The standard Sonoff device has a relay to turn on/off an external device and a button to toggle the state of the relay.
|
||||
|
||||
By default the confuguration for the button looks like this:
|
||||
By default the configuration for the button looks like this:
|
||||
|
||||
```
|
||||
SwitchMode=0 (Set switch mode to TOGGLE)
|
||||
|
@ -14,8 +14,8 @@ Instead the relay will be controlled directly. Once the relay changes its state
|
|||
e.g.: `stat/sonoff01/POWER ON`
|
||||
|
||||
**Important**:
|
||||
The Sonoff-Tasmota firmware does not publich the state of the switch in any way!
|
||||
It only send commands (directly to the corrosponding relay or via MQTT to a topic).
|
||||
The Sonoff-Tasmota firmware does not publish the state of the switch in any way!
|
||||
It only send commands (directly to the corresponding relay or via MQTT to a topic).
|
||||
|
||||
|
||||
# SwitchMode
|
||||
|
@ -28,14 +28,14 @@ You can change the mode for a switch by executing a [command](Commands) in the w
|
|||
|
||||
> Set switch mode to FOLLOW (0 = Off, 1 = On)
|
||||
|
||||
While pressing the button/switch (closeing the circuit) the button will send `ON` (directly or via MQTT depending on SwitchTopic) and `OFF` wehen released (open circuit).
|
||||
While pressing the button/switch (closing the circuit) the button will send `ON` (directly or via MQTT depending on SwitchTopic) and `OFF` when released (open circuit).
|
||||
|
||||
|
||||
**SwitchMode 2**
|
||||
|
||||
> Set switch mode to inverted FOLLOW (0 = On, 1 = Off)
|
||||
|
||||
The opposit of Mode 1.
|
||||
The opposite of Mode 1.
|
||||
|
||||
### Conclusion
|
||||
|
||||
|
@ -48,7 +48,7 @@ If the real switch is in the "on" position, the state of the software switch is
|
|||
|
||||
> Set switch mode to PUSHBUTTON (Normally 1, 0 = toggle)
|
||||
|
||||
The switch will send a command (directly or via MQTT) when the switch openes the circuit (`OFF`). When the closing the circuit (`ON`), nothing will happen.
|
||||
The switch will send a command (directly or via MQTT) when the switch opens the circuit (`OFF`). When closing the circuit (`ON`), nothing will happen.
|
||||
|
||||
**SwitchMode 4**
|
||||
|
||||
|
@ -60,7 +60,7 @@ The switch will send a command when changing to `ON`. Nothing happens when chang
|
|||
### Conclusion
|
||||
|
||||
When connecting a [momentary switch](https://en.wikipedia.org/wiki/Switch#Biased_switches) (a push button) you want to use `SwitchMode=3` or `4`.
|
||||
`SwitchMode=4` is the same as the default behaviour (`SwitchMode=0`) for Sonoff devices.
|
||||
`SwitchMode=4` is the same as the default behavior (`SwitchMode=0`) for Sonoff devices.
|
||||
|
||||