09-17 10:19:00 +02:00
Theo Arends fd7d2fc0a4 Add entered command to MQTT command unknown message 2024-09-17 10:00:47 +02:00
Theo Arends 97970974fc Refactored I2C drivers HTU21, BH1750 and HYT 2024-09-16 16:27:30 +02:00
Theo Arends c61dd0fd2c Minor refactor I2C 2024-09-15 15:16:18 +02:00
Theo Arends a3892ecbc4 Update change logs 2024-09-14 16:13:14 +02:00
s-hadinger 1bfbe02a29
Berry I2C to prepare M5Stack I2C STM32 based devices (#22143) 2024-09-14 12:25:23 +02:00
Theo Arends 1dff0b4b27 Add support for RX8010 RTC as used in IOTTIMER (#21376) 2024-09-13 13:53:01 +02:00
s-hadinger 6e4517de02
Berry virtual Energy driver (#22134) 2024-09-12 19:38:04 +02:00
Theo Arends 7b8308c36a Add support for I2C M5Unit (Mini)Scales using HX711 driver 2024-09-12 12:14:32 +02:00
s-hadinger 9d012f64c8
Add internal I2C argument to send stop while reading (#22127) 2024-09-11 16:41:35 +02:00
Pavel Sheremetev 1edc4b57b7
allow define calibration parametrs for bl09xx (#22030)
Co-authored-by: PavelSheremetev <spd@aira.life>
2024-09-11 08:55:43 +02:00
Theo Arends d8f01ed4c0 Refactor HX711 memory use 2024-09-10 15:59:25 +02:00
stefanbode 05e59b048e
Fix remaining issues on shutterinvert (#22120)
found another place where the invert was not reported correctly
2024-09-10 14:48:51 +02:00
gemu 1c730aab86
fix trx pin error (#22119) 2024-09-10 14:48:38 +02:00
s-hadinger 2d522485c4
Zigbee fix flashing CC2562P with latest firmware (#22117) 2024-09-09 21:56:18 +02:00
s-hadinger 7247cd6c44
Fixed Berry energy missing attributes (#22116) 2024-09-09 21:50:06 +02:00
Damian Wrobel 6650dee578
Fix ModbusBridge request/response logic (#22075)
- Fix cases where the subsequent Modbus packet
  can be send to the serial port (triggered either by
  'ModbusSend' command or request from TCP bridge)
  before an answer was received to the previous packet.

  This can happen in a setup where simultaneously:
  - two (or more) modbus TCP clients are sending requests
    through the modbus-proxy [1] to Tasmota,
  - ModbusSend commands are executed (e.g. using Berry).

  Log excerpt (from build with TASMOTAMODBUSDEBUG enabled):
  14:51:18.940 MBS: Serial Send: 04 03 01 00 00 09 84 65
  14:51:19.054 MBS: Serial Send: 04 03 10 0A 00 05 A1 5E
  14:51:19.136 MBS: Serial Received: 04 03 0A 00 00 00 D0 00 00 01 AB 00 00 89 62

  Fix adds 'waitingForAnswerFromSerial' flag which is set after
  we send data to the serial port and prevents sending another
  requests before we receive an answer or timeout happened.

  Fix stores temporarily a 'ModbusSend' command data and tries
  to execute it after Modbus response has been received or
  timeout has happened.

- Add 'ModbusSerialTimeout' command which sets timeout in [ms]
  for how long we will be waiting for an answer from the client device.
  Default value is 1000 [ms] and it is not restored after reboot.

- Sends error 11 (0xB) (as TCP response) when no answer was received
  from the serial port within the timeout set by 'ModbusSerialTimeout'
  command.

- Add Modbus 'TransactionId' to the logging.

[1] https://github.com/tiagocoutinho/modbus-proxy

Signed-off-by: Damian Wrobel <dwrobel@ertelnet.rybnik.pl>
2024-09-09 10:26:20 +02:00
pbrinette 28bbf11dbb
Enhance the KNX capabilities of Tasmota to offer more flexibility and features (#22071) 2024-09-09 09:25:11 +02:00
s-hadinger 9ac2a69603
Matter support for Zigbee Occupancy and Light 0/1/2 (OnOff / Dimmer / White Color Temperature) (#22110) 2024-09-08 23:16:19 +02:00
Theo Arends 1bf6a13d7c Bump version v14.2.0.4
- Add HX711 optional calibration precision option on command ``Sensor34 2 <weight in gram> <precision>`` where `<precision>` is 1 to 10 (#13983)
2024-09-08 17:32:35 +02:00
stefanbode 744e50acf7
Fix missing HOLD on shutterbutton (#22108)
#21986
2024-09-08 16:50:37 +02:00
gemu 2c5e8749e3
multi trx lines (#22056) 2024-09-07 15:29:27 +02:00
Jason2866 069f59d13f
remove irritating space (#22095) 2024-09-05 16:51:45 +02:00
s-hadinger 5f80251414
Berry Zigbee improvements to prepare Matter (#22083) 2024-09-03 23:22:50 +02:00
s-hadinger 4164887412
Zigbee avoid disabling console serial on ESP32 and improved log messages (#22082) 2024-09-03 23:06:07 +02:00
s-hadinger b6e81c1edd
Zigbee Koenkk firmware 20240710 for Sonoff Zigbee ZBPro (#22076) 2024-09-02 22:20:41 +02:00
Steffen caa501b1af
add support for nexus protocol to rc-switch library (#21886)
* add support for nexus protocol to RCSwitch library

Nexus protocol is used by temperature and humidity sensor that operate at 433 MHz.
It is used by various brands.

* calc separation limit for RCSwitch library automatically
2024-09-01 16:04:40 +02:00
s-hadinger 11ed65560b
LVGL Added OpenHASP icons to font `montserrat-28` (#22048) 2024-08-29 16:57:01 +02:00
s-hadinger e7f120d443
Berry make `energy` modules changes from #21887 backwards compatible (#22046) 2024-08-29 16:02:14 +02:00
s-hadinger e8cdeaba6b
ESP32 LVGL library from v9.1.0 to v9.2.0 (#22031) 2024-08-27 23:36:38 +02:00
Theo Arends a10e3b9bc5 GPIOViewer function shuffle. No functional changes 2024-08-26 16:48:39 +02:00
Theo Arends 969611835c Fix GPIOViewer on ESP32 (needs upcoming core change) 2024-08-26 15:26:36 +02:00
Theo Arends f0c12b6e9c Remove dash from GUI title 2024-08-26 14:20:51 +02:00
Theo Arends fefd49c663 Remove dash from GUI title 2024-08-26 14:14:59 +02:00
pkkrusty 88c9ae3273
Clarify MAX7219 display driver (#21977)
MAX7219 and MAX7219_MATRIX are different displays and require different defines. DisplayModel19 incorrectly listed for MAX7219 instead of MAX7219_MATRIX.
2024-08-26 08:49:48 +02:00
gemu c35c493809
i2s wav player (#22003)
* i2s wav player

* move framepointer
2024-08-26 08:48:35 +02:00
s-hadinger 645ce4a1ee
Zigbee reduce serial logging (#22012) 2024-08-24 23:53:42 +02:00
s-hadinger d084be23db
Zigbee extend timeout for MCU reboot from 5s to 10s (#22009) 2024-08-24 18:32:35 +02:00
Theo Arends 831597e7d9 Version v14.2.0.3
- Add command ``SetOption69 1`` to enable Serial Bridge inverted Receive (#22000)
2024-08-23 11:22:26 +02:00
Theo Arends 4144f5c5ca Change GPIOViewer from v1.5.5 to v1.5.6 2024-08-22 18:03:39 +02:00
Theo Arends 798edc20c2 Version v14.2.0.2
- Changed Energy BL09xx command ``CurrentSet`` input changed from Ampere to milliAmpere
2024-08-21 16:27:43 +02:00
Theo Arends ba7161fb00 Fix ESP8266 energy cal range chk 2024-08-20 17:30:18 +02:00
Theo Arends ab2d6c1169 Add Energy command ``PowerSet 60,230`` to calibrate both Current and Power with known resistive load of 60W at 230V using calibrated Voltage 2024-08-20 13:08:56 +02:00
Theo Arends c5b92d3ab1 Add Energy Log level 4 message when (Calculated) Apparent Power is less than Active Power indicating wrong calibration (#20653) 2024-08-19 22:31:56 +02:00
Theo Arends 4f62a0deab Refactor to TimeReacged() 2024-08-18 12:46:23 +02:00
Theo Arends e74142724c Disable 64-bit timing support 2024-08-18 12:13:44 +02:00
Theo Arends 903686f7b5 Add 64-bit timing support 2024-08-16 11:56:07 +02:00
Theo Arends c0eb28dae9 Harden shutter timeouts 2024-08-16 11:53:58 +02:00
Theo Arends 652b9cef87 Fix PZEM continue energy monitoring when one phase fails (#21968) 2024-08-15 17:32:11 +02:00
stefanbode 6d2647fd5f
fix potential overflow on uptime 2nd try (#21966)
* fix potential overflow

* fix potential overflow

* fix overflow on millis()

* fix overflow on millis()

* Update xdrv_27_shutter.ino

---------

Co-authored-by: Theo Arends <11044339+arendst@users.noreply.github.com>
2024-08-15 14:28:10 +02:00
Theo Arends 1b24378da5 Free 500 code bytes on ADC/ESP8266 2024-08-15 12:52:12 +02:00
stefanbode 851f11dcdd
fix potential overflow on uptime (#21965)
* fix potential overflow

* fix potential overflow

* fix potential overflow

* fix potential overflow
2024-08-15 10:08:54 +02:00
Theo Arends 30cffa1acc Bump version v14.2.0.1 2024-08-14 15:13:00 +02:00
Theo Arends 102428f768 Needed too 2024-08-13 15:13:04 +02:00
Theo Arends b93e6cee7b Change GUI name of Analog<x> to ADC<x> 2024-08-13 15:11:51 +02:00
Theo Arends ff46745252 Fix ADC conversion to v14.1.0.4 2024-08-13 13:57:58 +02:00
Theo Arends 8f75684cd7 Add Rule and Scripter xdrv sensor polling 2024-08-13 12:28:09 +02:00
Theo Arends 5bac2a2331 Revert "Add Rule and Scripter xdrv sensor polling"
This reverts commit cc2ea328d5.
2024-08-11 19:29:10 +02:00
Theo Arends cc2ea328d5 Add Rule and Scripter xdrv sensor polling 2024-08-11 17:47:01 +02:00
Theo Arends d3f6d7d844 Sync ESP8266 energydriver with ESP32 2024-08-10 17:15:05 +02:00
Theo Arends 85da678132 Fix ADC bad energy jumps 2024-08-10 17:01:14 +02:00
Theo Arends bcd1a9c986 Fix ADC multiple GPIO parameter storage 2024-08-09 16:11:30 +02:00