**Shelly 2 is discontinued and replaced by [Shelly 2.5](shelly-25)**
|
||||||
|
|
||||||
|
The Shelly 2 is fully supported in Tasmota from version 6.2.1.7<br>
|
||||||
|
|
||||||
|
## ⚠️️Special Shelly Attention⚠️️
|
||||||
|
|
||||||
|
**Do not connect AC power and the serial connection at the same time**
|
||||||
|
The GND connection of the Shelly has a 50% chance of being connected to the live AC wire. Connecting serial with your PC will fry your PC.
|
||||||
|
|
||||||
|
**Do not connect any additional sensors to serial pins.**
|
||||||
|
It can at least destroy your Shelly!
|
||||||
|
|
||||||
|
**Check the correct jumper position before connecting AC power to Shelly 1.**
|
||||||
|
If the jumper is set to 12V you will destroy your Shelly!
|
||||||
|
# Shelly 2
|
||||||
|
An ESP8266 with 2MB flash dual relay device with Energy Monitoring the size of round 45mm.<br>
|
||||||
|
<img src="https://github.com/arendst/arendst.github.io/blob/master/media/shelly/shelly2_serial_connection2.jpg" height="250" />
|
||||||
|
|
||||||
|
## Templates as of v6.4.1.17
|
||||||
|
The inbuilt template equals the following:<br>
|
||||||
|
``{"NAME":"Shelly 2","GPIO":[0,135,0,136,21,22,0,0,9,0,10,137,0],"FLAG":0,"BASE":47}``<br>
|
||||||
|
An alternative template without switch pull-up is:<br>
|
||||||
|
``{"NAME":"Shelly 2n","GPIO":[0,135,0,136,21,22,0,0,82,0,83,137,0],"FLAG":0,"BASE":47}``
|