* Added Console Commands to send KNX Commands
usage: KnxTx_Cmnd[slot] command
where [slot] is any of the 5 slots on the KNX Menu and command is 0 or 1
example: KnxTx_Cmnd1 0
* Added Console Commands to send KNX Values
usage: KnxTx_Val[slot] value
where [slot] is any of the 5 slots on the KNX Menu and value is a number
example: KnxTx_Val1 35
* Added Slots on the KNX Web Menu to select Group Addess to send data from console commands
* Added Events to trigger rules when received data from KNX
usage on rules as: event#KnxRx_Val[slot]
where [slot] is any of the 5 slots on the KNX Menu
example: rule on event#KnxRx_Val1 do VAR1 %value% endon
* Added Events to trigger rules when received read requests from KNX
usage on rules as: event#KnxRx_Req[slot]
where [slot] is any of the 5 slots on the KNX Menu
example: rule on event#KnxRx_Req1 do KnxTx_Val1 35 endon
* Added Slots on the KNX Web Menu to select Group Addess to receive data to trigger rules
5.14.0a
* Add KNX energy data (#2750)
* Fix display selection of
un-available GPIO options in Module Configuration webpage (#2718)
* Fix
IRSend not accepting data value of 0 (#2751)
Add control by KNX for all Tasmota Outputs
Before this commit, only Relays were able to be controlled by KNX. Now all Outputs can be controlled using KNX.
5.12.0m
* Remove sonoff-xxl
* Add sonoff-classic, sonoff-allsensors and sonoff-knx
* Add some coloring to important web buttons
* Add user selectable defines for Sunrise/set Dawn option (#2378)
* Add GPIO_User to GPIO02 for all Sonoff T1 (#2524)