More and more Tuya MCU based devices are coming in the market and people requesting to support them. This patch makes Tuya module more configurable and easier to add new functionalities. Its not just a dimmer or a switch anymore.
After this Patch Tuya MCU module has a list of supported functions and the user would need to map the functionId to dpId of their device. Once mapped correctly the Tuya module will take care for handling proper function for dpId.
Currently functions supported are
1. Relays1 to 8 : FunctionID 11 to 18
2. Dimmer : FunctionID 21
3. Power ( Deca Watt ) : Function ID 31
4. Current ( milli Amps ) : Function ID 32
5. Voltage ( deca Volts ) : Function ID 33
The changes are
- Use a TuyaMCU command to map DPs to Functions instead of many different SetOptions. SetOption41, 44, 45, 46, 65 won't be needed after this patch.
- TuyaMCU command takes argument like `11,1` which means Map Function id 11 (Relay1) to DPID 1
- Migrates old settings flags and options to new TuyaMap command
* Add Tuya Energy monitoring by Shantur Rathore
* Add phase 1 Domoticz P1 Smart Meter support using energy sensors handled by xdrv_03_energy.ino based on an idea by pablozg
* Add commands Tariff1 0..23 (start Off-Peak hour), Tariff2 0..23 (start Standard hour) and Tariff3 0/1 (Saturday and Sunday Off-Peak)
6.5.0.16 20190611
* Refactored TLS based on BearSSL, warning breaking change for fingerprints validation (see doc)
* Add checkbox to GUI password field enabling visibility during password entry only (#5934)
6.5.0.14 20190602
* Change webserver HTML input, button, textarea, and select name based on id
* Fix webserver multiple Javascript window.onload functionality
6.5.0.12 20190521
* Add AriLux RF control GPIO option "ALux IrSel" (159) replacing "Led4i" (59) for full LED control (#5709)
* Add LED GPIO option "LedLink" (157) and "LedLinki" (158) to select dedicated link status LED (#5709)
* Add support for up to four LEDs related to four power outputs. Enabled when "LedLink(i)" is configured too (#5709)
* Add extended LED power control using command LedPowerX where X is 1 to 4. Enabled when "LedLink(i)" is configured too (#5709)
6.5.0.11 20190517
* Add command SetOption64 0/1 to switch between "-" or "_" as sensor index separator impacting DS18X20, DHT, BMP and SHT3X sensor names (#5689)
6.5.0.11 20190517
* Add user define INDEX_SEPARATOR to control Sensor Name index character which was fixed to "-" (minus) but is now changed to "_" (underscore) for future support.
* This change impacts DS18X20, DHT, BMP and SHT3X sensor names.
6.5.0.10 20190513
* Enable ADC0 by default in my_user_config.h (#5671)
* Add user configurable ADC0 to Module and Template configuration compatible with current FLAG options (#5671)
6.5.0.6 20190409
* Add WebColor parameters to Settings making them persistent and remove the need for using a rule
* Add alternative IRSend command syntax IRSend raw,<freq>,<header mark>,<header space>,<bit mark>,<zero space>,<one space>,<bit stream> (#5610)
6.4.1.14 20190203
* Add SetOption32 until SetOption49 diagnostic information to Status 3 report as replacement for second property value in SetOption property name
* Add Resolution property to Status 3 report providing previous SetOption second value property
6.4.1.11 20190124
* Remove command SetOption14 as it has been superseded by command Interlock
* Remove command SetOption63 as it has been superseded by command Interlock
* Add command Interlock 0 / 1 / 1,2 3,4 .. to control interlock ON/OFF and add up to 8 relays in 1 to 4 interlock groups (#5014)
6.4.1.8 20190107
* Change sonoff_template.h layout regarding optional module flags like ADC0
* Add command SetOption62 1 to force no Button/Switch pullup on dedicated modules. Currently only supported on Shelly2 (#4841)