You might need to calibrate your power metering device as correct measurements are influenced by hardware and timing differences.
|
||||
|
||||
This is how to do it:
|
||||
|
||||
You will need a:
|
||||
- calibrated multimeter (AC capable)
|
||||
- incandescent light bulb (we use a 60W one in the example)
|
||||
- (optional) power meter (aka Kill A Watt)
|
||||
|
||||
1. Connect the light bulb to your device. (Optional: plug your device into the power meter)
|
||||
2. Open the Web UI for your device in one window and another window to that same devices Console
|
||||
3. Turn power on and wait a few seconds for the power metering to settle on a stable power reading
|
||||
4. Verify the **Power** reading in the web UI (optinal: and with the power meter) for the expected 60W and if needed change the power offset with command: <BR> `PowerSet 60.0`<BR> *(if you're using something with different power draw enter the appropriate number)*
|
||||
5. Verify the **Voltage** reading with the multimeter and if needed change the voltage offset in V with command: <BR> `VoltageSet 235.5`<BR> *(235.5 would be replaced with your measurement which varies depending on the electrical standards and your electrical grid)*
|
||||
6. Verify the **Current** reading by calculating current value (amperage) using formula **P<sub>(W)</sub>/I<sub>(V)</sub>=I<sub>(A)</sub>** and if needed change the current offset in *mA* (mA=A\*1000) with command:<BR> `CurrentSet 254.777`<BR> *(instead of 254.777 enter your calculation value of ***A multiplied by 1000***)*
|
||||
|
||||
Current calculation:
|
||||
```
|
||||
P/U=I
|
||||
W(atts)/(V)oltage=(A)mperes
|
||||
|
||||
watts/volts *1000=CurrentSet value
|
||||
(60.0/235.5)*1000=254.777
|
||||
```
|