* Update xsns_18_pms5003.ino
The Winsum ZH03B sensor is quite similar to the Plantower PMS3003 sensor. The main difference is the response in passive mode. With these changes xsns_18_pms5003.ino can support the ZH03B sensor when PMS_MODEL_ZH03X is defined in the configuration file.
* Update xsns_18_pms5003.ino
ESP32 ADC has variables errors, but calibrations values are put in eFuses at factory test.
analogReadMilliVolts() from api correct the ADC reading with tata values.
Since now the value are mV and not ADC numbers, the fast solution is to revert it back to ADC numbers:
divide by Vcc => ANALOG_V33*1000 and multiply by ANALOG_RANGE
Other way is to modify all sensor cases to account for the different unit.
* Add new setting windmeter_measure_intvl and update speed computation
* Ensure windmeter_measure_intvl is not below 1
* Keep same settings order in response messages and add better comments
* Add files via upload
Added ENS16x library enabling read-out of ENS160 and ENS161 sensor component (follow-up of CCS811 and iAQcore)
Added ENS210 library to read out ENS210 temperature & humidity sensor
* Add files via upload
Add air quality sensor readout for ENS160 and ENS161 checking two possible I2C addresses (follow up sensor for CCS811 and iAQcore)
Add temperature and humidity sensor readout checking two possible I2C addresses
* Update BUILDS.md
Add USE_ENS16x and USE_ENS210
* Update decode-status.py
Add USE_ENS16x and ENS210
* Update I2CDEVICES.md
Add USE_ENS16x and USE_ENS210
* Update my_user_config.h
Add USE_ENS16x and USE_ENS210
* Update support_features.ino
Add USE_ENS16x and USE_ENS210
* Update tasmota_configurations.h
Add USE_ENS16x and ENS210
* Update tasmota_configurations_ESP32.h
Add USE_ENS16x and USE_ENS210
* Update xsns_111_ens16x.ino
Corrected I2X number
* Update xsns_112_ens210.ino
Corrected I2C number
* Disable USE_ENS16x and USE_ENS210 by default
* Added code size information
* cut down in libs
* optimize tasmota side
* fix ens16x web display
* final fix on alternate addresses
* update code & RAM usage
---------
Co-authored-by: Barbudor <barbudor@barbudor.net>
* fix: don't reset the device when coming out of deep sleep
* fix: move debug log message to inside the device validation
* Update xsns_110_max17043.ino
* add: update global battery percentage when max17043 reports new value
* Added a passive mode in sen5x sensor for parasitic installations. This skips reset & initialization of sensor on startup and reduces the polling to every 10 seconds to not interfere with and confuse the other I2C master on the bus, e.g. Ike* Vindstyrka.
* Removed obsolete updateCount. Cleanup.
* [DS18x20] Enhance use of aliases
`defineDS18x20_USE_ID_AS_NAME`:
Always show part of the address, even for one sensor
`#define DS18x20_USE_ID_ALIAS`:
The command `DS18Alias` can now be use with alphanumeric aliases, which replace the sensor name
* [DS18x20] change to calloc()