#### 30. Simple solar heater control
|
||||
|
||||
In a swimming pool, a filter pump and a solar panel is installed. When the sun is shining, the pump should push water through the solar panel, to heat the pool. When it's night or cloudy, the pump should be off, to avoid cooling the pool water through the solar panel. The pump is controlled by a Sonoff TH10 with 2x DS18B20 sensors connected.
|
||||
|
||||
3 simple rules:
|
||||
|
||||
* Pump should start when solar panel is more than 2 deg warmer than the pool water
|
||||
* Pump should stop when solar panel is less than 1 deg varmer than the pool water
|
||||
* Pump should not start if the solar panel is below 25 deg celsius.
|
||||
|
||||
`t1`: pool temp
|
||||
|
||||
`t2`: panel temp
|
||||
|
||||
`var1`: in valid panel temp range?
|
||||
|
||||
`var2`: off threshold temp for panel
|
||||
|
||||
`var3`: on threshold temp for panel
|
||||
|
||||
`mem3`: lowest valid panel temp
|
||||
|
||||
```
|
||||
mem3 25
|
||||
rule1
|
||||
on DS18B20-1#temperature do
|
||||
event t1=%value%
|
||||
endon
|
||||
on DS18B20-2#temperature do
|
||||
event t2=%value%
|
||||
endon
|
||||
on event#t2>%mem3% do
|
||||
var1 1;
|
||||
endon
|
||||
on event#t2<=%mem3% do
|
||||
var1 0;
|
||||
endon
|
||||
on event#t1 do
|
||||
backlog
|
||||
var2 %value%;
|
||||
add2 1;
|
||||
endon
|
||||
on event#t1 do
|
||||
backlog
|
||||
var3 %value%;
|
||||
add3 2;
|
||||
endon
|
||||
on event#t2>%var3% do
|
||||
power1 %var1%;
|
||||
endon
|
||||
on event#t2<%var2% do
|
||||
power1 0;
|
||||
endon
|
||||
rule1 1
|
||||
```
|
||||
|
||||
To test the rule without having the sensors in place, simply enter the events for `t1` and `t2` in the console:
|
||||
|
||||
```
|
||||
event t1=21
|
||||
event t2=30
|
||||
```
|
||||
|
||||
And watch the relay turn on and off based on the values.
|
||||
|
||||
Please not that this example does not support manual override or handle missing sensor data. Take a look at [Simple Thermostat Example](#9-simple-thermostat-example) for examples.
|
||||
|
||||
|
||||