@ -19,17 +19,15 @@ I used the following procedure to calibrate.
|
||||||
The Sonoff Pow can provide Energy, Power, Voltage and Current information in different ways.
|
The Sonoff Pow can provide Energy, Power, Voltage and Current information in different ways.
|
||||||
|
|
||||||
### Push result using Telemetry
|
### Push result using Telemetry
|
||||||
The preffered way is using the periodic telemetry data. Setting ```teleperiod 300``` will send telemetry data every 5 minutes. Depending on ```units``` the result would be:
|
The preffered way is using the periodic telemetry data. Setting ```teleperiod 300``` will send telemetry data every 5 minutes.
|
||||||
|
|
||||||
```
|
```
|
||||||
tele/pow1/TELEMETRY {"Time":"2017-01-01T13:50:17", "Energy":{"Yesterday":"0.234", "Today":"0.016", "Period":5, "Power":53, "Factor":"1.00", "Voltage":214, "Current":"0.247"}}
|
tele/pow1/ENERGY = {"Time":"2017-02-15T11:16:20", "Yesterday":0.012, "Today":0.000, "Period":0, "Power":4, "Factor":0.35, "Voltage":230, "Current":0.050}
|
||||||
```
|
```
|
||||||
|
|
||||||
### Pull result using status message 8
|
### Pull result using status message 8
|
||||||
To request information you can use command ```status 8``` which results in the following messages:
|
To request information you can use command ```status 8```.
|
||||||
|
|
||||||
```
|
```
|
||||||
stat/pow1/RESULT {"StatusPWR":{"Voltage":214, "Current":"0.247", "Power":53, "Today":"0.016", "Factor":"1.00"}}
|
stat/pow1/STATUS8 = {"StatusPWR":{"Yesterday":0.012, "Today":0.000, "Power":4, "Factor":0.36, "Voltage":228, "Current":0.054}}
|
||||||
```
|
```
|
||||||
|
|
||||||
### Meaning
|
### Meaning
|
||||||
|
@ -41,8 +39,8 @@ Yesterday | kWh | Total Energy usage between 00:00 and 24:00 yesterday
|
||||||
Today | kWh | Total Energy usage today from 00:00 until now
|
Today | kWh | Total Energy usage today from 00:00 until now
|
||||||
Period | Wh | Energy usage between previous message and now
|
Period | Wh | Energy usage between previous message and now
|
||||||
Power | W | Current power load
|
Power | W | Current power load
|
||||||
Voltage | V | Current line voltage
|
|
||||||
Current | A | Current line current
|
|
||||||
Factor | | The ratio of the real power flowing to the load to
|
Factor | | The ratio of the real power flowing to the load to
|
||||||
| | the apparent power in the circuit
|
| | the apparent power in the circuit
|
||||||
|
Voltage | V | Current line voltage
|
||||||
|