2019-11-13 06:33:14 +00:00
|
|
|
# This example finds and connects to a BLE temperature sensor (e.g. the one in ble_temperature.py).
|
|
|
|
|
|
|
|
import bluetooth
|
|
|
|
import random
|
|
|
|
import struct
|
|
|
|
import time
|
|
|
|
import micropython
|
|
|
|
|
|
|
|
from ble_advertising import decode_services, decode_name
|
|
|
|
|
|
|
|
from micropython import const
|
2020-02-27 04:36:53 +00:00
|
|
|
|
2020-05-11 12:20:07 +01:00
|
|
|
_IRQ_CENTRAL_CONNECT = const(1)
|
|
|
|
_IRQ_CENTRAL_DISCONNECT = const(2)
|
|
|
|
_IRQ_GATTS_WRITE = const(3)
|
|
|
|
_IRQ_GATTS_READ_REQUEST = const(4)
|
|
|
|
_IRQ_SCAN_RESULT = const(5)
|
|
|
|
_IRQ_SCAN_DONE = const(6)
|
|
|
|
_IRQ_PERIPHERAL_CONNECT = const(7)
|
|
|
|
_IRQ_PERIPHERAL_DISCONNECT = const(8)
|
|
|
|
_IRQ_GATTC_SERVICE_RESULT = const(9)
|
|
|
|
_IRQ_GATTC_SERVICE_DONE = const(10)
|
|
|
|
_IRQ_GATTC_CHARACTERISTIC_RESULT = const(11)
|
|
|
|
_IRQ_GATTC_CHARACTERISTIC_DONE = const(12)
|
|
|
|
_IRQ_GATTC_DESCRIPTOR_RESULT = const(13)
|
|
|
|
_IRQ_GATTC_DESCRIPTOR_DONE = const(14)
|
|
|
|
_IRQ_GATTC_READ_RESULT = const(15)
|
|
|
|
_IRQ_GATTC_READ_DONE = const(16)
|
|
|
|
_IRQ_GATTC_WRITE_DONE = const(17)
|
|
|
|
_IRQ_GATTC_NOTIFY = const(18)
|
|
|
|
_IRQ_GATTC_INDICATE = const(19)
|
2019-11-13 06:33:14 +00:00
|
|
|
|
2020-03-11 06:49:21 +00:00
|
|
|
_ADV_IND = const(0x00)
|
|
|
|
_ADV_DIRECT_IND = const(0x01)
|
|
|
|
_ADV_SCAN_IND = const(0x02)
|
|
|
|
_ADV_NONCONN_IND = const(0x03)
|
|
|
|
|
2019-11-13 06:33:14 +00:00
|
|
|
# org.bluetooth.service.environmental_sensing
|
|
|
|
_ENV_SENSE_UUID = bluetooth.UUID(0x181A)
|
|
|
|
# org.bluetooth.characteristic.temperature
|
|
|
|
_TEMP_UUID = bluetooth.UUID(0x2A6E)
|
2020-02-27 04:36:53 +00:00
|
|
|
_TEMP_CHAR = (
|
|
|
|
_TEMP_UUID,
|
|
|
|
bluetooth.FLAG_READ | bluetooth.FLAG_NOTIFY,
|
|
|
|
)
|
|
|
|
_ENV_SENSE_SERVICE = (
|
|
|
|
_ENV_SENSE_UUID,
|
|
|
|
(_TEMP_CHAR,),
|
|
|
|
)
|
2019-11-13 06:33:14 +00:00
|
|
|
|
|
|
|
# org.bluetooth.characteristic.gap.appearance.xml
|
|
|
|
_ADV_APPEARANCE_GENERIC_THERMOMETER = const(768)
|
|
|
|
|
2020-02-27 04:36:53 +00:00
|
|
|
|
2019-11-13 06:33:14 +00:00
|
|
|
class BLETemperatureCentral:
|
|
|
|
def __init__(self, ble):
|
|
|
|
self._ble = ble
|
|
|
|
self._ble.active(True)
|
|
|
|
self._ble.irq(handler=self._irq)
|
|
|
|
|
|
|
|
self._reset()
|
|
|
|
|
|
|
|
def _reset(self):
|
|
|
|
# Cached name and address from a successful scan.
|
|
|
|
self._name = None
|
|
|
|
self._addr_type = None
|
|
|
|
self._addr = None
|
|
|
|
|
|
|
|
# Cached value (if we have one)
|
|
|
|
self._value = None
|
|
|
|
|
|
|
|
# Callbacks for completion of various operations.
|
|
|
|
# These reset back to None after being invoked.
|
|
|
|
self._scan_callback = None
|
|
|
|
self._conn_callback = None
|
|
|
|
self._read_callback = None
|
|
|
|
|
|
|
|
# Persistent callback for when new data is notified from the device.
|
|
|
|
self._notify_callback = None
|
|
|
|
|
|
|
|
# Connected device.
|
|
|
|
self._conn_handle = None
|
|
|
|
self._value_handle = None
|
|
|
|
|
|
|
|
def _irq(self, event, data):
|
|
|
|
if event == _IRQ_SCAN_RESULT:
|
2020-03-11 06:49:21 +00:00
|
|
|
addr_type, addr, adv_type, rssi, adv_data = data
|
|
|
|
if adv_type in (_ADV_IND, _ADV_DIRECT_IND,) and _ENV_SENSE_UUID in decode_services(
|
|
|
|
adv_data
|
|
|
|
):
|
2019-11-13 06:33:14 +00:00
|
|
|
# Found a potential device, remember it and stop scanning.
|
|
|
|
self._addr_type = addr_type
|
2020-02-27 04:36:53 +00:00
|
|
|
self._addr = bytes(
|
|
|
|
addr
|
|
|
|
) # Note: addr buffer is owned by caller so need to copy it.
|
|
|
|
self._name = decode_name(adv_data) or "?"
|
2019-11-13 06:33:14 +00:00
|
|
|
self._ble.gap_scan(None)
|
|
|
|
|
2020-05-11 12:20:07 +01:00
|
|
|
elif event == _IRQ_SCAN_DONE:
|
2019-11-13 06:33:14 +00:00
|
|
|
if self._scan_callback:
|
|
|
|
if self._addr:
|
|
|
|
# Found a device during the scan (and the scan was explicitly stopped).
|
|
|
|
self._scan_callback(self._addr_type, self._addr, self._name)
|
|
|
|
self._scan_callback = None
|
|
|
|
else:
|
|
|
|
# Scan timed out.
|
|
|
|
self._scan_callback(None, None, None)
|
|
|
|
|
|
|
|
elif event == _IRQ_PERIPHERAL_CONNECT:
|
|
|
|
# Connect successful.
|
|
|
|
conn_handle, addr_type, addr, = data
|
|
|
|
if addr_type == self._addr_type and addr == self._addr:
|
|
|
|
self._conn_handle = conn_handle
|
|
|
|
self._ble.gattc_discover_services(self._conn_handle)
|
|
|
|
|
|
|
|
elif event == _IRQ_PERIPHERAL_DISCONNECT:
|
|
|
|
# Disconnect (either initiated by us or the remote end).
|
|
|
|
conn_handle, _, _, = data
|
|
|
|
if conn_handle == self._conn_handle:
|
|
|
|
# If it was initiated by us, it'll already be reset.
|
|
|
|
self._reset()
|
|
|
|
|
|
|
|
elif event == _IRQ_GATTC_SERVICE_RESULT:
|
|
|
|
# Connected device returned a service.
|
|
|
|
conn_handle, start_handle, end_handle, uuid = data
|
|
|
|
if conn_handle == self._conn_handle and uuid == _ENV_SENSE_UUID:
|
2020-02-27 04:36:53 +00:00
|
|
|
self._ble.gattc_discover_characteristics(
|
|
|
|
self._conn_handle, start_handle, end_handle
|
|
|
|
)
|
2019-11-13 06:33:14 +00:00
|
|
|
|
|
|
|
elif event == _IRQ_GATTC_CHARACTERISTIC_RESULT:
|
|
|
|
# Connected device returned a characteristic.
|
|
|
|
conn_handle, def_handle, value_handle, properties, uuid = data
|
|
|
|
if conn_handle == self._conn_handle and uuid == _TEMP_UUID:
|
|
|
|
self._value_handle = value_handle
|
|
|
|
# We've finished connecting and discovering device, fire the connect callback.
|
|
|
|
if self._conn_callback:
|
|
|
|
self._conn_callback()
|
|
|
|
|
|
|
|
elif event == _IRQ_GATTC_READ_RESULT:
|
|
|
|
# A read completed successfully.
|
|
|
|
conn_handle, value_handle, char_data = data
|
|
|
|
if conn_handle == self._conn_handle and value_handle == self._value_handle:
|
|
|
|
self._update_value(char_data)
|
|
|
|
if self._read_callback:
|
|
|
|
self._read_callback(self._value)
|
|
|
|
self._read_callback = None
|
|
|
|
|
|
|
|
elif event == _IRQ_GATTC_NOTIFY:
|
|
|
|
# The ble_temperature.py demo periodically notifies its value.
|
|
|
|
conn_handle, value_handle, notify_data = data
|
|
|
|
if conn_handle == self._conn_handle and value_handle == self._value_handle:
|
|
|
|
self._update_value(notify_data)
|
|
|
|
if self._notify_callback:
|
|
|
|
self._notify_callback(self._value)
|
|
|
|
|
|
|
|
# Returns true if we've successfully connected and discovered characteristics.
|
|
|
|
def is_connected(self):
|
|
|
|
return self._conn_handle is not None and self._value_handle is not None
|
|
|
|
|
|
|
|
# Find a device advertising the environmental sensor service.
|
|
|
|
def scan(self, callback=None):
|
|
|
|
self._addr_type = None
|
|
|
|
self._addr = None
|
|
|
|
self._scan_callback = callback
|
|
|
|
self._ble.gap_scan(2000, 30000, 30000)
|
|
|
|
|
|
|
|
# Connect to the specified device (otherwise use cached address from a scan).
|
|
|
|
def connect(self, addr_type=None, addr=None, callback=None):
|
|
|
|
self._addr_type = addr_type or self._addr_type
|
|
|
|
self._addr = addr or self._addr
|
|
|
|
self._conn_callback = callback
|
|
|
|
if self._addr_type is None or self._addr is None:
|
|
|
|
return False
|
|
|
|
self._ble.gap_connect(self._addr_type, self._addr)
|
|
|
|
return True
|
|
|
|
|
|
|
|
# Disconnect from current device.
|
|
|
|
def disconnect(self):
|
|
|
|
if not self._conn_handle:
|
|
|
|
return
|
|
|
|
self._ble.gap_disconnect(self._conn_handle)
|
|
|
|
self._reset()
|
|
|
|
|
|
|
|
# Issues an (asynchronous) read, will invoke callback with data.
|
|
|
|
def read(self, callback):
|
|
|
|
if not self.is_connected():
|
|
|
|
return
|
|
|
|
self._read_callback = callback
|
|
|
|
self._ble.gattc_read(self._conn_handle, self._value_handle)
|
|
|
|
|
|
|
|
# Sets a callback to be invoked when the device notifies us.
|
|
|
|
def on_notify(self, callback):
|
|
|
|
self._notify_callback = callback
|
|
|
|
|
|
|
|
def _update_value(self, data):
|
|
|
|
# Data is sint16 in degrees Celsius with a resolution of 0.01 degrees Celsius.
|
2020-02-27 04:36:53 +00:00
|
|
|
self._value = struct.unpack("<h", data)[0] / 100
|
2019-11-13 06:33:14 +00:00
|
|
|
return self._value
|
|
|
|
|
|
|
|
def value(self):
|
|
|
|
return self._value
|
|
|
|
|
|
|
|
|
|
|
|
def demo():
|
|
|
|
ble = bluetooth.BLE()
|
|
|
|
central = BLETemperatureCentral(ble)
|
|
|
|
|
|
|
|
not_found = False
|
|
|
|
|
|
|
|
def on_scan(addr_type, addr, name):
|
|
|
|
if addr_type is not None:
|
2020-02-27 04:36:53 +00:00
|
|
|
print("Found sensor:", addr_type, addr, name)
|
2019-11-13 06:33:14 +00:00
|
|
|
central.connect()
|
|
|
|
else:
|
|
|
|
nonlocal not_found
|
|
|
|
not_found = True
|
2020-02-27 04:36:53 +00:00
|
|
|
print("No sensor found.")
|
2019-11-13 06:33:14 +00:00
|
|
|
|
|
|
|
central.scan(callback=on_scan)
|
|
|
|
|
|
|
|
# Wait for connection...
|
|
|
|
while not central.is_connected():
|
|
|
|
time.sleep_ms(100)
|
|
|
|
if not_found:
|
|
|
|
return
|
|
|
|
|
2020-02-27 04:36:53 +00:00
|
|
|
print("Connected")
|
2019-11-13 06:33:14 +00:00
|
|
|
|
|
|
|
# Explicitly issue reads, using "print" as the callback.
|
|
|
|
while central.is_connected():
|
|
|
|
central.read(callback=print)
|
|
|
|
time.sleep_ms(2000)
|
|
|
|
|
|
|
|
# Alternative to the above, just show the most recently notified value.
|
|
|
|
# while central.is_connected():
|
|
|
|
# print(central.value())
|
|
|
|
# time.sleep_ms(2000)
|
|
|
|
|
2020-02-27 04:36:53 +00:00
|
|
|
print("Disconnected")
|
|
|
|
|
2019-11-13 06:33:14 +00:00
|
|
|
|
2020-02-27 04:36:53 +00:00
|
|
|
if __name__ == "__main__":
|
2019-11-13 06:33:14 +00:00
|
|
|
demo()
|