Updated Tuya Protocols (markdown)

emanuelecavestri 2019-11-20 23:03:31 +01:00
parent 2072d5ef30
commit 5b8113b626
1 changed files with 11 additions and 0 deletions

@ -221,3 +221,14 @@ After receiving a command from Tasmota (Command Word `0x06`), the MCU performs c
| 8 | Holding time setting | keep_warm_setting | Issue and report | Integer | Values range:0-360, Pitch1, Scale0, Unit:min | | 8 | Holding time setting | keep_warm_setting | Issue and report | Integer | Values range:0-360, Pitch1, Scale0, Unit:min |
| 9 | Mode | work_type | Issue and report | Enum | Enumerated values: setting_quick, boiling_quick, temp_setting, temp_ | | 9 | Mode | work_type | Issue and report | Enum | Enumerated values: setting_quick, boiling_quick, temp_setting, temp_ |
``` ```
### BecaThermostat(WIP)
```
| DP ID | Function points | Identifier | Data type | Function type | Properties |
|-------|---------------------|-------------|------------------|---------------|--------------------------------------------|
| 1 | Switch | Power | Issue and report | Boolean | |
| 2 | Target temperature | TempSet | Issue and report | Integer | Values range:0-37, Pitch1, Scale0, Unit:℃ |
| 3 | Current Temperature | TempCurrent | Only report | Integer | Values range:-9-99, Pitch1, Scale0, Unit:℃ |
| 4 | Mode | Mode | Issue and report | Enum | Enumerated values:m, p (wip) |
| 102 | Floor Temperature | FloorCurrent| Issue and report | Integer | Values range:0-37, Pitch1, Scale0, Unit:℃ |
```