Commit Graph

15 Commits

Author SHA1 Message Date
arendst c16fd3d99e v5.7.1d
5.7.1d
 * Fix watchdog timeout caused by lack of stack space by now
using global buffers (#853)
 * Removed webserver syslog disable as now
no longer needed
 * Increased default MQTT message size from 368 to 405
bytes while keeping DMQTT_MAX_PACKET_SIZE = 512 (because we can)
 * Fix
MQTT Offline or Remove MQTT retained topic code
 * Allow command
SwitchTopic in group mode (#861)
 * Allow command SwitchMode if no
switches are defined (#861)
2017-09-13 14:19:34 +02:00
arendst 0fbbc23b2c Add I18n and fix invalid JSON
5.6.1i
* Add basic internationalization and localization (#763)
* Fix invalid JSON (#822)
2017-09-02 14:37:02 +02:00
arendst 70ccdfe9b9 v5.1.3
5.1.3 20170520
* Add Domoticz Counter
2017-05-20 14:03:34 +02:00
arendst f6f6616c9d v5.1.0
5.1.0 20170513
* Fix Offline/Removal of retained topic when FullTopic is changed
* Add FullTopic to MQTT Configuration and Information web page
* Adde license model GPLv3 (#188)
2017-05-13 13:02:10 +02:00
arendst c61a39a06d v5.0.2
5.0.2 20170503
* Reset SaveData, SaveState and MqttResponse to default values due to
rearranging settings
* Moved some settings flag area
* Add command TempUnit Celsius|Fahrenheit for selecting Celsius or
Fahrenheit (#347)
* Add command TempRes 0..3 for selecting Temperature Resolution (#347)
* Add command HumRes 0..3 for selecting Humidity Resolution (#347)
* Add command PressRes 0..3 for selecting Pressure Resolution (#347)
* Add command EnergyRes 0..5 for selecting Energy Resolution (#347)
* Add "TemperatureUnit":"C|F" to sensor JSON output (#347)
* Add support for up to three DHT type sensors each using a different
GPIO (#339, #404)
2017-05-03 18:19:13 +02:00
arendst ecc6bb5fdc v5.0.0
5.0.0 20170425
* Memory status message update
* Fix setting migration to better preserve settings during move (#382)
* Best practice is first doing a Backup Configuration before installing
version 5.0.0
* Reset save count after setting move
* Start using new linker script without SPIFFS
2017-04-25 18:24:42 +02:00
arendst 824368125b v4.1.3
4.1.3 20170410
* Add user configuarble GPIO to module S20 Socket and Slampher
* Add support for Sonoff SC (#112)
* Set PWM frequency from 1000Hz to 910Hz as used on iTead Sonoff Led
firmware (#122)
* Set Sonoff Led unconfigured floating outputs to 0 to reduce exceptions
due to power supply instabilities (#122)
* Add Access Point Mac Address to Status 11 and Telemetry (#329)
* Fix DS18B20 negative temperature readings (#334)
2017-04-10 17:25:31 +02:00
arendst a8f2293a66 v4.1.1
4.1.1 20170329
* Fix default Telemetry for command Prefix3
* Fix webserver Module parameters for disabled select
* Fix sensor status for enabled switches
* Remove Light as alternative for Power (save code space)
* Remove migration option from pre V3 (code cleanup)
* Remove unofficial SPIFFS support (code cleanup)
* Remove command list when unknown command is entered (save code space)
* Rename Status11 json from StatusPWR to unique StatusSTS
* Rename command Gateway to IPAddres2, Subnetmask to IPAddress3 and
DnsServer to IPAddress4 (save code space)
* Add Command MqttResponse to select either command or RESULT topic as
response (#258)
* Add command StateText1 to StateText3 to assign MQTT_STATUS_OFF,
MQTT_STATUS_ON and MQTT_CMND_TOGGLE respectively (#286)
* Remove restart after IPAddress changes (#292)
* Add support for MAX31850 in xsns_ds18x20.ino (#295)
* Fix possible uptime update misses (#302)
2017-03-29 18:42:05 +02:00
arendst ac84010015 v4.0.2
4.0.2 20170308
* Restore correct seriallog level after Serial logging was disabled
* Add simple dimmer slider to Sonoff Led web page
* Reduced root webpage size by 31%
* Expand Status 2 with Build date/time and core version
* Fix webserver redirection when not in WifiManager mode (#156)
* Add command ButtonRestrict On/Off to restrict access to button hold
and button multi press options above 2 (#161)
* Fix DS18S20 negative temperature readings (#165)
* Fix crlf compilation error due to bad syntax (#144, #167)
2017-03-08 16:20:45 +01:00
arendst 47d711b1b2 v4.0.1
4.0.1 20170305
* Fix char default sizes and set MESSZ to 360 (#143)
* Fix SerialLog setting status
* Disable syslog when emulation is active
* Add DS18B20 web page display refresh
2017-03-05 15:07:30 +01:00
arendst fc3b7e22ab v3.9.22
3.9.22 20170228
* Update web console
* Fix Status 4 JSON message
* Add Exception info during restart if available
* Add osWatch service to detect loop hangs that might happen during
(OTA) upgrades
* Add WiOn support for relay and switch only (#82, #102)
* Allow for user specified relay count up to four in sonoff_template.h
(#109)
* Add support for HTU21 compatible I2C sensors SI7013, SI7020 and SI7021
(#118)
* Add NodeMCU or Wemos configuration option (#119)
2017-02-28 16:01:48 +01:00
arendst 533855c210 v3.9.15
3.9.15 20170213
* Change JSON float values from string to number according to
http://json.org (#56)
* Add support for exs latched relay module
https://ex-store.de/ESP8266-WiFi-Relay-V31 (#58)
* Add support for inverted relays
* Changed MAX_LOG_LINES from 70 to 60 to preserve memory
2017-02-13 17:25:46 +01:00
arendst bb5251c2c8 v3.9.14
3.9.14 20170211
* Add False and True as alternatives for 0/Off and 1/On (#49)
* Fix Status10 JSON format (#52)
* Fix DS18x20 using OneWire library (#53)
2017-02-11 15:06:23 +01:00
arendst 213e8d8095 v3.9.11
3.9.11 20170204
* Fix command I2Cscan
* Fix not allowed spaces in Topic, ButtonTopic and SwitchTopic
* Make all TELEMETRY, STATUS and COMMAND message topics unique (#4)
* Advertise command topic to be used by iobroker (#299)
* Fix butten (non)detection if no GPIO_KEY1 is defined (#13)
* Change WeMo serialnumber from 7 decimal chars to 8 hexadecimal chars
(#18)
* Update web page with Build Date/Time, Emulation and mDNS Discovery and
Advertise information (#21)
2017-02-04 17:09:54 +01:00
arendst d392cf2f77 v3.9.4 2017-01-28 14:41:01 +01:00