mirror of https://github.com/arendst/Tasmota.git
update calibration info
parent
2c32029e73
commit
324e9ea98d
14
Commands.md
14
Commands.md
|
@ -254,7 +254,7 @@ WebLog | 4 | Show all messages
|
||||||
### Sonoff Pow
|
### Sonoff Pow
|
||||||
```
|
```
|
||||||
Command | Payload | Description
|
Command | Payload | Description
|
||||||
----------------|-------------|----------------------------------------------------
|
----------------|-------------|----------------------------------------------------------
|
||||||
CurrentHigh | | Show current current high threshold value
|
CurrentHigh | | Show current current high threshold value
|
||||||
CurrentHigh | 0 | off | (default) Disable current high threshold
|
CurrentHigh | 0 | off | (default) Disable current high threshold
|
||||||
CurrentHigh | <milliamps> | Set current high threshold value
|
CurrentHigh | <milliamps> | Set current high threshold value
|
||||||
|
@ -262,14 +262,14 @@ CurrentLow | | Show current current low threshold value
|
||||||
CurrentLow | 0 | off | (default) Disable current low threshold
|
CurrentLow | 0 | off | (default) Disable current low threshold
|
||||||
CurrentLow | <milliamps> | Set current low threshold value
|
CurrentLow | <milliamps> | Set current low threshold value
|
||||||
HlwIcal | | Show calibration value for Current
|
HlwIcal | | Show calibration value for Current
|
||||||
HlwIcal | 1 | Set program calibration value for Current
|
HlwIcal | 1 | Set default calibration value for Current to 3500
|
||||||
HlwIcal | <value> | Set user calibration value for Current
|
HlwIcal | <value> | Set user calibration value for Current starting from 2500
|
||||||
HlwPcal | | Show calibration value for Power
|
HlwPcal | | Show calibration value for Power
|
||||||
HlwPcal | 1 | Set program calibration value for Power
|
HlwPcal | 1 | Set default calibration value for Power to 12530
|
||||||
HlwIcal | <value> | Set user calibration value for Power
|
HlwIcal | <value> | Set user calibration value for Power starting from 10000
|
||||||
HlwUcal | | Show calibration value for Voltage
|
HlwUcal | | Show calibration value for Voltage
|
||||||
HlwUcal | 1 | Set program calibration value for Voltage
|
HlwUcal | 1 | Set default calibration value for Voltage to 1950
|
||||||
HlwIcal | <value> | Set user calibration value for Voltage
|
HlwIcal | <value> | Set user calibration value for Voltage starting from 1000
|
||||||
PowerHigh | | Show current power high threshold value
|
PowerHigh | | Show current power high threshold value
|
||||||
PowerHigh | 0 | off | (default) Disable power high threshold
|
PowerHigh | 0 | off | (default) Disable power high threshold
|
||||||
PowerHigh | <watt> | Set power high threshold value
|
PowerHigh | <watt> | Set power high threshold value
|
||||||
|
|
|
@ -11,9 +11,9 @@ I used the following procedure to calibrate.
|
||||||
3. Connect the 60W light bulb
|
3. Connect the 60W light bulb
|
||||||
4. Open a webbrowser to Pow showing the main page and another webbrowser showing the Console
|
4. Open a webbrowser to Pow showing the main page and another webbrowser showing the Console
|
||||||
5. Turn power on and wait a few seconds for the pow to settle on a stable power reading
|
5. Turn power on and wait a few seconds for the pow to settle on a stable power reading
|
||||||
6. Verify the power reading with the power meter or expected 60W and if needed change the power offset value with command ```HLWPcal```
|
6. Verify the power reading with the power meter or expected 60W and if needed change the power offset value with command `HLWPcal` starting from 10000. Default value is 12530
|
||||||
7. Verify the voltage reading with the multimeter and if needed change the voltage offset value with command ```HLWUcal```
|
7. Verify the voltage reading with the multimeter and if needed change the voltage offset value with command `HLWUcal` starting from 1000. Default value is 1950
|
||||||
8. Verify the current reading with the calculated value of P (step 6) / U (step 7) and if needed change the current offset with command ```HLWIcal```
|
8. Verify the current reading with the calculated value of P (step 6) / U (step 7) and if needed change the current offset with command `HLWIcal` starting from 2500. Default value is 3500
|
||||||
|
|
||||||
## Result explanation
|
## Result explanation
|
||||||
The Sonoff Pow can provide Energy, Power, Voltage and Current information in different ways.
|
The Sonoff Pow can provide Energy, Power, Voltage and Current information in different ways.
|
||||||
|
|
Loading…
Reference in New Issue