Commit Graph

57 Commits

Author SHA1 Message Date
arendst c82fe7f46e v5.8.0f - Add inverted PWM support
5.8.0f
 * Set all saved power settings to Off when SetOption0
(SaveState) = 0 (#955)
 * Allow PWM initialization after restart (#955)

* Add support for inverted PWM (#960)
2017-10-04 17:29:49 +02:00
arendst 48faeaa2ce v5.8.0d - Add Color/Dimmer control to PWM
5.8.0d
 * Remove previous GPIO configuration when another module is
selected
 * Fix inverted relay power on state (#909)
 * Change default
PWM assignments for H801 RGB(CW) led controller to support optional
Color/Dimmer control
 *   GPIO04 (W2)    from GPIO_PWM2 to GPIO_USER to
be user configurable for GPIO_PWM5 (second White - Warm if W1 is Cold)

*   GPIO12 (Blue)  GPIO_PWM3 no change
 *   GPIO13 (Green) from
GPIO_PWM4 to GPIO_PWM2
 *   GPIO14 (W1)    from GPIO_PWM1 to GPIO_USER
to be user configurable for GPIO_PWM4 (first White - Cold or Warm)
 *
GPIO15 (Red)   from GPIO_PWM5 to GPIO_PWM1
 * Change default PWM
assignments for MagicHome RGB(W) led controller to support optional
Color/Dimmer control
 *   GPIO05 (Green) from GPIO_PWM4 to GPIO_PWM2
 *
GPIO12 (Blue)  from GPIO_PWM5 to GPIO_PWM3
 *   GPIO13 (White) GPIO_USER
to be user configurable for GPIO_PWM4 (White - Cold or Warm)
 *   GPIO14
(Red)   from GPIO_PWM3 to GPIO_PWM1
 * Add command SetOption15 0
(default) for command PWM control or SetOption15 1 for commands
Color/Dimmer control to PWM RGB(CW) leds (#941)
2017-10-01 14:32:36 +02:00
arendst 107b746083 v5.8.0c
5.8.0c
 * Add warning to webpage when USE_MINIMAL is selected (#929)
 *
Fix compile error when DOMOTICZ_UPDATE_TIMER is not defined (#930)
 *
Fix alignment of web page items in some browsers (#935)
 * Add smoother
movement of hour hand in WS2812 led clock (#936)
 * Add support for
Magic Home RGBW Led controller (#940)
2017-09-30 13:32:53 +02:00
arendst e974dcb7b7 v5.8.0b - Add Domoticz Voltage and Current
5.8.0b
 * Fix command FullTopic entry when using serial or console
interface
 * Fix possible UDP syslog blocking
 * Add debug information
to MQTT subscribe
 * Add Domoticz sensors for Voltage and Current (#903)
2017-09-26 15:10:58 +02:00
arendst 2d5fc29976 v5.7.1e - Add Sonoff SC debugging
5.7.1e
 * Add Sonoff SC debug information
 * Change syslog service
2017-09-14 14:20:27 +02:00
arendst c16fd3d99e v5.7.1d
5.7.1d
 * Fix watchdog timeout caused by lack of stack space by now
using global buffers (#853)
 * Removed webserver syslog disable as now
no longer needed
 * Increased default MQTT message size from 368 to 405
bytes while keeping DMQTT_MAX_PACKET_SIZE = 512 (because we can)
 * Fix
MQTT Offline or Remove MQTT retained topic code
 * Allow command
SwitchTopic in group mode (#861)
 * Allow command SwitchMode if no
switches are defined (#861)
2017-09-13 14:19:34 +02:00
arendst 4f6acfa7d9 v5.7.0a - Add optional # to color
5.7.0a
 * Remove leading spaces from MQTT data
 * Fix webconsole special
character entry
 * Allow # as prefix for color value
2017-09-08 12:57:08 +02:00
arendst ee914714ab v5.6.1l - Tried to fix excepetion 3
5.6.1l
* Fix some string length issues
* Add more string length tests by using strncpy
* Tried to fix Exception 3 as I can't reproduce (#830)
2017-09-06 17:37:41 +02:00
arendst 0fbbc23b2c Add I18n and fix invalid JSON
5.6.1i
* Add basic internationalization and localization (#763)
* Fix invalid JSON (#822)
2017-09-02 14:37:02 +02:00
arendst dbab55758a Shrink module configuration webpage 2017-08-19 16:29:51 +02:00
arendst d96191888d v5.6.1
5.6.1 20170818
* Change module list order in webpage
* Fix Sonoff T1 1CH and 2CH configuration (#751)
*
* 5.6.0 20170818
* Fix Sonoff Pow intermittent exception 0
* Change Sonoff Pow sending Domoticz telemetry data only
* Add Ai-Thinker RGBW led (AiLight) (experimental)
* Add NeoPixelBus library to Sonoff Led for Hue support
* Add user configurable GPIO4 and GPIO5 to module Sonoff Bridge
* Add Sonoff B1 RGBCW led support with command Color RRGGBBCCWW (#676)
* Add command CT 152..500 to Sonoff Led and Sonoff B1 to control Color
Temperature
* Add Cold-Warm slider to web page for Sonoff Led and Sonoff B1
* Add CT parameter to Hue
* Add Sonoff T1 support (#582)
* Add AnalogInput0 if configured as Analog Input to webpage (#697, #746)
* Add command SetOption14 0|1 to enable interlock mode (#719, #721)
* Fix Mitsubishi HVAC IR power controll (#740)
2017-08-18 18:04:49 +02:00
arendst fa0b7d7784 v5.6.0
5.6.0 20170818
* Fix Sonoff Pow intermittent exception 0
* Change Sonoff Pow sending Domoticz telemetry data only
* Add Ai-Thinker RGBW led (AiLight) (experimental)
* Add NeoPixelBus library to Sonoff Led for Hue support
* Add user configurable GPIO4 and GPIO5 to module Sonoff Bridge
* Add Sonoff B1 RGBCW led support with command Color RRGGBBCCWW (#676)
* Add command CT 152..500 to Sonoff Led and Sonoff B1 to control Color
Temperature
* Add Cold-Warm slider to web page for Sonoff Led and Sonoff B1
* Add CT parameter to Hue
* Add Sonoff T1 support (#582)
* Add AnalogInput0 if configured as Analog Input to webpage (#697, #746)
* Add command SetOption14 0|1 to enable interlock mode (#719, #721)
* Fix Mitsubishi HVAC IR power controll (#740)
2017-08-18 14:52:57 +02:00
arendst ebee148be8 Add Sonoff B1 features 2017-08-16 17:05:36 +02:00
arendst c0b1ceba8b v5.5.2
5.5.2 20170808
* Extent max number of WS2812 pixels from 256 to 512 (#667)
* Add OTA handling if server responds with no update available (#695)
* Removed undocumented command FlashMode (#696)
* Fix compile time error message due to increased message buffer size
(#703)
2017-08-08 16:31:43 +02:00
Theo Arends 05073b7ab7 Revert "Ota remove flash mode" 2017-08-08 16:08:08 +02:00
Theo Arends eab7250102 v5.5.1b
5.5.1b
 * Extent max number of WS2812 pixels from 256 to 512 (#667)
 * Add OTA handling if server responds with no update available (#695)
 * Removed undocumented command FlashMode (#696)
 * Fix compile time error message due to increased message buffer size (#703)
2017-08-08 14:50:21 +02:00
arendst 0a9ec10b0a v5.5.0
5.5.0 20170730
* Reduce code space by removing the following commands as they are
replaced by SetOption alternatives:
*   SaveState = SetOption0
*   ButtonRestrict = SetOption1
*   Units = SetOption2
*   MQTT = SetOption3
*   MQTTResponse = SetOption4
*   TempUnit = SetOption8
* Smoothing WS2812 animation poll, invert fade speed and max allowed
wakeup time down to 3000 seconds
* Fix initial button press detection
* Add support for Sonoff RF Bridge 433 using command RfKey
* Fix regression from 5.0.7 by increasing message buffer size from 360
to 368 to accomodate 4 x DS18x20 sensors (#637)
* Add GroupTopic to Topic test when using ButtonTopic/SwitchTopic to
send either ON/OFF or TOGGLE (#642)
* Adjust HLW calibration limits to accomodate HuaFan device and add
commands HlwPSet, HlwUSet and HlwISet (#654)
2017-07-30 17:55:37 +02:00
arendst 7e6b3a2bb1 v5.3.0
5.3.0 20170715
* Major Hue rewrite which might introduce Alexa problems. If so,
initiate an issue
* Add support for Sonoff Led and BN-SZ01 Ceiling Led brightness control
to Hue
* Fix Sonoff Led Power, Dimmer and Color MQTT response (#176)
* Add commands Delay and Backlog to allow multiple commands at once
separated by ";" (#593)
* Use default flashmode DOUT to solve restart hangs on esp8285 chips
(#453, #598)
* Change Web console column width from 99 to 300 (#599)
2017-07-15 15:07:30 +02:00
arendst 39a65e230b v5.2.4
5.2.4 20170703
* Removed flash mode update after selecting different module solving
esp8285 related problems
* Add device type flag to sonoff_template.ino
* Change Sonoff Led Wakeup and add support for Sonoff BN-SZ01 Led
2017-07-03 11:45:15 +02:00
arendst 2195ddd496 v5.2.2
5.2.2 20170625
* Add configuration SaveAddress to Status 1 and Information Page
* Change Sonoff Led Color conversion from AtoH to strtol
* Fix possible wrong uploads due to configuration overwrites (#542)
* Fix payload negative numbers (#547)
2017-06-25 23:01:41 +02:00
arendst 92958f4bdd v5.2.1
5.2.1 20170622
* Fix Restore Configuration in case of lower version
* Revert auto configuration upgrade allowing easy upgrade which was
removed in version 5.2.0
* Fix config auto upgrade from versions below version 4.1.1 (#530)
2017-06-22 22:00:09 +02:00
arendst b88ec7f5a9 v5.2.0
5.2.0 20170619
* Add command SetOption12 1 to disable newly released configuration
flash rotate to reduce flash wear
* Fix command CounterDebounce by removing test for active GPIO (#524)
* Add command SetOption33 1..250 to allow user configure POW
Max_Power_Retry count (#525)
2017-06-19 22:54:49 +02:00
arendst d763fd52eb v5.1.7
5.1.7 20170616
* Prep removal of SetOptions alternatives
* Restore webpage upgrade error messages removed in 5.1.5
* Add hold button functionality to buttons 2 to 4
* Add command SetOption32 1..100 to set Key Hold Time from 0.1 seconds
to 10 seconds (#200)
* Allow slashes in Topic, GroupTopic, ButtonTopic and SwitchTopic (#507)
* Changed webpage form actions from post to get and use relative path
url (#434, #522)
2017-06-16 14:33:49 +02:00
arendst 0f103db4c6 v5.1.5
5.1.5 20170604
* Shrink code in preparation to ESP8266-Arduino 2.4.0-rc1
* Add effect parameter to HUE Device (#464)
2017-06-04 17:40:27 +02:00
arendst 70ccdfe9b9 v5.1.3
5.1.3 20170520
* Add Domoticz Counter
2017-05-20 14:03:34 +02:00
arendst 26d3a8c191 v5.1.2
5.1.2 20170519
* Fix Counter/Timer JSON message and update Counter/Timer on webpage
* Fix WS2812 Domoticz related regression issues
2017-05-19 16:09:25 +02:00
arendst 88648a8099 v5.1.1
5.1.1 20170517
* Allow command FullTopic in group mode
* Prepare for more use of RTC memory
* Add independant WS2812 led string power control (#386, #390)
* Add command Counter<x> to control up to four GPIO falling edge
interrupt counters or timers (#459)
* Add command CounterType<x> to select between pulse counting or pulse
timing
* Add command CounterDebounce to select global counter debounce time in
mSec
2017-05-17 22:49:22 +02:00
arendst f6f6616c9d v5.1.0
5.1.0 20170513
* Fix Offline/Removal of retained topic when FullTopic is changed
* Add FullTopic to MQTT Configuration and Information web page
* Adde license model GPLv3 (#188)
2017-05-13 13:02:10 +02:00
arendst 103c5606ac v5.0.7
5.0.7 20170511
* Fix possible exception 28 on empty command
* Add command SetOption0 as replacement for SaveState
* Add command SetOption1 as replacement for ButtonRestrict
* Add command SetOption2 as replacement for Units
* Add command SetOption4 as replacement for MqttResponse
* Add command SetOption8 as replacement for TempUnit
* Add command SetOption10 On|Off to select between Offline or Removing
previous retained topic (#417, #436)
2017-05-11 17:47:34 +02:00
arendst 32c3a66ead v5.0.6
5.0.6 20170510
* Remove hyphen in case of a single DHT sensor connecetd (#427)
* Add command MqttRetry <seconds> to change default MQTT reconnect retry
timer from minimal 10 seconds (#429)
2017-05-10 14:19:36 +02:00
arendst c61a39a06d v5.0.2
5.0.2 20170503
* Reset SaveData, SaveState and MqttResponse to default values due to
rearranging settings
* Moved some settings flag area
* Add command TempUnit Celsius|Fahrenheit for selecting Celsius or
Fahrenheit (#347)
* Add command TempRes 0..3 for selecting Temperature Resolution (#347)
* Add command HumRes 0..3 for selecting Humidity Resolution (#347)
* Add command PressRes 0..3 for selecting Pressure Resolution (#347)
* Add command EnergyRes 0..5 for selecting Energy Resolution (#347)
* Add "TemperatureUnit":"C|F" to sensor JSON output (#347)
* Add support for up to three DHT type sensors each using a different
GPIO (#339, #404)
2017-05-03 18:19:13 +02:00
arendst ecc6bb5fdc v5.0.0
5.0.0 20170425
* Memory status message update
* Fix setting migration to better preserve settings during move (#382)
* Best practice is first doing a Backup Configuration before installing
version 5.0.0
* Reset save count after setting move
* Start using new linker script without SPIFFS
2017-04-25 18:24:42 +02:00
arendst 79b63858b9 v4.1.3
4.1.3 20170410
* Add user configuarble GPIO to module S20 Socket and Slampher
* Add support for Sonoff SC (#112)
* Set PWM frequency from 1000Hz to 910Hz as used on iTead Sonoff Led
firmware (#122)
* Set Sonoff Led unconfigured floating outputs to 0 to reduce exceptions
due to power supply instabilities (#122)
* Add Access Point Mac Address to Status 11 and Telemetry (#329)
* Fix DS18B20 negative temperature readings (#334)
2017-04-10 17:33:57 +02:00
arendst 824368125b v4.1.3
4.1.3 20170410
* Add user configuarble GPIO to module S20 Socket and Slampher
* Add support for Sonoff SC (#112)
* Set PWM frequency from 1000Hz to 910Hz as used on iTead Sonoff Led
firmware (#122)
* Set Sonoff Led unconfigured floating outputs to 0 to reduce exceptions
due to power supply instabilities (#122)
* Add Access Point Mac Address to Status 11 and Telemetry (#329)
* Fix DS18B20 negative temperature readings (#334)
2017-04-10 17:25:31 +02:00
arendst fcb380ce2c v4.1.2
4.1.2 20170403
* Rename Unrecognised command to Unknown command
* Remove all command lists
* Remove command SmartConfig (superseded by WifiConfig)
* Fix boot loop when selecting module Sonoff 4CH or Sonoff Touch on non
ESP8285 hardware
* Add optional support for Toshiba and Mitsubishi HVAC IR control (needs
updated IRanother  (#257)
* Add all configured switches to Domoticz Configuration web page (#305)
* Fix compile error when selecting WS2812 DMA (#313)
2017-04-03 16:38:15 +02:00
arendst a8f2293a66 v4.1.1
4.1.1 20170329
* Fix default Telemetry for command Prefix3
* Fix webserver Module parameters for disabled select
* Fix sensor status for enabled switches
* Remove Light as alternative for Power (save code space)
* Remove migration option from pre V3 (code cleanup)
* Remove unofficial SPIFFS support (code cleanup)
* Remove command list when unknown command is entered (save code space)
* Rename Status11 json from StatusPWR to unique StatusSTS
* Rename command Gateway to IPAddres2, Subnetmask to IPAddress3 and
DnsServer to IPAddress4 (save code space)
* Add Command MqttResponse to select either command or RESULT topic as
response (#258)
* Add command StateText1 to StateText3 to assign MQTT_STATUS_OFF,
MQTT_STATUS_ON and MQTT_CMND_TOGGLE respectively (#286)
* Remove restart after IPAddress changes (#292)
* Add support for MAX31850 in xsns_ds18x20.ino (#295)
* Fix possible uptime update misses (#302)
2017-03-29 18:42:05 +02:00
arendst ae27ec26a4 v4.1.0
4.1.0 20170325
* Change static IP addresses in user_config.h from list (using commas)
to string (using dots)
* Unify display result of commands Modules, Module and Gpios
* Rewrite Module selection web page to bring size down from 18651 to
4319 bytes (!) (#234, #240)
* Add basic support for (Lixada) H801 RGBWW controller (#252)
* Add command Prefix1 to Prefix3 to assign SUB_PREFIX, PUB_PREFIX and
PUB_PREFIX2 respectively (#255)
* Add static ip addresses to flash (#262)
* Add commands IpAddress, Gateway, Subnetmask and DnsServer to select
static ip addresses (#273)
2017-03-25 17:24:11 +01:00
arendst 99b7474ac4 v4.0.8
4.0.8 20170321
* Fix entering non-numeric webpassword
* Force selection between TLS or Webserver due to memory restraint
(#240)
* Allow entering empty string using "0" for selected commands (#242)
* Fix exception when posting commands to web console containing % (#250)
2017-03-21 16:17:28 +01:00
arendst 742a87df8a v4.0.7
4.0.7 20170319
* Increased Sonoff Led PWM frequency from 432 to 1000
* Fix possible watch dog reboot after changing module type on web page
* Fix reporting of GPIO usage from web page
* Fix Sonoff Led blank during firmware upgrade
* Fix Sonoff Led flicker and possible flash corruption by using latest
Arduino-esp8266 versions
*   of pwm core files included in sonoff library (#211)
* Add PWM output control with commands PWM1 to PWM5 using user
selectable GPIOs (#211)
* Fix exceptions due to low values of commands HlwPCal (10000), HlwUCal
(1000) and HlwICal (2500) (#223)
* Add Switch state to sensor status (#227, #233)
* Add user configuarble GPIO to module Sonoff Touch (#228)
* Add define WEB_PORT to user_config.h to change default web server port
from 80 (#232)
* Fix failed Ota Firmware upgrade started from Web page (#235)
2017-03-19 18:19:08 +01:00
arendst c4cdd4459c v4.0.6
4.0.6 20170316
* Fix to better find device by Wifi hostname
* Fix compile error when some I2C devices are disabled
* Add (experimental) support for SHT1X emulating I2C (#97)
* Add ADC to ElectroDragon (#203)
* Add support for Sonoff Dev (#206)
2017-03-16 16:23:11 +01:00
arendst 59bb20d2cb v4.0.3
4.0.3 20170309
* Renamed Module NodeMCU to WeMos D1 mini
* Add GPIO1 as user option to some modules
* Add Buttons, Relays and Leds to user configurable options (#159)
* Add description on Module parameters web page to some well known GPIOs
(#107, #171)
2017-03-09 17:48:04 +01:00
arendst ac84010015 v4.0.2
4.0.2 20170308
* Restore correct seriallog level after Serial logging was disabled
* Add simple dimmer slider to Sonoff Led web page
* Reduced root webpage size by 31%
* Expand Status 2 with Build date/time and core version
* Fix webserver redirection when not in WifiManager mode (#156)
* Add command ButtonRestrict On/Off to restrict access to button hold
and button multi press options above 2 (#161)
* Fix DS18S20 negative temperature readings (#165)
* Fix crlf compilation error due to bad syntax (#144, #167)
2017-03-08 16:20:45 +01:00
arendst 47d711b1b2 v4.0.1
4.0.1 20170305
* Fix char default sizes and set MESSZ to 360 (#143)
* Fix SerialLog setting status
* Disable syslog when emulation is active
* Add DS18B20 web page display refresh
2017-03-05 15:07:30 +01:00
arendst acb5252b54 v4.0.0
4.0.0 20170303
* Add define to remove config migration code for versions below 3.0 (See
Wiki-Upgrade-Migration path)
* Free memory by switching from String to char[]
* Raised Sonoff Led PWM frequency from 200Hz to 432Hz in search of
stability (hardware watchdog timeouts) (#122)
* Increase message size and suggested minimum MQTT_MAX_PACKET_SIZE to
512 (#114, #124)
* Remove runtime warning message regarding MQTT_MAX_PACKET_SIZE too
small as it is now moved to compile time (#124)
* Fix possible panics with web console and http commands while UDP
syslog is active (#127)
* Add optional static IP address (#129)
* Add define ENERGY_RESOLUTION in user_config.h to allow user control
over precision (#136)
2017-03-03 12:35:23 +01:00
arendst fc3b7e22ab v3.9.22
3.9.22 20170228
* Update web console
* Fix Status 4 JSON message
* Add Exception info during restart if available
* Add osWatch service to detect loop hangs that might happen during
(OTA) upgrades
* Add WiOn support for relay and switch only (#82, #102)
* Allow for user specified relay count up to four in sonoff_template.h
(#109)
* Add support for HTU21 compatible I2C sensors SI7013, SI7020 and SI7021
(#118)
* Add NodeMCU or Wemos configuration option (#119)
2017-02-28 16:01:48 +01:00
arendst 3fefb9b931 v3.9.21
3.9.21 20170224
* Add ajax to web root page and web console (#79)
* Add commands SwitchMode1..4 and enable user switches 2, 3 and 4 (#84,
#88)
* Fix MQTT upgrade when webserver is active
2017-02-24 18:17:48 +01:00
arendst 3f73e48bfa v3.9.20
3.9.20 20170221
* Add minimal basic authentication to Web Admin mode (#87)
* Fix Hue and add HSB support (#89)
2017-02-21 18:14:33 +01:00
arendst 18aaf05622 v3.9.19
3.9.19 20170219
* Sonoff Led: Made GPIO04, 05 and 15 available for user
* Sonoff Led: Add commands Fade, Speed, WakupDuration, Wakeup and
LedTable
2017-02-19 17:49:17 +01:00
arendst 3997f48809 v3.9.18
3.9.18 20170218
* Fix ledstate 0 to turn off led
* Fix Sonoff Led dimmer range (#16)
* Change Sonoff Led command Dimmer to act on both cold and warm color
* Add Sonoff Led command Color CCWW where CCWW are hexadecimal values
fro 00 - FF
* Reduce Sonoff Led flickering by disabling interrupts during flash save
and disabling
*   Led during OTA upgrade and Web upload (#16)
2017-02-18 18:08:55 +01:00
arendst edca508f57 v3.9.17
3.9.17 20170217
* Fix possible ArduinoJSON related memory fragmentation
* Changed console logging using less memory
* Add GPIO04 as user selectable for Sonoff Dual (#75)
2017-02-17 17:18:41 +01:00