Commit Graph

59 Commits

Author SHA1 Message Date
Theo Arends 8ffff8b857 Change Tasmota OTA scripts
Change Tasmota OTA scripts now support both unzipped and gzipped file uploads (#17378)
2022-12-21 17:22:54 +01:00
Theo Arends b332029664 Create upload-tasmota.php 2022-12-13 14:56:46 +01:00
Theo Arends 66909f7cec Add support for gzipped binaries
Add support for gzipped binaries
2020-01-06 16:10:44 +01:00
Theo Arends 1c6af967be Add program to decode some status messages
5.14.0a
* Add feature information to Status 4
* Add tools folder with python script decode-status.py for decoding some
status fields like SetOption and Features
* Add python script fw-server.py in tools folder to create a simple OTA
server (#2759)
* Fix vars on rules (#2769)
* Fix bug in KNX menu (#2770)
2018-05-19 17:31:55 +02:00
Gennaro Tortone 0356a90805 fw-server: add ip option 2018-05-17 18:03:02 +02:00
Theo Arends f095b4818c Add python firmware server
Python firmware server can provide binary OTA images to Tasmota. See
README for usage. Tested on Linux.
2018-05-17 16:13:30 +02:00
arendst 44b69bfd97 v5.1.4
5.1.4 20170601
* Removed pre-compiled versions from repository as they are available
within the release
* Changed HUE Device type to color supporting version (#464)
* Fix compile error when BE_MINIMAL is selected (#467, #476)
* Add multiple compiled versions to release using updated Travis script
and platformio.ini (#467)
2017-06-01 17:37:30 +02:00
arendst 70ccdfe9b9 v5.1.3
5.1.3 20170520
* Add Domoticz Counter
2017-05-20 14:03:34 +02:00
arendst 26d3a8c191 v5.1.2
5.1.2 20170519
* Fix Counter/Timer JSON message and update Counter/Timer on webpage
* Fix WS2812 Domoticz related regression issues
2017-05-19 16:09:25 +02:00
arendst 88648a8099 v5.1.1
5.1.1 20170517
* Allow command FullTopic in group mode
* Prepare for more use of RTC memory
* Add independant WS2812 led string power control (#386, #390)
* Add command Counter<x> to control up to four GPIO falling edge
interrupt counters or timers (#459)
* Add command CounterType<x> to select between pulse counting or pulse
timing
* Add command CounterDebounce to select global counter debounce time in
mSec
2017-05-17 22:49:22 +02:00
arendst f6f6616c9d v5.1.0
5.1.0 20170513
* Fix Offline/Removal of retained topic when FullTopic is changed
* Add FullTopic to MQTT Configuration and Information web page
* Adde license model GPLv3 (#188)
2017-05-13 13:02:10 +02:00
arendst 103c5606ac v5.0.7
5.0.7 20170511
* Fix possible exception 28 on empty command
* Add command SetOption0 as replacement for SaveState
* Add command SetOption1 as replacement for ButtonRestrict
* Add command SetOption2 as replacement for Units
* Add command SetOption4 as replacement for MqttResponse
* Add command SetOption8 as replacement for TempUnit
* Add command SetOption10 On|Off to select between Offline or Removing
previous retained topic (#417, #436)
2017-05-11 17:47:34 +02:00
arendst 32c3a66ead v5.0.6
5.0.6 20170510
* Remove hyphen in case of a single DHT sensor connecetd (#427)
* Add command MqttRetry <seconds> to change default MQTT reconnect retry
timer from minimal 10 seconds (#429)
2017-05-10 14:19:36 +02:00
arendst bc9d44d74a v5.0.5
5.0.5 20170508
* Add command FullTopic with tokens %topic% (replaced by command Topic
value) and
*  %prefix% (replaced by command Prefix<x> values) for more flexible
topic definitions (#244)
*  See wiki > MQTT Features
https://github.com/arendst/Sonoff-Tasmota/wiki/MQTT-Features for more
information
2017-05-08 13:21:45 +02:00
arendst 7ce5b4cba5 v5.0.4
5.0.4 20170505
* Add Sonoff Pow Energy Total up to 40 MWh
* Add command EnergyReset 1|2|3 to reset Energy counters (#406)
* Fix Domoticz Energy logging (#411)
* Add command PowerOnState 4 to keep relay always on and disabling all
power control (#418)
2017-05-05 17:57:05 +02:00
arendst 77da1dfdc1