py/objgenerator: Fix unused variables when native gen extracts prelude.
Some compilers will warn about unused variables like scope_flags. So use MP_BC_PRELUDE_SIG_DECODE() which will silence these warnings. Signed-off-by: Damien George <damien@micropython.org>
This commit is contained in:
parent
768879f999
commit
9e3e67b1d8
|
@ -103,13 +103,10 @@ STATIC mp_obj_t native_gen_wrap_call(mp_obj_t self_in, size_t n_args, size_t n_k
|
|||
|
||||
// Extract n_state from the prelude.
|
||||
const uint8_t *ip = prelude_ptr;
|
||||
size_t n_state, n_exc_stack_unused, scope_flags, n_pos_args, n_kwonly_args, n_def_args;
|
||||
MP_BC_PRELUDE_SIG_DECODE_INTO(ip, n_state, n_exc_stack_unused, scope_flags, n_pos_args, n_kwonly_args, n_def_args);
|
||||
size_t n_exc_stack = 0;
|
||||
MP_BC_PRELUDE_SIG_DECODE(ip);
|
||||
|
||||
// Allocate the generator object, with room for local stack and exception stack
|
||||
mp_obj_gen_instance_t *o = m_new_obj_var(mp_obj_gen_instance_t, byte,
|
||||
n_state * sizeof(mp_obj_t) + n_exc_stack * sizeof(mp_exc_stack_t));
|
||||
// Allocate the generator object, with room for local stack (exception stack not needed).
|
||||
mp_obj_gen_instance_t *o = m_new_obj_var(mp_obj_gen_instance_t, byte, n_state * sizeof(mp_obj_t));
|
||||
o->base.type = &mp_type_gen_instance;
|
||||
|
||||