xdrv_11_knx.ino - KNX IP Protocol support for Sonoff-Tasmota
|
|
|
|
Copyright (C) 2018 Adrian Scillato (https://github.com/ascillato)
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
#ifdef USE_KNX
|
|
/*********************************************************************************************\
|
|
* KNX support
|
|
*
|
|
* Using libraries:
|
|
* ESP KNX IP library (https://github.com/envy/esp-knx-ip)
|
|
|
|
Constants in sonoff.h
|
|
-----------------------
|
|
|
|
#define MAX_KNX_GA 10 Max number of KNX Group Addresses to read that can be set
|
|
#define MAX_KNX_CB 10 Max number of KNX Group Addresses to write that can be set
|
|
If you change MAX_KNX_CB you also have to change on the esp-knx-ip.h file the following:
|
|
#define MAX_CALLBACK_ASSIGNMENTS 10
|
|
#define MAX_CALLBACKS 10
|
|
Both to MAX_KNX_CB
|
|
|
|
Variables in settings.h
|
|
-----------------------
|
|
|
|
bool Settings.flag.knx_enabled Enable/Disable KNX Protocol
|
|
uint16_t Settings.knx_physsical_addr Physical KNX address of this device
|
|
byte Settings.knx_GA_registered Number of group address to read
|
|
byte Settings.knx_CB_registered Number of group address to write
|
|
uint16_t Settings.knx_GA_addr[MAX_KNX_GA] Group address to read
|
|
uint16_t Settings.knx_CB_addr[MAX_KNX_CB] Group address to write
|
|
byte Settings.knx_GA_param[MAX_KNX_GA] Type of Input (relay changed, button pressed, sensor read)
|
|
byte Settings.knx_CB_param[MAX_KNX_CB] Type of Output (set relay, toggle relay, reply sensor value)
|
|
|
|
\*********************************************************************************************/
|
|
|
|
#include <esp-knx-ip.h>
|
|
|
|
//void KNX_CB_Action(message_t const &msg, void *arg); // Define function (action callback) to be called by the KNX_IP Library
|
|
// when an action is requested by another KNX Device
|
|
|
|
address_t KNX_physs_addr; // Physical KNX address of this device
|
|
address_t KNX_addr; // KNX Address converter variable
|
|
|
|
#define KNX_Empty 255
|
|
#define KNX_TEMPERATURE 17
|
|
#define KNX_HUMIDITY 18
|
|
#define KNX_MAX_device_param 18
|
|
|
|
float last_temp;
|
|
float last_hum;
|
|
|
|
typedef struct __device_parameters
|
|
{
|
|
byte type; // PARAMETER_ID. Used as type of GA = relay, button, sensor, etc, (INPUTS)
|
|
// used when an action on device triggers a MSG to send on KNX
|
|
// Needed because this is the value that the ESP_KNX_IP library will pass as parameter
|
|
// to identify the action to perform when a MSG is received
|
|
|
|
bool show; // HARDWARE related. to identify if the parameter exists on the device.
|
|
|
|
bool last_state; // LAST_STATE of relays
|
|
|
|
callback_id_t CB_id; // ACTION_ID. To store the ID value of Registered_CB to the library.
|
|
// The ESP_KNX_IP requires to register the callbacks, and then, to assign an address to the registered callback
|
|
// So CB_id is needed to store the ID of the callback to then, assign multiple addresses to the same ID (callback)
|
|
// It is used as type of CB = set relay, toggle relay, reply sensor, etc, (OUTPUTS)
|
|
// used when a MSG receive KNX triggers an action on the device
|
|
// - Multiples address to the same callback (i.e. Set Relay 1 Status) are used on scenes for example
|
|
} device_parameters_t;
|
|
|
|
// device parameters (information that can be sent)
|
|
device_parameters_t device_param[] = {
|
|
{ 1, false, false, KNX_Empty }, // device_param[ 0] = Relay 1
|
|
{ 2, false, false, KNX_Empty }, // device_param[ 1] = Relay 2
|
|
{ 3, false, false, KNX_Empty }, // device_param[ 2] = Relay 3
|
|
{ 4, false, false, KNX_Empty }, // device_param[ 3] = Relay 4
|
|
{ 5, false, false, KNX_Empty }, // device_param[ 4] = Relay 5
|
|
{ 6, false, false, KNX_Empty }, // device_param[ 5] = Relay 6
|
|
{ 7, false, false, KNX_Empty }, // device_param[ 6] = Relay 7
|
|
{ 8, false, false, KNX_Empty }, // device_param[ 7] = Relay 8
|
|
{ 9, false, false, KNX_Empty }, // device_param[ 8] = Button 1
|
|
{ 10, false, false, KNX_Empty }, // device_param[ 9] = Button 2
|
|
{ 11, false, false, KNX_Empty }, // device_param[10] = Button 3
|
|
{ 12, false, false, KNX_Empty }, // device_param[11] = Button 4
|
|
{ 13, false, false, KNX_Empty }, // device_param[12] = Button 5
|
|
{ 14, false, false, KNX_Empty }, // device_param[13] = Button 6
|
|
{ 15, false, false, KNX_Empty }, // device_param[14] = Button 7
|
|
{ 16, false, false, KNX_Empty }, // device_param[15] = Button 8
|
|
{ KNX_TEMPERATURE, false, false, KNX_Empty }, // device_param[16] = Temperature
|
|
{ KNX_HUMIDITY , false, false, KNX_Empty }, // device_param[17] = humidity
|
|
{ KNX_Empty, false, false, KNX_Empty}
|
|
};
|
|
|
|
// device parameters (information that can be sent)
|
|
const char * device_param_ga[] = {
|
|
D_SENSOR_RELAY " 1", // Relay 1
|
|
D_SENSOR_RELAY " 2", // Relay 2
|
|
D_SENSOR_RELAY " 3", // Relay 3
|
|
D_SENSOR_RELAY " 4", // Relay 4
|
|
D_SENSOR_RELAY " 5", // Relay 5
|
|
D_SENSOR_RELAY " 6", // Relay 6
|
|
D_SENSOR_RELAY " 7", // Relay 7
|
|
D_SENSOR_RELAY " 8", // Relay 8
|
|
D_SENSOR_BUTTON " 1", // Button 1
|
|
D_SENSOR_BUTTON " 2", // Button 2
|
|
D_SENSOR_BUTTON " 3", // Button 3
|
|
D_SENSOR_BUTTON " 4", // Button 4
|
|
D_SENSOR_BUTTON " 5", // Button 5
|
|
D_SENSOR_BUTTON " 6", // Button 6
|
|
D_SENSOR_BUTTON " 7", // Button 7
|
|
D_SENSOR_BUTTON " 8", // Button 8
|
|
D_TEMPERATURE , // Temperature
|
|
D_HUMIDITY , // Humidity
|
|
nullptr
|
|
};
|
|
|
|
// device actions (posible actions to be performed on the device)
|
|
const char *device_param_cb[] = {
|
|
D_SENSOR_RELAY " 1", // Set Relay 1 (1-On or 0-OFF)
|
|
D_SENSOR_RELAY " 2",
|
|
D_SENSOR_RELAY " 3",
|
|
D_SENSOR_RELAY " 4",
|
|
D_SENSOR_RELAY " 5",
|
|
D_SENSOR_RELAY " 6",
|
|
D_SENSOR_RELAY " 7",
|
|
D_SENSOR_RELAY " 8",
|
|
D_SENSOR_RELAY " 1 " D_BUTTON_TOGGLE, // Relay 1 Toggle (1 or 0 will toggle)
|
|
D_SENSOR_RELAY " 2 " D_BUTTON_TOGGLE,
|
|
D_SENSOR_RELAY " 3 " D_BUTTON_TOGGLE,
|
|
D_SENSOR_RELAY " 4 " D_BUTTON_TOGGLE,
|
|
D_SENSOR_RELAY " 5 " D_BUTTON_TOGGLE,
|
|
D_SENSOR_RELAY " 6 " D_BUTTON_TOGGLE,
|
|
D_SENSOR_RELAY " 7 " D_BUTTON_TOGGLE,
|
|
D_SENSOR_RELAY " 8 " D_BUTTON_TOGGLE,
|
|
D_REPLY " " D_TEMPERATURE, // Reply Temperature
|
|
D_REPLY " " D_HUMIDITY, // Reply Humidity
|
|
nullptr
|
|
};
|
|
|
|
|
|
byte KNX_GA_Search( byte param, byte start = 0 )
|
|
{
|
|
for (byte i = start; i < Settings.knx_GA_registered; ++i)
|
|
{
|
|
if ( Settings.knx_GA_param[i] == param )
|
|
{
|
|
if ( Settings.knx_GA_addr[i] != 0 ) // Relay has group address set? GA=0/0/0 can not be used as KNX address, so it is used here as a: not set value
|
|
{
|
|
if ( i >= start ) { return i; }
|
|
}
|
|
}
|
|
}
|
|
return KNX_Empty;
|
|
}
|
|
|
|
|
|
byte KNX_CB_Search( byte param, byte start = 0 )
|
|
{
|
|
for (byte i = start; i < Settings.knx_CB_registered; ++i)
|
|
{
|
|
if ( Settings.knx_CB_param[i] == param )
|
|
{
|
|
if ( Settings.knx_CB_addr[i] != 0 )
|
|
{
|
|
if ( i >= start ) { return i; }
|
|
}
|
|
}
|
|
}
|
|
return KNX_Empty;
|
|
}
|
|
|
|
|
|
void KNX_ADD_GA( byte GAop, byte GA_FNUM, byte GA_AREA, byte GA_FDEF )
|
|
{
|
|
// Check if all GA were assigned. If yes-> return
|
|
if ( Settings.knx_GA_registered >= MAX_KNX_GA ) { return; }
|
|
if ( GA_FNUM == 0 && GA_AREA == 0 && GA_FDEF == 0 ) { return; }
|
|
|
|
// Assign a GA to that address
|
|
Settings.knx_GA_param[Settings.knx_GA_registered] = GAop;
|
|
KNX_addr.ga.area = GA_FNUM;
|
|
KNX_addr.ga.line = GA_AREA;
|
|
KNX_addr.ga.member = GA_FDEF;
|
|
Settings.knx_GA_addr[Settings.knx_GA_registered] = KNX_addr.value;
|
|
|
|
Settings.knx_GA_registered++;
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_ADD " GA #%d: %s " D_TO " %d/%d/%d"),
|
|
Settings.knx_GA_registered,
|
|
device_param_ga[GAop-1],
|
|
GA_FNUM, GA_AREA, GA_FDEF );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
}
|
|
|
|
|
|
void KNX_DEL_GA( byte GAnum )
|
|
{
|
|
|
|
byte dest_offset = 0;
|
|
byte src_offset = 0;
|
|
byte len = 0;
|
|
|
|
// Delete GA
|
|
Settings.knx_GA_param[GAnum-1] = 0;
|
|
|
|
if (GAnum == 1)
|
|
{
|
|
// start of array, so delete first entry
|
|
src_offset = 1;
|
|
// Settings.knx_GA_registered will be 1 in case of only one entry
|
|
// Settings.knx_GA_registered will be 2 in case of two entries, etc..
|
|
// so only copy anything, if there is it at least more then one element
|
|
len = (Settings.knx_GA_registered - 1);
|
|
}
|
|
else if (GAnum == Settings.knx_GA_registered)
|
|
{
|
|
// last element, don't do anything, simply decrement counter
|
|
}
|
|
else
|
|
{
|
|
// somewhere in the middle
|
|
// need to calc offsets
|
|
|
|
// skip all prev elements
|
|
dest_offset = GAnum -1 ; // GAnum -1 is equal to how many element are in front of it
|
|
src_offset = dest_offset + 1; // start after the current element
|
|
len = (Settings.knx_GA_registered - GAnum);
|
|
}
|
|
|
|
if (len > 0)
|
|
{
|
|
memmove(Settings.knx_GA_param + dest_offset, Settings.knx_GA_param + src_offset, len * sizeof(byte));
|
|
memmove(Settings.knx_GA_addr + dest_offset, Settings.knx_GA_addr + src_offset, len * sizeof(uint16_t));
|
|
}
|
|
|
|
Settings.knx_GA_registered--;
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_DELETE " GA #%d"),
|
|
GAnum );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
}
|
|
|
|
|
|
void KNX_ADD_CB( byte CBop, byte CB_FNUM, byte CB_AREA, byte CB_FDEF )
|
|
{
|
|
// Check if all callbacks were assigned. If yes-> return
|
|
if ( Settings.knx_CB_registered >= MAX_KNX_CB ) { return; }
|
|
if ( CB_FNUM == 0 && CB_AREA == 0 && CB_FDEF == 0 ) { return; }
|
|
|
|
// Check if a CB for CBop was registered on the ESP-KNX-IP Library
|
|
if ( device_param[CBop-1].CB_id == KNX_Empty )
|
|
{
|
|
// if no, register the CB for CBop
|
|
device_param[CBop-1].CB_id = knx.callback_register("", KNX_CB_Action, &device_param[CBop-1]);
|
|
// KNX IP Library requires a parameter
|
|
// to identify which action was requested on the KNX network
|
|
// to be performed on this device (set relay, etc.)
|
|
// Is going to be used device_param[j].type that stores the type number (1: relay 1, etc)
|
|
}
|
|
// Assign a callback to CB address
|
|
Settings.knx_CB_param[Settings.knx_CB_registered] = CBop;
|
|
KNX_addr.ga.area = CB_FNUM;
|
|
KNX_addr.ga.line = CB_AREA;
|
|
KNX_addr.ga.member = CB_FDEF;
|
|
Settings.knx_CB_addr[Settings.knx_CB_registered] = KNX_addr.value;
|
|
|
|
knx.callback_assign( device_param[CBop-1].CB_id, KNX_addr );
|
|
|
|
Settings.knx_CB_registered++;
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_ADD " CB #%d: %d/%d/%d " D_TO " %s"),
|
|
Settings.knx_CB_registered,
|
|
CB_FNUM, CB_AREA, CB_FDEF,
|
|
device_param_cb[CBop-1] );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
}
|
|
|
|
|
|
void KNX_DEL_CB( byte CBnum )
|
|
{
|
|
byte oldparam = Settings.knx_CB_param[CBnum-1];
|
|
byte dest_offset = 0;
|
|
byte src_offset = 0;
|
|
byte len = 0;
|
|
|
|
// Delete assigment
|
|
knx.callback_unassign(CBnum-1);
|
|
Settings.knx_CB_param[CBnum-1] = 0;
|
|
|
|
if (CBnum == 1)
|
|
{
|
|
// start of array, so delete first entry
|
|
src_offset = 1;
|
|
// Settings.knx_CB_registered will be 1 in case of only one entry
|
|
// Settings.knx_CB_registered will be 2 in case of two entries, etc..
|
|
// so only copy anything, if there is it at least more then one element
|
|
len = (Settings.knx_CB_registered - 1);
|
|
}
|
|
else if (CBnum == Settings.knx_CB_registered)
|
|
{
|
|
// last element, don't do anything, simply decrement counter
|
|
}
|
|
else
|
|
{
|
|
// somewhere in the middle
|
|
// need to calc offsets
|
|
|
|
// skip all prev elements
|
|
dest_offset = CBnum -1 ; // GAnum -1 is equal to how many element are in front of it
|
|
src_offset = dest_offset + 1; // start after the current element
|
|
len = (Settings.knx_CB_registered - CBnum);
|
|
}
|
|
|
|
if (len > 0)
|
|
{
|
|
memmove(Settings.knx_CB_param + dest_offset, Settings.knx_CB_param + src_offset, len * sizeof(byte));
|
|
memmove(Settings.knx_CB_addr + dest_offset, Settings.knx_CB_addr + src_offset, len * sizeof(uint16_t));
|
|
}
|
|
|
|
Settings.knx_CB_registered--;
|
|
|
|
// Check if there is no other assigment to that callback. If there is not. delete that callback register
|
|
if ( KNX_CB_Search( oldparam ) == KNX_Empty ) {
|
|
knx.callback_deregister( device_param[oldparam-1].CB_id );
|
|
device_param[oldparam-1].CB_id = KNX_Empty;
|
|
}
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_DELETE " CB #%d"), CBnum );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
}
|
|
|
|
|
|
bool KNX_CONFIG_NOT_MATCH()
|
|
{
|
|
for (int i = 0; i < KNX_MAX_device_param; ++i)
|
|
{
|
|
if ( !device_param[i].show ) { // device has this parameter ?
|
|
// if not, search for all registered group address to this parameter for deletion
|
|
if ( KNX_GA_Search(i+1) != KNX_Empty ) { return true; }
|
|
if ( (i < 8) || (i > 15) ) // check relays and sensors (i from 8 to 16 are toggle relays parameters)
|
|
{
|
|
if ( KNX_CB_Search(i+1) != KNX_Empty ) { return true; }
|
|
if ( KNX_CB_Search(i+8) != KNX_Empty ) { return true; }
|
|
}
|
|
}
|
|
}
|
|
return false;
|
|
}
|
|
|
|
|
|
void KNXStart()
|
|
{
|
|
knx.start(nullptr);
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_START));
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
}
|
|
|
|
|
|
void KNX_INIT()
|
|
{
|
|
// Check for incompatible config
|
|
if (Settings.knx_GA_registered > MAX_KNX_GA) { Settings.knx_GA_registered = MAX_KNX_GA; }
|
|
if (Settings.knx_CB_registered > MAX_KNX_CB) { Settings.knx_CB_registered = MAX_KNX_CB; }
|
|
|
|
// Set Physical KNX Address of the device
|
|
KNX_physs_addr.value = Settings.knx_physsical_addr;
|
|
knx.physical_address_set( KNX_physs_addr );
|
|
|
|
// Read Configuration
|
|
// Check which relays, buttons and sensors where configured for this device
|
|
// and activate options according to the hardware
|
|
for (int i = GPIO_REL1; i < GPIO_REL8 + 1; ++i)
|
|
{
|
|
if (GetUsedInModule(i, my_module.gp.io)) { device_param[i - GPIO_REL1].show = true; }
|
|
}
|
|
for (int i = GPIO_REL1_INV; i < GPIO_REL8_INV + 1; ++i)
|
|
{
|
|
if (GetUsedInModule(i, my_module.gp.io)) { device_param[i - GPIO_REL1_INV].show = true; }
|
|
}
|
|
for (int i = GPIO_SWT1; i < GPIO_SWT4 + 1; ++i)
|
|
{
|
|
if (GetUsedInModule(i, my_module.gp.io)) { device_param[i - GPIO_SWT1 + 8].show = true; }
|
|
}
|
|
for (int i = GPIO_KEY1; i < GPIO_KEY4 + 1; ++i)
|
|
{
|
|
if (GetUsedInModule(i, my_module.gp.io)) { device_param[i - GPIO_KEY1 + 8].show = true; }
|
|
}
|
|
if (GetUsedInModule(GPIO_DHT11, my_module.gp.io)) { device_param[KNX_TEMPERATURE-1].show = true; }
|
|
if (GetUsedInModule(GPIO_DHT22, my_module.gp.io)) { device_param[KNX_TEMPERATURE-1].show = true; }
|
|
if (GetUsedInModule(GPIO_SI7021, my_module.gp.io)) { device_param[KNX_TEMPERATURE-1].show = true; }
|
|
if (GetUsedInModule(GPIO_DHT11, my_module.gp.io)) { device_param[KNX_HUMIDITY-1].show = true; }
|
|
if (GetUsedInModule(GPIO_DHT22, my_module.gp.io)) { device_param[KNX_HUMIDITY-1].show = true; }
|
|
if (GetUsedInModule(GPIO_SI7021, my_module.gp.io)) { device_param[KNX_HUMIDITY-1].show = true; }
|
|
|
|
// Delete from KNX settings all configuration is not anymore related to this device
|
|
if (KNX_CONFIG_NOT_MATCH()) {
|
|
Settings.knx_GA_registered = 0;
|
|
Settings.knx_CB_registered = 0;
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_DELETE " " D_KNX_PARAMETERS ));
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
}
|
|
|
|
// Register Group Addresses to listen to
|
|
// Search on the settings if there is a group address set for receive KNX messages for the type: device_param[j].type
|
|
// If there is, register the group address on the KNX_IP Library to Receive data for Executing Callbacks
|
|
byte j;
|
|
for (byte i = 0; i < Settings.knx_CB_registered; ++i)
|
|
{
|
|
j = Settings.knx_CB_param[i];
|
|
if ( j > 0 )
|
|
{
|
|
device_param[j-1].CB_id = knx.callback_register("", KNX_CB_Action, &device_param[j-1]); // KNX IP Library requires a parameter
|
|
// to identify which action was requested on the KNX network
|
|
// to be performed on this device (set relay, etc.)
|
|
// Is going to be used device_param[j].type that stores the type number (1: relay 1, etc)
|
|
KNX_addr.value = Settings.knx_CB_addr[i];
|
|
knx.callback_assign( device_param[j-1].CB_id, KNX_addr );
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
void KNX_CB_Action(message_t const &msg, void *arg)
|
|
{
|
|
device_parameters_t *chan = (device_parameters_t *)arg;
|
|
|
|
if (!(Settings.flag.knx_enabled)) { return; }
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_RECEIVED_FROM " %d.%d.%d " D_COMMAND " %s: %d " D_TO " %s"),
|
|
msg.received_on.ga.area, msg.received_on.ga.line, msg.received_on.ga.member,
|
|
(msg.ct == KNX_CT_WRITE) ? D_KNX_COMMAND_WRITE : (msg.ct == KNX_CT_READ) ? D_KNX_COMMAND_READ : D_KNX_COMMAND_OTHER,
|
|
msg.data[0],
|
|
device_param_cb[(chan->type)-1]);
|
|
AddLog(LOG_LEVEL_INFO);
|
|
|
|
switch (msg.ct)
|
|
{
|
|
case KNX_CT_WRITE:
|
|
if (chan->type < 9) // Set Relays
|
|
{
|
|
ExecuteCommandPower(chan->type, msg.data[0]);
|
|
}
|
|
else if (chan->type < 17) // Toggle Relays
|
|
{
|
|
ExecuteCommandPower((chan->type) -8, 2);
|
|
}
|
|
break;
|
|
case KNX_CT_READ:
|
|
if (chan->type < 9) // reply Relays status
|
|
{
|
|
knx.answer_1bit(msg.received_on, chan->last_state);
|
|
}
|
|
else if (chan->type = KNX_TEMPERATURE) // Reply Temperature
|
|
{
|
|
knx.answer_2byte_float(msg.received_on, last_temp);
|
|
}
|
|
else if (chan->type = KNX_HUMIDITY) // Reply Humidity
|
|
{
|
|
knx.answer_2byte_float(msg.received_on, last_hum);
|
|
}
|
|
break;
|
|
}
|
|
}
|
|
|
|
|
|
void KnxUpdatePowerState(byte device, power_t state)
|
|
{
|
|
if (!(Settings.flag.knx_enabled)) { return; }
|
|
|
|
device_param[device -1].last_state = bitRead(state, device -1); // power state (on/off)
|
|
|
|
// Search all the registered GA that has that output (variable: device) as parameter
|
|
byte i = KNX_GA_Search(device);
|
|
while ( i != KNX_Empty ) {
|
|
KNX_addr.value = Settings.knx_GA_addr[i];
|
|
knx.write_1bit(KNX_addr, device_param[device -1].last_state);
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX "%s = %d " D_SENT_TO " %d.%d.%d"),
|
|
device_param_ga[device -1], device_param[device -1].last_state,
|
|
KNX_addr.ga.area, KNX_addr.ga.line, KNX_addr.ga.member);
|
|
AddLog(LOG_LEVEL_INFO);
|
|
|
|
i = KNX_GA_Search(device, i + 1);
|
|
}
|
|
}
|
|
|
|
|
|
void KnxSendButtonPower(byte key, byte device, byte state)
|
|
{
|
|
// key 0 = button_topic
|
|
// key 1 = switch_topic
|
|
// state 0 = off
|
|
// state 1 = on
|
|
// state 2 = toggle
|
|
// state 3 = hold
|
|
// state 9 = clear retain flag
|
|
if (!(Settings.flag.knx_enabled)) { return; }
|
|
// if (key)
|
|
// {
|
|
|
|
// Search all the registered GA that has that output (variable: device) as parameter
|
|
byte i = KNX_GA_Search(device + 8);
|
|
while ( i != KNX_Empty ) {
|
|
KNX_addr.value = Settings.knx_GA_addr[i];
|
|
knx.write_1bit(KNX_addr, !(state == 0));
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX "%s = %d " D_SENT_TO " %d.%d.%d"),
|
|
device_param_ga[device + 8], !(state == 0),
|
|
KNX_addr.ga.area, KNX_addr.ga.line, KNX_addr.ga.member);
|
|
AddLog(LOG_LEVEL_INFO);
|
|
|
|
i = KNX_GA_Search(device + 8, i + 1);
|
|
}
|
|
// }
|
|
}
|
|
|
|
|
|
void KnxSensor(byte sensor_type, float value)
|
|
{
|
|
if (sensor_type == KNX_TEMPERATURE)
|
|
{
|
|
last_temp = value;
|
|
} else if (sensor_type == KNX_HUMIDITY)
|
|
{
|
|
last_hum = value;
|
|
}
|
|
|
|
if (!(Settings.flag.knx_enabled)) { return; }
|
|
|
|
byte i = KNX_GA_Search(sensor_type);
|
|
while ( i != KNX_Empty ) {
|
|
KNX_addr.value = Settings.knx_GA_addr[i];
|
|
knx.write_2byte_float(KNX_addr, value);
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX "%s " D_SENT_TO " %d.%d.%d "),
|
|
device_param_ga[sensor_type -1],
|
|
KNX_addr.ga.area, KNX_addr.ga.line, KNX_addr.ga.member);
|
|
AddLog(LOG_LEVEL_INFO);
|
|
|
|
i = KNX_GA_Search(sensor_type, i+1);
|
|
}
|
|
}
|
|
|
|
|
|
/*********************************************************************************************\
|
|
* Presentation
|
|
\*********************************************************************************************/
|
|
|
|
#ifdef USE_WEBSERVER
|
|
const char S_CONFIGURE_KNX[] PROGMEM = D_CONFIGURE_KNX;
|
|
|
|
const char HTTP_FORM_KNX[] PROGMEM =
|
|
"<fieldset><legend style='text-align:left;'><b> " D_KNX_PARAMETERS " </b></legend><form method='post' action='kn'>"
|
|
"<br/><center>"
|
|
"<b>" D_KNX_PHYSICAL_ADDRESS " </b>"
|
|
"<input style='width:12%;' type='number' name='area' min='0' max='15' value='{kna'> . "
|
|
"<input style='width:12%;' type='number' name='line' min='0' max='15' value='{knl'> . "
|
|
"<input style='width:12%;' type='number' name='member' min='0' max='255' value='{knm'>"
|
|
"<br/><br/>" D_KNX_PHYSICAL_ADDRESS_NOTE "<br/><br/>"
|
|
"<input style='width:10%;' id='b1' name='b1' type='checkbox'";
|
|
|
|
const char HTTP_FORM_KNX2[] PROGMEM =
|
|
"><b>" D_KNX_ENABLE "</b><br/></center><br/>"
|
|
|
|
"<fieldset><center>"
|
|
"<b>" D_KNX_GROUP_ADDRESS_TO_WRITE "</b><hr>"
|
|
|
|
"<select name='GAop' style='width:25%;'>";
|
|
|
|
const char HTTP_FORM_KNX_OPT[] PROGMEM =
|
|
"<option value='{vop}'>{nop}</option>";
|
|
|
|
const char HTTP_FORM_KNX_GA[] PROGMEM =
|
|
"<input style='width:12%;' type='number' id='GAfnum' name='GAfnum' min='0' max='31' value='0'> / "
|
|
"<input style='width:12%;' type='number' id='GAarea' name='GAarea' min='0' max='7' value='0'> / "
|
|
"<input style='width:12%;' type='number' id='GAfdef' name='GAfdef' min='0' max='255' value='0'> ";
|
|
|
|
const char HTTP_FORM_KNX_ADD_BTN[] PROGMEM =
|
|
"<button type='submit' onclick='fncbtnadd()' btndis name='btn_add' value='{btnval}' style='width:18%;'>" D_ADD "</button><br/><br/>"
|
|
"<table style='width:80%; font-size: 14px;'><col width='250'><col width='30'>";
|
|
|
|
const char HTTP_FORM_KNX_ADD_TABLE_ROW[] PROGMEM =
|
|
"<tr><td><b>{optex} -> GAfnum / GAarea / GAfdef </b></td>"
|
|
// "<td><button type='submit' name='btn_del_ga' value='{opval}' style='background-color: #eb1e1e;'> " D_DELETE " </button></td></tr>";
|
|
"<td><button type='submit' name='btn_del_ga' value='{opval}' class='button bred'> " D_DELETE " </button></td></tr>";
|
|
|
|
const char HTTP_FORM_KNX3[] PROGMEM =
|
|
"</table></center></fieldset><br/>"
|
|
"<fieldset><form method='post' action='kn'><center>"
|
|
"<b>" D_KNX_GROUP_ADDRESS_TO_READ "</b><hr>";
|
|
|
|
const char HTTP_FORM_KNX4[] PROGMEM =
|
|
"-> <select name='CBop' style='width:25%;'>";
|
|
|
|
const char HTTP_FORM_KNX_ADD_TABLE_ROW2[] PROGMEM =
|
|
"<tr><td><b>GAfnum / GAarea / GAfdef -> {optex}</b></td>"
|
|
// "<td><button type='submit' name='btn_del_cb' value='{opval}' style='background-color: #eb1e1e;'> " D_DELETE " </button></td></tr>";
|
|
"<td><button type='submit' name='btn_del_cb' value='{opval}' class='button bred'> " D_DELETE " </button></td></tr>";
|
|
|
|
|
|
void HandleKNXConfiguration()
|
|
{
|
|
char tmp[100];
|
|
String stmp;
|
|
|
|
if (HTTP_USER == webserver_state) {
|
|
HandleRoot();
|
|
return;
|
|
}
|
|
AddLog_P(LOG_LEVEL_DEBUG, S_LOG_HTTP, S_CONFIGURE_KNX);
|
|
|
|
if ( WebServer->hasArg("save") ) {
|
|
KNX_Save_Settings();
|
|
HandleConfiguration();
|
|
}
|
|
else
|
|
{
|
|
if ( WebServer->hasArg("btn_add") ) {
|
|
if ( WebServer->arg("btn_add") == "1" ) {
|
|
|
|
stmp = WebServer->arg("GAop"); //option selected
|
|
byte GAop = stmp.toInt();
|
|
stmp = WebServer->arg("GA_FNUM");
|
|
byte GA_FNUM = stmp.toInt();
|
|
stmp = WebServer->arg("GA_AREA");
|
|
byte GA_AREA = stmp.toInt();
|
|
stmp = WebServer->arg("GA_FDEF");
|
|
byte GA_FDEF = stmp.toInt();
|
|
|
|
KNX_ADD_GA( GAop, GA_FNUM, GA_AREA, GA_FDEF );
|
|
|
|
}
|
|
else
|
|
{
|
|
|
|
stmp = WebServer->arg("CBop"); //option selected
|
|
byte CBop = stmp.toInt();
|
|
stmp = WebServer->arg("CB_FNUM");
|
|
byte CB_FNUM = stmp.toInt();
|
|
stmp = WebServer->arg("CB_AREA");
|
|
byte CB_AREA = stmp.toInt();
|
|
stmp = WebServer->arg("CB_FDEF");
|
|
byte CB_FDEF = stmp.toInt();
|
|
|
|
KNX_ADD_CB( CBop, CB_FNUM, CB_AREA, CB_FDEF );
|
|
|
|
}
|
|
}
|
|
else if ( WebServer->hasArg("btn_del_ga") )
|
|
{
|
|
|
|
stmp = WebServer->arg("btn_del_ga");
|
|
byte GA_NUM = stmp.toInt();
|
|
|
|
KNX_DEL_GA(GA_NUM);
|
|
|
|
}
|
|
else if ( WebServer->hasArg("btn_del_cb") )
|
|
{
|
|
|
|
stmp = WebServer->arg("btn_del_cb");
|
|
byte CB_NUM = stmp.toInt();
|
|
|
|
KNX_DEL_CB(CB_NUM);
|
|
|
|
}
|
|
|
|
String page = FPSTR(HTTP_HEAD);
|
|
page.replace(F("{v}"), FPSTR(S_CONFIGURE_KNX));
|
|
page += FPSTR(HTTP_HEAD_STYLE);
|
|
page.replace(F("340px"), F("530px"));
|
|
page += FPSTR(HTTP_FORM_KNX);
|
|
KNX_physs_addr.value = Settings.knx_physsical_addr;
|
|
page.replace(F("{kna"), String(KNX_physs_addr.pa.area));
|
|
page.replace(F("{knl"), String(KNX_physs_addr.pa.line));
|
|
page.replace(F("{knm"), String(KNX_physs_addr.pa.member));
|
|
if ( Settings.flag.knx_enabled ) { page += F(" checked"); }
|
|
|
|
page += FPSTR(HTTP_FORM_KNX2);
|
|
for (byte i = 0; i < KNX_MAX_device_param ; i++)
|
|
{
|
|
if ( device_param[i].show )
|
|
{
|
|
page += FPSTR(HTTP_FORM_KNX_OPT);
|
|
page.replace(F("{vop}"), String(device_param[i].type));
|
|
page.replace(F("{nop}"), String(device_param_ga[i]));
|
|
}
|
|
}
|
|
page += F("</select> -> ");
|
|
page += FPSTR(HTTP_FORM_KNX_GA);
|
|
page.replace(F("GAfnum"), F("GA_FNUM"));
|
|
page.replace(F("GAarea"), F("GA_AREA"));
|
|
page.replace(F("GAfdef"), F("GA_FDEF"));
|
|
page.replace(F("GAfnum"), F("GA_FNUM"));
|
|
page.replace(F("GAarea"), F("GA_AREA"));
|
|
page.replace(F("GAfdef"), F("GA_FDEF"));
|
|
page += FPSTR(HTTP_FORM_KNX_ADD_BTN);
|
|
page.replace(F("{btnval}"), String(1));
|
|
if (Settings.knx_GA_registered < MAX_KNX_GA) {
|
|
page.replace(F("btndis"), F(" "));
|
|
}
|
|
else
|
|
{
|
|
page.replace(F("btndis"), F("disabled"));
|
|
}
|
|
page.replace(F("fncbtnadd"), F("GAwarning"));
|
|
for (byte i = 0; i < Settings.knx_GA_registered ; ++i)
|
|
{
|
|
if ( Settings.knx_GA_param[i] )
|
|
{
|
|
page += FPSTR(HTTP_FORM_KNX_ADD_TABLE_ROW);
|
|
page.replace(F("{opval}"), String(i+1));
|
|
page.replace(F("{optex}"), String(device_param_ga[Settings.knx_GA_param[i]-1]));
|
|
KNX_addr.value = Settings.knx_GA_addr[i];
|
|
page.replace(F("GAfnum"), String(KNX_addr.ga.area));
|
|
page.replace(F("GAarea"), String(KNX_addr.ga.line));
|
|
page.replace(F("GAfdef"), String(KNX_addr.ga.member));
|
|
}
|
|
}
|
|
page += FPSTR(HTTP_FORM_KNX3);
|
|
page += FPSTR(HTTP_FORM_KNX_GA);
|
|
page.replace(F("GAfnum"), F("CB_FNUM"));
|
|
page.replace(F("GAarea"), F("CB_AREA"));
|
|
page.replace(F("GAfdef"), F("CB_FDEF"));
|
|
page.replace(F("GAfnum"), F("CB_FNUM"));
|
|
page.replace(F("GAarea"), F("CB_AREA"));
|
|
page.replace(F("GAfdef"), F("CB_FDEF"));
|
|
page += FPSTR(HTTP_FORM_KNX4);
|
|
byte j;
|
|
for (byte i = 0; i < KNX_MAX_device_param ; i++)
|
|
{
|
|
// Check How many Relays are available and add: RelayX and TogleRelayX
|
|
if ( (i > 8) && (i < 16) ) { j=i-8; } else { j=i; }
|
|
if ( i == 8 ) { j = 0; }
|
|
if ( device_param[j].show )
|
|
{
|
|
page += FPSTR(HTTP_FORM_KNX_OPT);
|
|
page.replace(F("{vop}"), String(device_param[i].type));
|
|
page.replace(F("{nop}"), String(device_param_cb[i]));
|
|
}
|
|
}
|
|
page += F("</select> ");
|
|
page += FPSTR(HTTP_FORM_KNX_ADD_BTN);
|
|
page.replace(F("{btnval}"), String(2));
|
|
if (Settings.knx_CB_registered < MAX_KNX_CB) {
|
|
page.replace(F("btndis"), F(" "));
|
|
}
|
|
else
|
|
{
|
|
page.replace(F("btndis"), F("disabled"));
|
|
}
|
|
page.replace(F("fncbtnadd"), F("CBwarning"));
|
|
for (byte i = 0; i < Settings.knx_CB_registered ; ++i)
|
|
{
|
|
if ( Settings.knx_CB_param[i] )
|
|
{
|
|
page += FPSTR(HTTP_FORM_KNX_ADD_TABLE_ROW2);
|
|
page.replace(F("{opval}"), String(i+1));
|
|
page.replace(F("{optex}"), String(device_param_cb[Settings.knx_CB_param[i]-1]));
|
|
KNX_addr.value = Settings.knx_CB_addr[i];
|
|
page.replace(F("GAfnum"), String(KNX_addr.ga.area));
|
|
page.replace(F("GAarea"), String(KNX_addr.ga.line));
|
|
page.replace(F("GAfdef"), String(KNX_addr.ga.member));
|
|
}
|
|
}
|
|
page += F("</table></center></fieldset>");
|
|
page += F("<br/><button name='save' type='submit'>" D_SAVE "</button></form></fieldset>");
|
|
page += FPSTR(HTTP_BTN_CONF);
|
|
|
|
page.replace( F("</script>"),
|
|
F("function GAwarning()"
|
|
"{"
|
|
"var GA_FNUM = document.getElementById('GA_FNUM');"
|
|
"var GA_AREA = document.getElementById('GA_AREA');"
|
|
"var GA_FDEF = document.getElementById('GA_FDEF');"
|
|
"if ( GA_FNUM != null && GA_FNUM.value == '0' && GA_AREA.value == '0' && GA_FDEF.value == '0' ) {"
|
|
"alert('" D_KNX_WARNING "');"
|
|
"}"
|
|
"}"
|
|
"function CBwarning()"
|
|
"{"
|
|
"var CB_FNUM = document.getElementById('CB_FNUM');"
|
|
"var CB_AREA = document.getElementById('CB_AREA');"
|
|
"var CB_FDEF = document.getElementById('CB_FDEF');"
|
|
"if ( CB_FNUM != null && CB_FNUM.value == '0' && CB_AREA.value == '0' && CB_FDEF.value == '0' ) {"
|
|
"alert('" D_KNX_WARNING "');"
|
|
"}"
|
|
"}"
|
|
"</script>") );
|
|
ShowPage(page);
|
|
}
|
|
|
|
}
|
|
|
|
|
|
void KNX_Save_Settings()
|
|
{
|
|
String stmp;
|
|
address_t KNX_addr;
|
|
byte i;
|
|
|
|
Settings.flag.knx_enabled = WebServer->hasArg("b1");
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_ENABLED ": %d "),
|
|
Settings.flag.knx_enabled);
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
|
|
stmp = WebServer->arg("area");
|
|
KNX_addr.pa.area = stmp.toInt();
|
|
stmp = WebServer->arg("line");
|
|
KNX_addr.pa.line = stmp.toInt();
|
|
stmp = WebServer->arg("member");
|
|
KNX_addr.pa.member = stmp.toInt();
|
|
Settings.knx_physsical_addr = KNX_addr.value;
|
|
knx.physical_address_set( KNX_addr ); // Set Physical KNX Address of the device
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX D_KNX_PHYSICAL_ADDRESS ": %d.%d.%d "),
|
|
KNX_addr.pa.area, KNX_addr.pa.line, KNX_addr.pa.member );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX "GA: %d"),
|
|
Settings.knx_GA_registered );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
for (i = 0; i < Settings.knx_GA_registered ; ++i)
|
|
{
|
|
KNX_addr.value = Settings.knx_GA_addr[i];
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX "GA #%d: %s " D_TO " %d/%d/%d"),
|
|
i+1, device_param_ga[Settings.knx_GA_param[i]-1],
|
|
KNX_addr.ga.area, KNX_addr.ga.line, KNX_addr.ga.member );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
}
|
|
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX "CB: %d"),
|
|
Settings.knx_CB_registered );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
for (i = 0; i < Settings.knx_CB_registered ; ++i)
|
|
{
|
|
KNX_addr.value = Settings.knx_CB_addr[i];
|
|
snprintf_P(log_data, sizeof(log_data), PSTR(D_LOG_KNX "CB #%d: %d/%d/%d " D_TO " %s"),
|
|
i+1,
|
|
KNX_addr.ga.area, KNX_addr.ga.line, KNX_addr.ga.member,
|
|
device_param_cb[Settings.knx_CB_param[i]-1] );
|
|
AddLog(LOG_LEVEL_DEBUG);
|
|
}
|
|
}
|
|
|
|
#endif // USE_WEBSERVER
|
|
|
|
|
|
/*********************************************************************************************\
|
|
* Interface
|
|
\*********************************************************************************************/
|
|
|
|
#define XDRV_11
|
|
|
|
boolean Xdrv11(byte function)
|
|
{
|
|
boolean result = false;
|
|
switch (function) {
|
|
case FUNC_INIT:
|
|
KNX_INIT();
|
|
break;
|
|
case FUNC_LOOP:
|
|
knx.loop(); // Process knx events
|
|
break;
|
|
// case FUNC_COMMAND:
|
|
// result = KNXCommand();
|
|
// break;
|
|
// case FUNC_SET_POWER:
|
|
// break;
|
|
}
|
|
return result;
|
|
}
|
|
|
|
#endif // USE_KNX
|