# Kaifa MA105C Energy Meter
|
||||
In this example the Kaifa MA105C meter is used and might work with other meters too.
|
||||
In this example the Kaifa MA105C meter is used and might work with other meters as well.
|
||||
|
||||
## Schematics
|
||||
<img src="https://github.com/arendst/arendst.github.io/blob/master/media/wemos/wemos_kaifa_energy_meter_scematic.png" width="600">
|
||||
|
@ -13,15 +13,14 @@ In the Configuration -> Configure Module page, select the following:
|
|||
* Module Type : 18 Generic
|
||||
|
||||
## Tasmota Commands
|
||||
From the web console set the serial delimiter to 10 (newline). This makes tasmota publish each string of the telegram separately to mqtt.
|
||||
From the web console set the serial delimiter to 10 (newline). This makes tasmota publish each line of the telegram separately to mqtt.
|
||||
|
||||
```SerialDelimiter 10```
|
||||
|
||||
```SerialSend```
|
||||
|
||||
|
||||
## Example output
|
||||
Below an example of the telegram message published (per string) to mqtt. From here your HA system can process the data required for your needs.
|
||||
Below an example of the telegram message published (per line) to mqtt. From here your HA system can process the data required for your needs.
|
||||
|
||||
```
|
||||
16:59:39 MQT: tele/wemos-9/RESULT = {"SerialReceived":"/KFM5KAIFA-METER"}
|
||||
|
@ -52,6 +51,37 @@ Below an example of the telegram message published (per string) to mqtt. From he
|
|||
16:59:40 MQT: tele/wemos-9/RESULT = {"SerialReceived":"!EE58"}
|
||||
```
|
||||
|
||||
## Description of each line (see also [DSMR 5.0 - P1 Companion Standard](https://www.netbeheernederland.nl/_upload/Files/Slimme_meter_15_a727fce1f1.pdf))
|
||||
|
||||
```
|
||||
Header information - {"SerialReceived":"/KFM5KAIFA-METER"}
|
||||
Empty line - {"SerialReceived":""}
|
||||
Version information for P1 output - {"SerialReceived":"1-3:0.2.8(42)"}
|
||||
Date-time stamp of the P1 message - {"SerialReceived":"0-0:1.0.0(181227093413W)"}
|
||||
Equipment identifier - {"SerialReceived":"0-0:96.1.1(4530303235303030303639363432393136)"}
|
||||
electricityUsedTariff1 >> Meter Reading electricity delivered to client (Tariff 1) in 0,001 kWh - {"SerialReceived":"1-0:1.8.1(002293.192*kWh)"}
|
||||
electricityUsedTariff2 >> Meter Reading electricity delivered to client (Tariff 2) in 0,001 kWh - {"SerialReceived":"1-0:1.8.2(002523.640*kWh)"}
|
||||
Meter Reading electricity delivered by client (Tariff 1) in 0,001 kWh - {"SerialReceived":"1-0:2.8.1(000000.000*kWh)"}
|
||||
Meter Reading electricity delivered by client (Tariff 2) in 0,001 kWh - {"SerialReceived":"1-0:2.8.2(000000.000*kWh)"}
|
||||
electricityActiveTariff >> Tariff indicator electricity. The tariff indicator can also be used to switch tariff dependent loads e.g boilers. This is the responsibility of the P1 user - {"SerialReceived":"0-0:96.14.0(0002)"}
|
||||
Actual electricity power delivered (+P) in 1 Watt resolution - {"SerialReceived":"1-0:1.7.0(00.474*kW)"}
|
||||
Actual electricity power received (-P) in 1 Watt resolution - {"SerialReceived":"1-0:2.7.0(00.000*kW)"}
|
||||
Number of power failures in any phase - {"SerialReceived":"0-0:96.7.21(00000)"}
|
||||
Number of long power failures in any phase - {"SerialReceived":"0-0:96.7.9(00000)"}
|
||||
Power Failure Event Log (long power failures) - {"SerialReceived":"1-0:99.97.0(1)(0-0:96.7.19)(000101000001W)(2147483647*s)"}
|
||||
Number of voltage sags in phase L1 - {"SerialReceived":"1-0:32.32.0(00000)"}
|
||||
Number of voltage swells in phase L1 - {"SerialReceived":"1-0:32.36.0(00000)"}
|
||||
Text message max 1024 characters. - {"SerialReceived":"0-0:96.13.1()"}
|
||||
Text message max 1024 characters. - {"SerialReceived":"0-0:96.13.0()"}
|
||||
Instantaneous current L1 in A resolution - {"SerialReceived":"1-0:31.7.0(002*A)"}
|
||||
Instantaneous active power L1 (+P) in W resolution - {"SerialReceived":"1-0:21.7.0(00.474*kW)"}
|
||||
Instantaneous active power L1 (-P) in W resolution - {"SerialReceived":"1-0:22.7.0(00.000*kW)"}
|
||||
Device-Type - {"SerialReceived":"0-1:24.1.0(003)"}
|
||||
Equipment identifier (Gas) - {"SerialReceived":"0-1:96.1.0(4730303332353631323736373836373136)"}
|
||||
GasMeterReadingFiveMinutes >> Last 5-minute value (temperature converted), gas delivered to client in m3, including decimal values and capture time - {"SerialReceived":"0-1:24.2.1(181227090000W)(02910.491*m3)"}
|
||||
{"SerialReceived":"!5E3E"}
|
||||
```
|
||||
|
||||
Additional info
|
||||
* [Kaifa Meters (Dutch)](https://www.liander.nl/sites/default/files/Meters-Handleidingen-elektriciteit-Kaifa-uitgebreid.pdf)
|
||||
* [DSMR 5.0 - P1 Companion Standard](https://www.netbeheernederland.nl/_upload/Files/Slimme_meter_15_a727fce1f1.pdf)
|