Updated Commands (markdown)

Theo Arends 2017-06-19 23:28:12 +02:00
parent a1cdd4fb32
commit 62747ae0e9
1 changed files with 10 additions and 0 deletions

@ -167,6 +167,9 @@ SetOption0 | 0 | off | Do not save power changes and do not set relay afte
SetOption1 | | Show current button multi press mode
SetOption1 | 0 | off | (default) Allow all button actions
SetOption1 | 1 | on | Allow only single, double and hold press button actions
SetOption12 | | Show current configuration flash usage option
SetOption12 | 0 | off | (default) Use dynamic flash to save configuration lowering flash wear
SetOption12 | 1 | on | Legacy save configuration in eeprom flash location only
Sleep | | Show current sleep state as 0 (Off) or duration of up to 250 mSec
Sleep | 0 | off | (default) Turn sleep off
Sleep | 1..250 | Set sleep duration from 1 to 250 mSec to enable energy saving
@ -356,8 +359,13 @@ SetOption10 | 1 | on | When topic changes send old topic retained LWT of
SetOption11 | | Show current button single and double press swap state
SetOption11 | 0 | off | (default) Legacy button single and double press
SetOption11 | 1 | on | Button single and double press functionality swapped
SetOption12 | | Show current configuration flash usage option
SetOption12 | 0 | off | (default) Use dynamic flash to save configuration lowering flash wear
SetOption12 | 1 | on | Legacy save configuration in eeprom flash location only
SetOption32 | | Show current key hold time in 0.1 seconds
SetOption32 | 1..100 | Set key hold time from 0.1 to 10 seconds
SetOption33 | | Show Sonoff Pow Max_Power_Retry value
SetOption33 | 1..250 | Set Sonoff Pow Max_Power_Retry from 1 to 250
```
### Logging
@ -430,6 +438,8 @@ PowerHigh | <watt> | Set power high threshold value
PowerLow | | Show current power low threshold value
PowerLow | 0 | off | (default) Disable power low threshold
PowerLow | <watt> | Set power low threshold value
SetOption33 | | Show Sonoff Pow Max_Power_Retry value
SetOption33 | 1..250 | Set Sonoff Pow Max_Power_Retry from 1 to 250
Status | 8 | Show Power usage
Status | 9 | Show Power thresholds
VoltageHigh | | Show current voltage high threshold value