Commit Graph

9276 Commits

Author SHA1 Message Date
Theo Arends a30f47a901 Fix bad define ESP82666 2024-09-19 11:07:16 +02:00
Theo Arends a5730a76f9 Add command entered to command error and command unknown message 2024-09-17 16:24:45 +02:00
Theo Arends 4f2b24f53d Add entered command to MQTT command unknown message (bis) 2024-09-17 10:19:00 +02:00
Theo Arends fd7d2fc0a4 Add entered command to MQTT command unknown message 2024-09-17 10:00:47 +02:00
Theo Arends 97970974fc Refactored I2C drivers HTU21, BH1750 and HYT 2024-09-16 16:27:30 +02:00
Theo Arends c61dd0fd2c Minor refactor I2C 2024-09-15 15:16:18 +02:00
Theo Arends a3892ecbc4 Update change logs 2024-09-14 16:13:14 +02:00
s-hadinger 1bfbe02a29
Berry I2C to prepare M5Stack I2C STM32 based devices (#22143) 2024-09-14 12:25:23 +02:00
Theo Arends 1dff0b4b27 Add support for RX8010 RTC as used in IOTTIMER (#21376) 2024-09-13 13:53:01 +02:00
s-hadinger 6e4517de02
Berry virtual Energy driver (#22134) 2024-09-12 19:38:04 +02:00
Theo Arends 7b8308c36a Add support for I2C M5Unit (Mini)Scales using HX711 driver 2024-09-12 12:14:32 +02:00
s-hadinger 9d012f64c8
Add internal I2C argument to send stop while reading (#22127) 2024-09-11 16:41:35 +02:00
Pavel Sheremetev 1edc4b57b7
allow define calibration parametrs for bl09xx (#22030)
Co-authored-by: PavelSheremetev <spd@aira.life>
2024-09-11 08:55:43 +02:00
Theo Arends d8f01ed4c0 Refactor HX711 memory use 2024-09-10 15:59:25 +02:00
stefanbode 05e59b048e
Fix remaining issues on shutterinvert (#22120)
found another place where the invert was not reported correctly
2024-09-10 14:48:51 +02:00
gemu 1c730aab86
fix trx pin error (#22119) 2024-09-10 14:48:38 +02:00
s-hadinger 2d522485c4
Zigbee fix flashing CC2562P with latest firmware (#22117) 2024-09-09 21:56:18 +02:00
s-hadinger 7247cd6c44
Fixed Berry energy missing attributes (#22116) 2024-09-09 21:50:06 +02:00
Damian Wrobel 6650dee578
Fix ModbusBridge request/response logic (#22075)
- Fix cases where the subsequent Modbus packet
  can be send to the serial port (triggered either by
  'ModbusSend' command or request from TCP bridge)
  before an answer was received to the previous packet.

  This can happen in a setup where simultaneously:
  - two (or more) modbus TCP clients are sending requests
    through the modbus-proxy [1] to Tasmota,
  - ModbusSend commands are executed (e.g. using Berry).

  Log excerpt (from build with TASMOTAMODBUSDEBUG enabled):
  14:51:18.940 MBS: Serial Send: 04 03 01 00 00 09 84 65
  14:51:19.054 MBS: Serial Send: 04 03 10 0A 00 05 A1 5E
  14:51:19.136 MBS: Serial Received: 04 03 0A 00 00 00 D0 00 00 01 AB 00 00 89 62

  Fix adds 'waitingForAnswerFromSerial' flag which is set after
  we send data to the serial port and prevents sending another
  requests before we receive an answer or timeout happened.

  Fix stores temporarily a 'ModbusSend' command data and tries
  to execute it after Modbus response has been received or
  timeout has happened.

- Add 'ModbusSerialTimeout' command which sets timeout in [ms]
  for how long we will be waiting for an answer from the client device.
  Default value is 1000 [ms] and it is not restored after reboot.

- Sends error 11 (0xB) (as TCP response) when no answer was received
  from the serial port within the timeout set by 'ModbusSerialTimeout'
  command.

- Add Modbus 'TransactionId' to the logging.

[1] https://github.com/tiagocoutinho/modbus-proxy

Signed-off-by: Damian Wrobel <dwrobel@ertelnet.rybnik.pl>
2024-09-09 10:26:20 +02:00
pbrinette 28bbf11dbb
Enhance the KNX capabilities of Tasmota to offer more flexibility and features (#22071) 2024-09-09 09:25:11 +02:00
s-hadinger 9ac2a69603
Matter support for Zigbee Occupancy and Light 0/1/2 (OnOff / Dimmer / White Color Temperature) (#22110) 2024-09-08 23:16:19 +02:00
Theo Arends 1bf6a13d7c Bump version v14.2.0.4
- Add HX711 optional calibration precision option on command ``Sensor34 2 <weight in gram> <precision>`` where `<precision>` is 1 to 10 (#13983)
2024-09-08 17:32:35 +02:00
stefanbode 744e50acf7
Fix missing HOLD on shutterbutton (#22108)
#21986
2024-09-08 16:50:37 +02:00
gemu 2c5e8749e3
multi trx lines (#22056) 2024-09-07 15:29:27 +02:00
Jason2866 069f59d13f
remove irritating space (#22095) 2024-09-05 16:51:45 +02:00
s-hadinger 5f80251414
Berry Zigbee improvements to prepare Matter (#22083) 2024-09-03 23:22:50 +02:00
s-hadinger 4164887412
Zigbee avoid disabling console serial on ESP32 and improved log messages (#22082) 2024-09-03 23:06:07 +02:00
s-hadinger b6e81c1edd
Zigbee Koenkk firmware 20240710 for Sonoff Zigbee ZBPro (#22076) 2024-09-02 22:20:41 +02:00
Steffen caa501b1af
add support for nexus protocol to rc-switch library (#21886)
* add support for nexus protocol to RCSwitch library

Nexus protocol is used by temperature and humidity sensor that operate at 433 MHz.
It is used by various brands.

* calc separation limit for RCSwitch library automatically
2024-09-01 16:04:40 +02:00
s-hadinger 11ed65560b
LVGL Added OpenHASP icons to font `montserrat-28` (#22048) 2024-08-29 16:57:01 +02:00
s-hadinger e7f120d443
Berry make `energy` modules changes from #21887 backwards compatible (#22046) 2024-08-29 16:02:14 +02:00
s-hadinger e8cdeaba6b
ESP32 LVGL library from v9.1.0 to v9.2.0 (#22031) 2024-08-27 23:36:38 +02:00
Theo Arends a10e3b9bc5 GPIOViewer function shuffle. No functional changes 2024-08-26 16:48:39 +02:00
Theo Arends 969611835c Fix GPIOViewer on ESP32 (needs upcoming core change) 2024-08-26 15:26:36 +02:00
Theo Arends f0c12b6e9c Remove dash from GUI title 2024-08-26 14:20:51 +02:00
Theo Arends fefd49c663 Remove dash from GUI title 2024-08-26 14:14:59 +02:00
pkkrusty 88c9ae3273
Clarify MAX7219 display driver (#21977)
MAX7219 and MAX7219_MATRIX are different displays and require different defines. DisplayModel19 incorrectly listed for MAX7219 instead of MAX7219_MATRIX.
2024-08-26 08:49:48 +02:00
gemu c35c493809
i2s wav player (#22003)
* i2s wav player

* move framepointer
2024-08-26 08:48:35 +02:00
s-hadinger 645ce4a1ee
Zigbee reduce serial logging (#22012) 2024-08-24 23:53:42 +02:00
s-hadinger d084be23db
Zigbee extend timeout for MCU reboot from 5s to 10s (#22009) 2024-08-24 18:32:35 +02:00
Theo Arends 831597e7d9 Version v14.2.0.3
- Add command ``SetOption69 1`` to enable Serial Bridge inverted Receive (#22000)
2024-08-23 11:22:26 +02:00
Theo Arends 4144f5c5ca Change GPIOViewer from v1.5.5 to v1.5.6 2024-08-22 18:03:39 +02:00
Theo Arends 798edc20c2 Version v14.2.0.2
- Changed Energy BL09xx command ``CurrentSet`` input changed from Ampere to milliAmpere
2024-08-21 16:27:43 +02:00
Theo Arends ba7161fb00 Fix ESP8266 energy cal range chk 2024-08-20 17:30:18 +02:00
Theo Arends ab2d6c1169 Add Energy command ``PowerSet 60,230`` to calibrate both Current and Power with known resistive load of 60W at 230V using calibrated Voltage 2024-08-20 13:08:56 +02:00
Theo Arends c5b92d3ab1 Add Energy Log level 4 message when (Calculated) Apparent Power is less than Active Power indicating wrong calibration (#20653) 2024-08-19 22:31:56 +02:00
Theo Arends 4f62a0deab Refactor to TimeReacged() 2024-08-18 12:46:23 +02:00
Theo Arends e74142724c Disable 64-bit timing support 2024-08-18 12:13:44 +02:00
Theo Arends 903686f7b5 Add 64-bit timing support 2024-08-16 11:56:07 +02:00
Theo Arends c0eb28dae9 Harden shutter timeouts 2024-08-16 11:53:58 +02:00