Topic changed from ENERGY to SENSOR

RaymondMouthaan 2018-02-15 17:39:33 +01:00
parent efae55f8c1
commit a900f55618
1 changed files with 2 additions and 2 deletions

@ -46,7 +46,7 @@ The Sonoff Pow can provide Energy, Power, Voltage and Current information in dif
### Push result using Telemetry
The preffered way is using the periodic telemetry data. Setting ```teleperiod 300``` will send telemetry data every 5 minutes.
```
tele/pow1/ENERGY = {"Time":"2017-09-12T10:32:07", "Total":5.331, "Yesterday":0.152, "Today":0.067, "Period":0.5, "Power":6.1, "Factor":0.43, "Voltage":223.7, "Current":0.063}
tele/pow1/SENSOR = {"Time":"2018-02-15T17:37:10","ENERGY":{"Total":7.166,"Yesterday":0.376,"Today":0.113,"Period":1,"Power":38,"Factor":0.96,"Voltage":214,"Current":0.185}}
```
### Pull result using status message 8
@ -81,4 +81,4 @@ ITEAD published a recall notice for the Sonoff Pow on march 1st 2017. Some units
It is, in fact, possible to set a Maximum Power Threshold for the Sonoff Pow.
If the power measured by the device exceed the threshold set by the MQTT command MaxPower for a number of seconds set by the command MaxPowerHold the device will remain switched off for MaxPowerWindow seconds (to let it cool down, for example).
For all details see [Issue #218](https://github.com/arendst/Sonoff-Tasmota/issues/218)
For all details see [Issue #218](https://github.com/arendst/Sonoff-Tasmota/issues/218)