.. currentmodule:: machine
.. _machine.ADC:
class ADC -- analog to digital conversion
=========================================
The ADC class provides an interface to analog-to-digital converters, and
represents a single endpoint that can sample a continuous voltage and
convert it to a discretised value.
For extra control over ADC sampling see :ref:`machine.ADCBlock <machine.ADCBlock>`.
Example usage::
from machine import ADC
adc = ADC(pin) # create an ADC object acting on a pin
val = adc.read_u16() # read a raw analog value in the range 0-65535
val = adc.read_uv() # read an analog value in microvolts
Constructors
------------
.. class:: ADC(id, *, sample_ns, atten)
Access the ADC associated with a source identified by *id*. This
*id* may be an integer (usually specifying a channel number), a
:ref:`Pin <machine.Pin>` object, or other value supported by the
underlying machine.
If additional keyword-arguments are given then they will configure
various aspects of the ADC. If not given, these settings will take
previous or default values. The settings are:
- *sample_ns* is the sampling time in nanoseconds.
- *atten* specifies the input attenuation.
Methods
-------
.. method:: ADC.init(*, sample_ns, atten)
Apply the given settings to the ADC. Only those arguments that are
specified will be changed. See the ADC constructor above for what the
arguments are.
.. method:: ADC.block()
Return the :ref:`ADCBlock <machine.ADCBlock>` instance associated with
this ADC object.
This method only exists if the port supports the
:ref:`ADCBlock <machine.ADCBlock>` class.
.. method:: ADC.read_u16()
Take an analog reading and return an integer in the range 0-65535.
The return value represents the raw reading taken by the ADC, scaled
such that the minimum value is 0 and the maximum value is 65535.
.. method:: ADC.read_uv()
Take an analog reading and return an integer value with units of
microvolts. It is up to the particular port whether or not this value
is calibrated, and how calibration is done.