The Sonoff Pow can provide Energy, Power, Voltage and Current information in different ways.
### Push result using Telemetry
The preffered way is using the periodic telemetry data. Setting ```teleperiod 300``` will send telemetry data every 5 minutes. Depending on ```units``` the result would be:
The preffered way is using the periodic telemetry data. Setting ```teleperiod 300``` will send telemetry data every 5 minutes.
```
tele/pow1/TELEMETRY {"Time":"2017-01-01T13:50:17", "Energy":{"Yesterday":"0.234", "Today":"0.016", "Period":5, "Power":53, "Factor":"1.00", "Voltage":214, "Current":"0.247"}}
tele/pow1/ENERGY = {"Time":"2017-02-15T11:16:20", "Yesterday":0.012, "Today":0.000, "Period":0, "Power":4, "Factor":0.35, "Voltage":230, "Current":0.050}
```
### Pull result using status message 8
To request information you can use command ```status 8``` which results in the following messages:
To request information you can use command ```status 8```.
```
stat/pow1/RESULT {"StatusPWR":{"Voltage":214, "Current":"0.247", "Power":53, "Today":"0.016", "Factor":"1.00"}}
stat/pow1/STATUS8 = {"StatusPWR":{"Yesterday":0.012, "Today":0.000, "Power":4, "Factor":0.36, "Voltage":228, "Current":0.054}}
```
### Meaning
@ -41,8 +39,8 @@ Yesterday | kWh | Total Energy usage between 00:00 and 24:00 yesterday
Today | kWh | Total Energy usage today from 00:00 until now
Period | Wh | Energy usage between previous message and now
Power | W | Current power load
Voltage | V | Current line voltage
Current | A | Current line current
Factor | | The ratio of the real power flowing to the load to
| | the apparent power in the circuit
Voltage | V | Current line voltage
Current | A | Current line current
```