New features for MiElHVAC (#22423)

* Add prohibit function for MiElHVAC

Add Prohibit functions:
* Power
* Temperature
* Mode
 and all combinations of this functions
Updated VaneV names for better identify

* Fixed Compressor and Operation for MiElHVAC

Changed Widevane position name from ISEE to AUTO sam as in MELCLoud

* Revert "Fixed Compressor and Operation for MiElHVAC"

This reverts commit f0973c84d4.

* New feature for MiElHVAC

* Added Compressor map
* Added Operation Power in Watts
* Added Operation Energy in kWh
* Changed Widevane position name from ISEE to AUTO, displays sam as in
* Changed all map value to lover case MELCloud

* New feature for MiElHVAC

* Add device operation time in minutes

* New feature Outdoor Temperature for MiElHVAC

* Add Outdoor Temperature

* New feature Compressor Frequency for MiElHVAC

* Added Outdoor Temperature
* Renamed internal properties due typo operating and oprating to operation

* New feature Auto Clear Remote Temp for MiElHVAC

* This PR add auto clear remote temperature function
* This funcion is call on first run and after 10 sec the remote temperature stop refresh its value
* Send manually Clear command is also available

* change function name, small corrections

* added auto clear time configurable using cmnd

* Improvements to remote temp, auto clear time for MiElHVAC

* Added min = 1000ms and max 600000ms limit to remotetemp auto clear time function
* Changed function name to use sam format as other
* Added RemoteTemperatureSensor to the sensor

* more improvements to auto clear time

* Changed RemoteTemperatureSensor to RemoteTemperatureSensorState
* Added RemoteTemperatureSensorAutoClearTime to the sensor output

* New feature Timers for MiElHVAC

* Added Timers to the sensor output:
  * TimerMode - none, on, off, on_and_off
  * TimerOn - display time to ON
  * TimerOnRemaining - display remaining time to ON
  * TimerOff - display time to OFF
    * TimerOffRemaining - display remaining time to OFF

* New feature for Stage and more for MiElHVAC

* Added to sensor output:
  * Added PrerunStage - on/off, report compressor prepare stage before start working
  * FanStage - off, quiet, 1, 2, 3 ,4 ,5, report current fan stage
  * ModeStage - manual(heat, dry, cool, fan_only, heat_isee, dry_isee, cool_isee), auto_fan, auto_heat, auto_cool, report current mode
  * Renamed Bytes to Settings for raw data

* Renamed const UPDATE to SETTINGS
* Moved SETTINGS const from miel_hvac_msg_settings to miel_hvac_data_settings
* Renamed some functions name to get better code readable

* Removed some empty lines
* Refactor some structure of code to make more clean and better readable

* remove duplicate settings request

* New features for MiElHVAC

* Changed PrerunStage to OperationStage
* Updated map for OperationStage
* Updated map for ModeStage
* Changed map fan_only to fan
* Cleanup
This commit is contained in:
Grzegorz 2024-11-03 21:31:35 +01:00 committed by GitHub
parent 133cca3fd5
commit 56243ef720
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194
1 changed files with 21 additions and 14 deletions

View File

@ -180,9 +180,12 @@ struct miel_hvac_data_status
struct miel_hvac_data_stage
{
uint8_t _pad1[2];
uint8_t prerun;
#define MIEL_HVAC_STAGE_PRERUN_OFF 0x00
#define MIEL_HVAC_STAGE_PRERUN_ON 0x04
uint8_t operation;
#define MIEL_HVAC_STAGE_OPERATION_NORMAL 0x00
#define MIEL_HVAC_STAGE_OPERATION_UNKNOWN 0x01
#define MIEL_HVAC_STAGE_OPERATION_DEFROST 0x02
#define MIEL_HVAC_STAGE_OPERATION_STANDBY 0x03
#define MIEL_HVAC_STAGE_OPERATION_PREHEAT 0x04
uint8_t fan;
#define MIEL_HVAC_STAGE_FAN_OFF 0x00
#define MIEL_HVAC_STAGE_FAN_1 0x01
@ -196,6 +199,7 @@ struct miel_hvac_data_stage
#define MIEL_HVAC_STAGE_MODE_AUTO_FAN 0x01
#define MIEL_HVAC_STAGE_MODE_AUTO_HEAT 0x02
#define MIEL_HVAC_STAGE_MODE_AUTO_COOL 0x03
#define MIEL_HVAC_STAGE_MODE_AUTO_LEADER 0x04
};
struct miel_hvac_data
@ -210,7 +214,7 @@ struct miel_hvac_data
union
{
struct miel_hvac_data_settings settings;
struct miel_hvac_data_roomtemp roomtemp;;
struct miel_hvac_data_roomtemp roomtemp;
struct miel_hvac_data_timers timers;
struct miel_hvac_data_status status;
struct miel_hvac_data_stage stage;
@ -243,7 +247,7 @@ CTASSERT(offsetof(struct miel_hvac_data, data.timers.offminutes) == 5);
CTASSERT(offsetof(struct miel_hvac_data, data.timers.onminutesremaining) == 6);
CTASSERT(offsetof(struct miel_hvac_data, data.timers.offminutesremaining) == 7);
CTASSERT(offsetof(struct miel_hvac_data, data.stage.prerun) == 3);
CTASSERT(offsetof(struct miel_hvac_data, data.stage.operation) == 3);
CTASSERT(offsetof(struct miel_hvac_data, data.stage.fan) == 4);
CTASSERT(offsetof(struct miel_hvac_data, data.stage.mode) == 5);
@ -403,7 +407,7 @@ static const struct miel_hvac_map miel_hvac_mode_map[] = {
{MIEL_HVAC_SETTINGS_MODE_HEAT, "heat"},
{MIEL_HVAC_SETTINGS_MODE_DRY, "dry"},
{MIEL_HVAC_SETTINGS_MODE_COOL, "cool"},
{MIEL_HVAC_SETTINGS_MODE_FAN, "fan_only"},
{MIEL_HVAC_SETTINGS_MODE_FAN, "fan"},
{MIEL_HVAC_SETTINGS_MODE_AUTO, "auto"},
{MIEL_HVAC_SETTINGS_MODE_HEAT_ISEE, "heat_isee"},
{MIEL_HVAC_SETTINGS_MODE_DRY_ISEE, "dry_isee"},
@ -469,9 +473,12 @@ static const struct miel_hvac_map miel_hvac_timer_mode_map[] = {
{MIEL_HVAC_TIMER_MODE_BOTH, "on_and_off"},
};
static const struct miel_hvac_map miel_hvac_stage_prerun_map[] = {
{MIEL_HVAC_STAGE_PRERUN_OFF, "off"},
{MIEL_HVAC_STAGE_PRERUN_ON, "on"},
static const struct miel_hvac_map miel_hvac_stage_operation_map[] = {
{MIEL_HVAC_STAGE_OPERATION_NORMAL, "normal"},
{MIEL_HVAC_STAGE_OPERATION_UNKNOWN, "unknown"},
{MIEL_HVAC_STAGE_OPERATION_DEFROST, "defrost"},
{MIEL_HVAC_STAGE_OPERATION_STANDBY, "standby"},
{MIEL_HVAC_STAGE_OPERATION_PREHEAT, "preheat"},
};
static const struct miel_hvac_map miel_hvac_stage_fan_map[] = {
@ -489,6 +496,7 @@ static const struct miel_hvac_map miel_hvac_stage_mode_map[] = {
{MIEL_HVAC_STAGE_MODE_AUTO_FAN, "auto_fan"},
{MIEL_HVAC_STAGE_MODE_AUTO_HEAT, "auto_heat"},
{MIEL_HVAC_STAGE_MODE_AUTO_COOL, "auto_cool"},
{MIEL_HVAC_STAGE_MODE_AUTO_LEADER, "auto_leader"},
};
enum miel_hvac_parser_state
@ -545,7 +553,6 @@ miel_hvac_update_settings_pending(struct miel_hvac_softc *sc)
}
static struct miel_hvac_softc *miel_hvac_sc = nullptr;
static void miel_hvac_input_connected(struct miel_hvac_softc *, const void *, size_t);
static void miel_hvac_input_data(struct miel_hvac_softc *, const void *, size_t);
static void miel_hvac_input_updated(struct miel_hvac_softc *, const void *, size_t);
@ -1078,7 +1085,7 @@ miel_hvac_cmnd_remotetemp(void)
update->temp_old = miel_hvac_remotetemp_degc2old(degc);
update->temp = (degc + MIEL_HVAC_REMOTETEMP_OFFSET) * MIEL_HVAC_REMOTETEMP_OLD_FACTOR;
remotetemp_last_call_time = control == MIEL_HVAC_REMOTETEMP_SET ? millis() : 0;
remotetemp_last_call_time = control == MIEL_HVAC_REMOTETEMP_SET ? millis() : 0;
remotetemp_clear = control == MIEL_HVAC_REMOTETEMP_SET ? true : false;
}
@ -1516,10 +1523,10 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
const struct miel_hvac_data_stage *stage = &sc->sc_stage.data.stage;
char hex[(sizeof(sc->sc_stage) + 1) * 2];
name = miel_hvac_map_byval(stage->prerun, miel_hvac_stage_prerun_map, nitems(miel_hvac_stage_prerun_map));
name = miel_hvac_map_byval(stage->operation, miel_hvac_stage_operation_map, nitems(miel_hvac_stage_operation_map));
if (name != NULL)
{
ResponseAppend_P(PSTR(",\"PrerunStage\":\"%s\""), name);
ResponseAppend_P(PSTR(",\"OperationStage\":\"%s\""), name);
}
name = miel_hvac_map_byval(stage->fan, miel_hvac_stage_fan_map, nitems(miel_hvac_stage_fan_map));