mirror of https://github.com/arendst/Tasmota.git
Improvements to remote temp, auto clear time for MiElHVAC (#22379)
* Add prohibit function for MiElHVAC
Add Prohibit functions:
* Power
* Temperature
* Mode
and all combinations of this functions
Updated VaneV names for better identify
* Fixed Compressor and Operation for MiElHVAC
Changed Widevane position name from ISEE to AUTO sam as in MELCLoud
* Revert "Fixed Compressor and Operation for MiElHVAC"
This reverts commit f0973c84d4
.
* New feature for MiElHVAC
* Added Compressor map
* Added Operation Power in Watts
* Added Operation Energy in kWh
* Changed Widevane position name from ISEE to AUTO, displays sam as in
* Changed all map value to lover case MELCloud
* New feature for MiElHVAC
* Add device operation time in minutes
* New feature Outdoor Temperature for MiElHVAC
* Add Outdoor Temperature
* New feature Compressor Frequency for MiElHVAC
* Added Outdoor Temperature
* Renamed internal properties due typo operating and oprating to operation
* New feature Auto Clear Remote Temp for MiElHVAC
* This PR add auto clear remote temperature function
* This funcion is call on first run and after 10 sec the remote temperature stop refresh its value
* Send manually Clear command is also available
* change function name, small corrections
* added auto clear time configurable using cmnd
* Improvements to remote temp, auto clear time for MiElHVAC
* Added min = 1000ms and max 600000ms limit to remotetemp auto clear time function
* Changed function name to use sam format as other
* Added RemoteTemperatureSensor to the sensor
* more improvements to auto clear time
* Changed RemoteTemperatureSensor to RemoteTemperatureSensorState
* Added RemoteTemperatureSensorAutoClearTime to the sensor output
This commit is contained in:
parent
fc0dc5dfec
commit
18bfda50ab
|
@ -949,7 +949,7 @@ miel_hvac_remotetemp_degc2old(long degc)
|
||||||
}
|
}
|
||||||
|
|
||||||
static void
|
static void
|
||||||
miel_hvac_auto_clear_remotetemp(void)
|
miel_hvac_remotetemp_auto_clear(void)
|
||||||
{
|
{
|
||||||
struct miel_hvac_softc *sc = miel_hvac_sc;
|
struct miel_hvac_softc *sc = miel_hvac_sc;
|
||||||
struct miel_hvac_msg_remotetemp *rt = &sc->sc_remotetemp;
|
struct miel_hvac_msg_remotetemp *rt = &sc->sc_remotetemp;
|
||||||
|
@ -972,7 +972,7 @@ miel_hvac_cmnd_remotetemp_auto_clear_time(void)
|
||||||
return;
|
return;
|
||||||
|
|
||||||
unsigned long clear_time = strtoul(XdrvMailbox.data, nullptr, 10);
|
unsigned long clear_time = strtoul(XdrvMailbox.data, nullptr, 10);
|
||||||
if (clear_time == 0) {
|
if (clear_time < 1000 || clear_time > 600000) {
|
||||||
miel_hvac_respond_unsupported();
|
miel_hvac_respond_unsupported();
|
||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
@ -997,7 +997,6 @@ miel_hvac_cmnd_remotetemp(void)
|
||||||
degc = 0;
|
degc = 0;
|
||||||
|
|
||||||
ResponseCmndChar_P("clear");
|
ResponseCmndChar_P("clear");
|
||||||
remotetemp_clear = false;
|
|
||||||
remotetemp_last_call_time = 0;
|
remotetemp_last_call_time = 0;
|
||||||
} else {
|
} else {
|
||||||
degc = strtol(XdrvMailbox.data, nullptr, 0);
|
degc = strtol(XdrvMailbox.data, nullptr, 0);
|
||||||
|
@ -1009,7 +1008,6 @@ miel_hvac_cmnd_remotetemp(void)
|
||||||
degc = MIEL_HVAC_REMOTETEMP_MAX;
|
degc = MIEL_HVAC_REMOTETEMP_MAX;
|
||||||
|
|
||||||
ResponseCmndNumber(degc);
|
ResponseCmndNumber(degc);
|
||||||
remotetemp_clear = true;
|
|
||||||
remotetemp_last_call_time = millis();
|
remotetemp_last_call_time = millis();
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@ -1027,6 +1025,8 @@ miel_hvac_cmnd_remotetemp(void)
|
||||||
rt->temp_old = miel_hvac_remotetemp_degc2old(degc);
|
rt->temp_old = miel_hvac_remotetemp_degc2old(degc);
|
||||||
rt->temp = (degc + MIEL_HVAC_REMOTETEMP_OFFSET) *
|
rt->temp = (degc + MIEL_HVAC_REMOTETEMP_OFFSET) *
|
||||||
MIEL_HVAC_REMOTETEMP_OLD_FACTOR;
|
MIEL_HVAC_REMOTETEMP_OLD_FACTOR;
|
||||||
|
|
||||||
|
remotetemp_clear = control == MIEL_HVAC_REMOTETEMP_SET ? true : false;
|
||||||
}
|
}
|
||||||
|
|
||||||
#ifdef MIEL_HVAC_DEBUG
|
#ifdef MIEL_HVAC_DEBUG
|
||||||
|
@ -1406,6 +1406,14 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
|
||||||
ResponseAppend_P(PSTR(",\"Temperature\":\"%s\""),
|
ResponseAppend_P(PSTR(",\"Temperature\":\"%s\""),
|
||||||
room_temp);
|
room_temp);
|
||||||
|
|
||||||
|
ResponseAppend_P(PSTR(",\"RemoteTemperatureSensorState\":\"%s\""),
|
||||||
|
remotetemp_clear ? "ON" : "OFF");
|
||||||
|
|
||||||
|
char remotetempautocleartime[33];
|
||||||
|
ultoa(remotetemp_auto_clear_time, remotetempautocleartime, 10);
|
||||||
|
ResponseAppend_P(PSTR(",\"RemoteTemperatureSensorAutoClearTime\":\"%s\""),
|
||||||
|
remotetempautocleartime);
|
||||||
|
|
||||||
if(rt->outdoortemp > 1) {
|
if(rt->outdoortemp > 1) {
|
||||||
char outdoor_temp[33];
|
char outdoor_temp[33];
|
||||||
float temp = miel_hvac_outdoortemp2deg(rt->outdoortemp);
|
float temp = miel_hvac_outdoortemp2deg(rt->outdoortemp);
|
||||||
|
@ -1636,7 +1644,7 @@ bool Xdrv44(uint32_t function) {
|
||||||
case FUNC_EVERY_200_MSECOND:
|
case FUNC_EVERY_200_MSECOND:
|
||||||
case FUNC_EVERY_SECOND:
|
case FUNC_EVERY_SECOND:
|
||||||
if (remotetemp_clear && ((millis() - remotetemp_last_call_time) > remotetemp_auto_clear_time || remotetemp_last_call_time == 0)) {
|
if (remotetemp_clear && ((millis() - remotetemp_last_call_time) > remotetemp_auto_clear_time || remotetemp_last_call_time == 0)) {
|
||||||
miel_hvac_auto_clear_remotetemp();
|
miel_hvac_remotetemp_auto_clear();
|
||||||
}
|
}
|
||||||
break;
|
break;
|
||||||
|
|
||||||
|
|
Loading…
Reference in New Issue