* Add new setting windmeter_measure_intvl and update speed computation
* Ensure windmeter_measure_intvl is not below 1
* Keep same settings order in response messages and add better comments
* Add files via upload
Added ENS16x library enabling read-out of ENS160 and ENS161 sensor component (follow-up of CCS811 and iAQcore)
Added ENS210 library to read out ENS210 temperature & humidity sensor
* Add files via upload
Add air quality sensor readout for ENS160 and ENS161 checking two possible I2C addresses (follow up sensor for CCS811 and iAQcore)
Add temperature and humidity sensor readout checking two possible I2C addresses
* Update BUILDS.md
Add USE_ENS16x and USE_ENS210
* Update decode-status.py
Add USE_ENS16x and ENS210
* Update I2CDEVICES.md
Add USE_ENS16x and USE_ENS210
* Update my_user_config.h
Add USE_ENS16x and USE_ENS210
* Update support_features.ino
Add USE_ENS16x and USE_ENS210
* Update tasmota_configurations.h
Add USE_ENS16x and ENS210
* Update tasmota_configurations_ESP32.h
Add USE_ENS16x and USE_ENS210
* Update xsns_111_ens16x.ino
Corrected I2X number
* Update xsns_112_ens210.ino
Corrected I2C number
* Disable USE_ENS16x and USE_ENS210 by default
* Added code size information
* cut down in libs
* optimize tasmota side
* fix ens16x web display
* final fix on alternate addresses
* update code & RAM usage
---------
Co-authored-by: Barbudor <barbudor@barbudor.net>
* Improvement in shuttersetup
- reduce call of energy to 10x a sec.
- stop detection more rigid to avoid wrong messages
- more accurate calculation of duration
* fix energy hickup on autosetup
* fix: don't reset the device when coming out of deep sleep
* fix: move debug log message to inside the device validation
* Update xsns_110_max17043.ino
* add: update global battery percentage when max17043 reports new value
* `Sendmail` upgraded to ESP-Mail-Client v3.4.9 from v1.2.0, using BearSSL instead of MbedTLS
* Fix compilation on ESP8266
* Fix compilation
* fix compilation
* Added a passive mode in sen5x sensor for parasitic installations. This skips reset & initialization of sensor on startup and reduces the polling to every 10 seconds to not interfere with and confuse the other I2C master on the bus, e.g. Ike* Vindstyrka.
* Removed obsolete updateCount. Cleanup.
* Add new webcam driver over latest dev. To use the old one, define USE_WEBCAM_LAGACY
* enable build without RTSP.
check pin_pwdn before using it n 0x105!!!
* more fixes around pwdn. Make wcresolution -1 set the resoltuion setting to 'disbale cam' value (15).
* fix task stop - wait for debug to leave-> prevents guru. pin task to core 0.
* split motion from other code. Add USE_WEBCAM_MOTION to control inclusion of motion code (big hit). Change from using USE_WEBCAM_LEGACY to USE_WEBCAM_V2
* logging minimisation - behind WEBCAM_DEV_DEBUG
* [DS18x20] Enhance use of aliases
`defineDS18x20_USE_ID_AS_NAME`:
Always show part of the address, even for one sensor
`#define DS18x20_USE_ID_ALIAS`:
The command `DS18Alias` can now be use with alphanumeric aliases, which replace the sensor name
* [DS18x20] change to calloc()
* add: update DEBUG_THERMOSTAT to only control the virtual switch
Also, debug output is still generated but end user can control this debug level 3
* add: debug output of main controller parameters when thermostat enabled
Also, add units for debug outputs added to make them more intelligible
* Update xdrv_39_thermostat.ino
* add: debug message when sensor is detected as not alive
fix: display thermostat number in debug messages
* add: log message prefix string for thermostat
* Update xdrv_39_thermostat.ino
fix: typos in comments
add: debug messages
* add: debug prefix for thermostat
* add: debug prefix added to output lines
* fix: comment typos and small grammatical changes for clarity
* add: debug prefix 'THE' added to debug output
* add: display PID status and key info on web output
* fix: remove extraneous comments that included unused code fragments
* add: local sensor handling improvements
add: define a local sensor name
add: define the local sensor measurement parameter
add: limit sensor not seen error message to every 60 seconds to avoid flooding the logs
add: include interval since which sensor data was last updated
fix: properly update the maximum interval time so missing sensor data is properly alerted
* Update xdrv_49_pid.ino
* add: update DEBUG_THERMOSTAT to only control the virtual switch
Also, debug output is still generated but end user can control this debug level 3
* add: debug output of main controller parameters when thermostat enabled
Also, add units for debug outputs added to make them more intelligible
* Update xdrv_39_thermostat.ino
* add: debug message when sensor is detected as not alive
fix: display thermostat number in debug messages
* add: log message prefix string for thermostat
* Update xdrv_39_thermostat.ino
fix: typos in comments
add: debug messages
* add: debug prefix for thermostat
* add: debug prefix added to output lines
* fix: comment typos and small grammatical changes for clarity
* add: debug prefix 'THE' added to debug output
* skip stop on hold if grouptopic
If shutterbutton is defined with a grouptopic send on HOLD, there is no stop on releasing the button. All shutters will move to defined position
* do not stop on hold release if group submitt
If mqtt broadcast is defined on hold then release the hold button will not anymore stop the local shutter. All shutter will move to defined position