Updated Energy Saving (markdown)

Michael Ingraham 2019-03-03 08:12:57 -05:00
parent 8fe635f2f8
commit bbeebd8b85
1 changed files with 3 additions and 3 deletions

@ -41,9 +41,9 @@ All measurements were done with
- WiFi STA mode, enabled and connected (70%) - WiFi STA mode, enabled and connected (70%)
- MQTT enabled and connected - MQTT enabled and connected
- Syslog enabled and connected - Syslog enabled and connected
- `Teleperiod 60` for debugging - `TelePeriod 60` for debugging
- relays off - Relays off
- measure period of 24-56 h to reduce measuring fault - Measurement period of 24-56 hours to reduce measurement discrepancies
The first impression is that a higher sleep value reduce the consumption, but slightly. The second result is that using `Sleep <value>` (`value` &ne; 0, e. g. 1) is enough reducing the power consumption at minimum 1/3 up to 45 % (value=200). The first impression is that a higher sleep value reduce the consumption, but slightly. The second result is that using `Sleep <value>` (`value` &ne; 0, e. g. 1) is enough reducing the power consumption at minimum 1/3 up to 45 % (value=200).