* Add prohibit function for MiElHVAC
Add Prohibit functions:
* Power
* Temperature
* Mode
and all combinations of this functions
Updated VaneV names for better identify
* Fixed Compressor and Operation for MiElHVAC
Changed Widevane position name from ISEE to AUTO sam as in MELCLoud
* Revert "Fixed Compressor and Operation for MiElHVAC"
This reverts commit f0973c84d4.
* New feature for MiElHVAC
* Added Compressor map
* Added Operation Power in Watts
* Added Operation Energy in kWh
* Changed Widevane position name from ISEE to AUTO, displays sam as in
* Changed all map value to lover case MELCloud
- Add command ``DaliSend <address>|<address+256>,<command>`` to send command (address+256 is repeat) on DALI bus
- Add command ``DaliQuery <address>|<address+256>,<command>`` to send command (address+256 is repeat) on DALI bus and wait up to DALI_TIMEOUT ms for response
On ESP32, with `#define JPEG_PICTS` without the scripter, build fails due to the function `Draw_jpeg` being defined after use. Order swapped to satisfy the compiler.
Change tested to compile without errors, but not being 100% sure of when/how it is supposed to work, no verification of this.
Prevent from sending more then one Modbus TCP response
for a single request.
This might happen in the following scenario where,
shortly after the first response has been sent (4),
the second one will be send (8) (note the same
'TransactionId') triggered by the response to the
'ModbusSend' request issued by Berry (5).
The log excerpt from such a situation:
(1) 21:13:20.510 MBS: MBRTCP to Modbus TransactionId:520, deviceAddress:4, functionCode:3, startAddress:8193, count:1, recvCount:1, recvBytes:2
(2) 21:13:20.523 MBS: Serial Send: 04 03 20 01 00 01 DE 5F
(3) 21:13:20.647 MBS: Serial Received: 04 03 02 0A 28 72 FA
(4) 21:13:20.652 MBS: MBRTCP from Modbus TransactionId:520, deviceAddress:4, writing:11 bytes to client (error:0)
(5) 21:13:20.724 CMD: Grp 0, Cmd 'MODBUSSEND', Idx 1, Len 89, Pld -99, Data '{"deviceAddress":4, "functionCode":6, "startAddress":8192, "type":"uint16", "Values":[6]}'
(6) 21:13:20.743 MBS: Serial Send: 04 06 20 00 00 06 02 5D
(7) 21:13:21.009 MBS: Serial Received: 04 06 20 00 00 06 02 5D
(8) 21:13:21.014 MBS: MBRTCP from Modbus TransactionId:520, deviceAddress:4, writing:12 bytes to client (error:0)
Use 'tcp_transaction_id' field to denote that we already
sent a response.
Signed-off-by: Damian Wrobel <dwrobel@ertelnet.rybnik.pl>
* Add heat/dry/cool isee operation mode to xdrv_44_miel_hvac.ino
This add heat, dry, and cool isle operation mode to support new AC devices. Closes also #10937
* remove duplicated wide vane mode