Updated Smart Meter Interface Descriptors (markdown)

gemu 2019-09-03 19:33:46 +02:00
parent 2803b7af53
commit fecc1dc30a
1 changed files with 26 additions and 0 deletions

@ -3,6 +3,7 @@
- [Hager EHZ161 (OBIS)](#Hager-EHZ161-OBIS)
- [COMBO Meter (Water,Gas,SML)](#COMBO-Meter-WaterGasSML)
- [WOLF CSZ 11/300 Heater](#WOLF-CSZ-11300-Heater)
- [MODBUS Device](#MODBUS-Device)
------------------------------------------------------------------------------
#### Hager EHZ363 (SML)
@ -113,3 +114,28 @@
[Back To Top](#top)
------------------------------------------------------------------------------
#### MODBUS Device
>`>D`
>`>B`
=>sensor53 r
>`>M 1`
+1,3,m,0,9600,MODBUS,1,1,01040000,01040002,01040004,01040006,01040008,0104000a,0104000c,0104000e,01040010
>
>1,010404ffffffffxxxx@i0:1,Voltage P1,V,Voltage_P1,2
1,010404ffffffffxxxx@i1:1,Voltage P2,V,Voltage_P2,2
1,010404ffffffffxxxx@i2:1,Voltage P3,V,Voltage_P3,2
1,010404ffffffffxxxx@i3:1,Current P1,A,Current_P1,2
1,010404ffffffffxxxx@i4:1,Current P2,A,Current_P2,2
1,010404ffffffffxxxx@i5:1,Current P3,A,Current_P3,2
1,010404ffffffffxxxx@i6:1,active Power P1,W,Power_P1,2
1,010404ffffffffxxxx@i7:1,active Power P2,W,Power_P2,2
1,010404ffffffffxxxx@i8:1,actibe Power P3,W,Power_P3,2
\#
[Back To Top](#top)
------------------------------------------------------------------------------