@ -7,11 +7,11 @@ The Shelly 1 is supported in Tasmota from version 6.2.1.7<br>
## ⚠Special Shelly Attention⚠ ## ⚠Special Shelly Attention⚠
**Do not connect AC power and the serial connection at the same time** **DO NOT CONNECT ANYTHING TO ANY GPIOs OF THESE DEVICES!!! (No sensors, no switches, nothing) <br>
The GND connection of the Shelly has a 50% chance of being connected to the live AC wire. Connecting serial with your PC will fry your PC. The GPIOs on the Shelly are connected to AC power!** Only use a SHelly as designed.
**Do not connect any additional sensors to serial pins.** **Do not connect AC power and the serial connection at the same time**
It can at least destroy your Shelly! The GND connection of the Shelly is connected to the live AC wire. Connecting serial with your PC will fry your PC.
**Check the correct jumper position before connecting AC power to Shelly 1.** **Check the correct jumper position before connecting AC power to Shelly 1.**
If the jumper is set to 12V you will destroy your Shelly! If the jumper is set to 12V you will destroy your Shelly!