* Add new webcam driver over latest dev. To use the old one, define USE_WEBCAM_LAGACY
* enable build without RTSP.
check pin_pwdn before using it n 0x105!!!
* more fixes around pwdn. Make wcresolution -1 set the resoltuion setting to 'disbale cam' value (15).
* fix task stop - wait for debug to leave-> prevents guru. pin task to core 0.
* split motion from other code. Add USE_WEBCAM_MOTION to control inclusion of motion code (big hit). Change from using USE_WEBCAM_LEGACY to USE_WEBCAM_V2
* logging minimisation - behind WEBCAM_DEV_DEBUG
* [DS18x20] Enhance use of aliases
`defineDS18x20_USE_ID_AS_NAME`:
Always show part of the address, even for one sensor
`#define DS18x20_USE_ID_ALIAS`:
The command `DS18Alias` can now be use with alphanumeric aliases, which replace the sensor name
* [DS18x20] change to calloc()
* add: update DEBUG_THERMOSTAT to only control the virtual switch
Also, debug output is still generated but end user can control this debug level 3
* add: debug output of main controller parameters when thermostat enabled
Also, add units for debug outputs added to make them more intelligible
* Update xdrv_39_thermostat.ino
* add: debug message when sensor is detected as not alive
fix: display thermostat number in debug messages
* add: log message prefix string for thermostat
* Update xdrv_39_thermostat.ino
fix: typos in comments
add: debug messages
* add: debug prefix for thermostat
* add: debug prefix added to output lines
* fix: comment typos and small grammatical changes for clarity
* add: debug prefix 'THE' added to debug output
* add: display PID status and key info on web output
* fix: remove extraneous comments that included unused code fragments
* add: local sensor handling improvements
add: define a local sensor name
add: define the local sensor measurement parameter
add: limit sensor not seen error message to every 60 seconds to avoid flooding the logs
add: include interval since which sensor data was last updated
fix: properly update the maximum interval time so missing sensor data is properly alerted
* Update xdrv_49_pid.ino
* add: update DEBUG_THERMOSTAT to only control the virtual switch
Also, debug output is still generated but end user can control this debug level 3
* add: debug output of main controller parameters when thermostat enabled
Also, add units for debug outputs added to make them more intelligible
* Update xdrv_39_thermostat.ino
* add: debug message when sensor is detected as not alive
fix: display thermostat number in debug messages
* add: log message prefix string for thermostat
* Update xdrv_39_thermostat.ino
fix: typos in comments
add: debug messages
* add: debug prefix for thermostat
* add: debug prefix added to output lines
* fix: comment typos and small grammatical changes for clarity
* add: debug prefix 'THE' added to debug output
* skip stop on hold if grouptopic
If shutterbutton is defined with a grouptopic send on HOLD, there is no stop on releasing the button. All shutters will move to defined position
* do not stop on hold release if group submitt
If mqtt broadcast is defined on hold then release the hold button will not anymore stop the local shutter. All shutter will move to defined position
* Restart MAX17043 from the scratch
* revert change
* Changed battery capacity in charge (capacity is the Ah value of the battery, this degrades over time when battery ages)
* merge
* Changing xsns_109 to 110
* fix nr
* removed old xsns109
* Update I2CDEVICES.md
* clean-up usage of Interface
* New LWT on deepsleep
To allow better integration into HA LWT topic will report details of sleep status:
16:54:04.388 MQT: hm/tele/ESP_3284D1/LWT =
{"Sleep":{"Time":"2023-07-17T16:55:03","Sleep":1689612844,"Wakeup":1689612903}}
* Revert LWT back to non JSON
Send DeelSleep on LWT
Send Deepsleep parameters on topic DeepSleep
* Setting default for batteryLevel
* Enable BatteryPercentSet
Changing the battery level e.g. by rule
* Added Battery % to status message
* added battery_level_percent
* Added battery % support in STATE message
* Enable setting battery level
101 is reserved for power-plug. No battery Level reported
* Setting default for battery Level
101 is reserved for power plug
0..100 normal battery values
* Revert back LWT to Offline
Removed "DeepSleep" LWT status until further decision is made. Current implementation is technical sufficient for HA to detect a battery powered device
* Added discovery message after deepsleep change
* Added discovery for battery and deepsleep
Changing default for DisplayMode from 1 to 0. Users are getting confused by the display doing something they did not ask for (and not being aware of DisplayMode). This got worse with LVGL/HASPmota displays becoming common, with users having much less reason to dive into the old DisplayXxxxx commands. And it may even be hard to see that it is even a display of time/date causing the display to flicker.
Changing default for DisplayDimmer from 10% to 50%. The low brightness of 10% is not always easy to see, especially in daylight. 50% is generally better, while not going "full blast" with 100%.
* Remove recursion into folders on Manage Files. May be enabled with UFILESYS_RECURSEFOLDERS_GUI. On Edit of a file, Save and Magane btuttons return to the folder containgint the file being edited. On delete file, UI returns to the folder that the deleted file was in.
* Make newfile put in in the current folder, and return to current folder on save of manage button.
* Add folderOnly and FileOnly functions to reduce code duplication.
Enable folder delete.
Enable folder listing to be aborted (x in browser)
Disbale ESP32 Download Task. Needs attention.
Allow folder create from newfile name.
This change will allow mqtt messages simpler by allowing something like
`publish cmnd/ir-bridge/IRHVAC {"Power": "On"}`.
The simpler format is required for working with mqtt clients like
iotMQTTPanel or similar on android.
Limitations:
- Requires full message be sent at-least once. I work around this with
a `system#boot` rule
- Gets messy with multiple devices. I have only one AC per room, and
this doesn't doesn't interfere with other IR devices.
TODO:
- [ ] Change the build flag `INCREMENTAL_IRAC`to a `SetOption`
- [ ] Persist `irac_prev_state` across reboots.
- [ ] Support multiple devices.
This reduces allocation to a single allocaiton, but also theroetically allows the Bytes object to grow if content-length was unset.
(cherry picked from commit 936477f5977dd1a4f899498cc7cc0baf05b34a89)
* remove unused variable
* Relocate SO92 implementation
This way, SO92 does not ignore SO106
* Relocate RGBWWTable implementation
This fixes a bug related to RGBWWTable and SO92.
Also, the code is tidier this way
* Cleanup: Reduce code duplication
* more consistent behaviour for SO92 and free_cw
---------
Co-authored-by: jonschz <jonschz@users.noreply.github.com>
* Add mutex to many camera functions.
* Allow stream to continue after wcinit command (and other commands which reconfigure).
* Adust retries on camera init, specifically log success if it retried.
Shorten messages to save rom.
I have seen fail of 0x103 and 0x20002 succeed on second try.
* IR: Added support for new A/C protocol fields
New fields introduced in IRremoteESP8266 v2.8.5:
1. Command (one of: [Control | Config | iFeel | Timer], default: Control) - allows to set IR command type (e.g. iFeel for no-beep ambient sensor report)
2. iFeel (boolean, default: false) - configures whether iFeel (ambient sensor temp. is used by the A/C unit)
3. SensorTemp - the ambient sensor temperature reading to send
Note:
- Fan setting via int is now 6-value (breaking change -> 6 is the new max)
* IR A/C: Model now pretty-printed to JSON
Model string is the default (falls back to int if n/a)
* IR A/C: Added separate JSON resp. per command type
* No change for "kControlCommand" (default/legacy).
* SensorReport/Timer/Config commands only contain relevant JSON nodes
Additionally:
Clock has time semantics (input: minutes, output: HH:MM), except for "config" mode,
where state.clock is used as ConfigKey and state.sleep is used as ConfigValue.
---------
Co-authored-by: Mateusz Bronk <2566147+mbronk@users.noreply.github.com>