5.8.0m
* Rewrite code (partly) using Google C++ Style Guide
(https://google.github.io/styleguide/cppguide.html)
* Allow empty
MqttHost name by using option 0
* Allow Mqtt server mDNS lookup only
when MqttHost name is empty (#1026)
* Change Ws2812 clock with more
flexible version (#1019)
* Add German language file (#1022)
* Support
connecting to MQTT brokers without userid and/or password (#1023)
* Add
commands PwmRange 1,255..1023 and PwmFrequency 1,100..4000 (#1025)
5.8.0j
* Set default altitude to 0 to be used with pressure sensors
*
Document flash settings area for future use
* Prepare for 32-bit power
control (#995)
* Introduce sonoff.h master header
* Fix TLS MQTT SSL
fingerprint test (#808, #970)
* Fix pressure calculation for some BMP
versions regression introduced with version 5.8.0i (#974)
* Fix
Domoticz Dimmer set to same level not powering on (#945)
5.8.0i
* Add Domoticz counter sensor to IrReceive representing Received
IR Protocol and Data
* Fix Southern Hemisphere TIME_STD/TIME_DST
(#968)
* Add Sea level pressure calculation (#974)
* Fix virtual relay
status message used with Color/Dimmer control (#989)
* Fix command
IRSend and IRHvac case sensitive parameter regression introduced with
version 5.8.0 (#993)
5.8.0f
* Set all saved power settings to Off when SetOption0
(SaveState) = 0 (#955)
* Allow PWM initialization after restart (#955)
* Add support for inverted PWM (#960)
5.8.0d
* Remove previous GPIO configuration when another module is
selected
* Fix inverted relay power on state (#909)
* Change default
PWM assignments for H801 RGB(CW) led controller to support optional
Color/Dimmer control
* GPIO04 (W2) from GPIO_PWM2 to GPIO_USER to
be user configurable for GPIO_PWM5 (second White - Warm if W1 is Cold)
* GPIO12 (Blue) GPIO_PWM3 no change
* GPIO13 (Green) from
GPIO_PWM4 to GPIO_PWM2
* GPIO14 (W1) from GPIO_PWM1 to GPIO_USER
to be user configurable for GPIO_PWM4 (first White - Cold or Warm)
*
GPIO15 (Red) from GPIO_PWM5 to GPIO_PWM1
* Change default PWM
assignments for MagicHome RGB(W) led controller to support optional
Color/Dimmer control
* GPIO05 (Green) from GPIO_PWM4 to GPIO_PWM2
*
GPIO12 (Blue) from GPIO_PWM5 to GPIO_PWM3
* GPIO13 (White) GPIO_USER
to be user configurable for GPIO_PWM4 (White - Cold or Warm)
* GPIO14
(Red) from GPIO_PWM3 to GPIO_PWM1
* Add command SetOption15 0
(default) for command PWM control or SetOption15 1 for commands
Color/Dimmer control to PWM RGB(CW) leds (#941)
5.6.1 20170818
* Change module list order in webpage
* Fix Sonoff T1 1CH and 2CH configuration (#751)
*
* 5.6.0 20170818
* Fix Sonoff Pow intermittent exception 0
* Change Sonoff Pow sending Domoticz telemetry data only
* Add Ai-Thinker RGBW led (AiLight) (experimental)
* Add NeoPixelBus library to Sonoff Led for Hue support
* Add user configurable GPIO4 and GPIO5 to module Sonoff Bridge
* Add Sonoff B1 RGBCW led support with command Color RRGGBBCCWW (#676)
* Add command CT 152..500 to Sonoff Led and Sonoff B1 to control Color
Temperature
* Add Cold-Warm slider to web page for Sonoff Led and Sonoff B1
* Add CT parameter to Hue
* Add Sonoff T1 support (#582)
* Add AnalogInput0 if configured as Analog Input to webpage (#697, #746)
* Add command SetOption14 0|1 to enable interlock mode (#719, #721)
* Fix Mitsubishi HVAC IR power controll (#740)
5.5.1 20170805
* Fix Sonoff Rf Bridge issues
* Add Sonoff RF Bridge MQTT messages on received and learned RF signal
* Add command VoltRes 0|1 to select voltage resolution to 0.1 V (#654)
* Add averaging to Analog input (#686)
* Add Energy tele data on Sonoff Pow Threshold change (#688)
* Fix inconsistent property names in Messages (#690)
5.5.0 20170730
* Reduce code space by removing the following commands as they are
replaced by SetOption alternatives:
* SaveState = SetOption0
* ButtonRestrict = SetOption1
* Units = SetOption2
* MQTT = SetOption3
* MQTTResponse = SetOption4
* TempUnit = SetOption8
* Smoothing WS2812 animation poll, invert fade speed and max allowed
wakeup time down to 3000 seconds
* Fix initial button press detection
* Add support for Sonoff RF Bridge 433 using command RfKey
* Fix regression from 5.0.7 by increasing message buffer size from 360
to 368 to accomodate 4 x DS18x20 sensors (#637)
* Add GroupTopic to Topic test when using ButtonTopic/SwitchTopic to
send either ON/OFF or TOGGLE (#642)
* Adjust HLW calibration limits to accomodate HuaFan device and add
commands HlwPSet, HlwUSet and HlwISet (#654)
5.4.0 20170725
* Fix command reset regression introduced in 5.2.0
* Increase polling from 0.1 second to 0.05 second
* Add multipress to all buttons
* Fix button 1 double press behaviour on multi relay devices
* Add support for Hua Fan Smart Socket (#479)
* Add support for Sonoff 4ch Pro (#565)
* Add command SetOption13 1 to allow immediate action on single button
press
* (disables multipress, hold and unrestricted commands) (#587)
5.2.0 20170619
* Add command SetOption12 1 to disable newly released configuration
flash rotate to reduce flash wear
* Fix command CounterDebounce by removing test for active GPIO (#524)
* Add command SetOption33 1..250 to allow user configure POW
Max_Power_Retry count (#525)
5.1.7 20170616
* Prep removal of SetOptions alternatives
* Restore webpage upgrade error messages removed in 5.1.5
* Add hold button functionality to buttons 2 to 4
* Add command SetOption32 1..100 to set Key Hold Time from 0.1 seconds
to 10 seconds (#200)
* Allow slashes in Topic, GroupTopic, ButtonTopic and SwitchTopic (#507)
* Changed webpage form actions from post to get and use relative path
url (#434, #522)
5.1.6 20170606
* Shrink code
* Removed online configuration of Domoticz In and Domoticz Out MQTT
strings
* Removed commands DomoticzInTopic and DomoticzOutTopic
* Add define KEY_HOLD_TIME to configure button hold threshold before
sending MQTT Hold message
* Add command StateText4 to configure button MQTT Hold text (=
MQTT_CMND_HOLD)
* Add command SetOption11 0|1 to swap pushbutton single and double press
functionality (#200)
* Add command SwitchMode<x> 5 (PUSHBUTTONHOLD) and 6
(PUSHBUTTONHOLD_INV) (#489)
5.1.1 20170517
* Allow command FullTopic in group mode
* Prepare for more use of RTC memory
* Add independant WS2812 led string power control (#386, #390)
* Add command Counter<x> to control up to four GPIO falling edge
interrupt counters or timers (#459)
* Add command CounterType<x> to select between pulse counting or pulse
timing
* Add command CounterDebounce to select global counter debounce time in
mSec
5.1.0 20170513
* Fix Offline/Removal of retained topic when FullTopic is changed
* Add FullTopic to MQTT Configuration and Information web page
* Adde license model GPLv3 (#188)
5.0.7 20170511
* Fix possible exception 28 on empty command
* Add command SetOption0 as replacement for SaveState
* Add command SetOption1 as replacement for ButtonRestrict
* Add command SetOption2 as replacement for Units
* Add command SetOption4 as replacement for MqttResponse
* Add command SetOption8 as replacement for TempUnit
* Add command SetOption10 On|Off to select between Offline or Removing
previous retained topic (#417, #436)
5.0.6 20170510
* Remove hyphen in case of a single DHT sensor connecetd (#427)
* Add command MqttRetry <seconds> to change default MQTT reconnect retry
timer from minimal 10 seconds (#429)
5.0.5 20170508
* Add command FullTopic with tokens %topic% (replaced by command Topic
value) and
* %prefix% (replaced by command Prefix<x> values) for more flexible
topic definitions (#244)
* See wiki > MQTT Features
https://github.com/arendst/Sonoff-Tasmota/wiki/MQTT-Features for more
information
5.0.4 20170505
* Add Sonoff Pow Energy Total up to 40 MWh
* Add command EnergyReset 1|2|3 to reset Energy counters (#406)
* Fix Domoticz Energy logging (#411)
* Add command PowerOnState 4 to keep relay always on and disabling all
power control (#418)
5.0.3 20170504
* Add command SensorRetain on|off to enable retaining of mqtt message
tele/sonoff/SENSOR (#74)
* Change WifiConfig timeout from 60 seconds to 180 seconds (#212)
* Change Sonoff Touch command Ledstate functionality by turning led on
if power is off (#214)
* Add 4 seconds delay after power on before enabling button to
workaround Wemos D1 mini RTS circuit (#380)
5.0.2 20170503
* Reset SaveData, SaveState and MqttResponse to default values due to
rearranging settings
* Moved some settings flag area
* Add command TempUnit Celsius|Fahrenheit for selecting Celsius or
Fahrenheit (#347)
* Add command TempRes 0..3 for selecting Temperature Resolution (#347)
* Add command HumRes 0..3 for selecting Humidity Resolution (#347)
* Add command PressRes 0..3 for selecting Pressure Resolution (#347)
* Add command EnergyRes 0..5 for selecting Energy Resolution (#347)
* Add "TemperatureUnit":"C|F" to sensor JSON output (#347)
* Add support for up to three DHT type sensors each using a different
GPIO (#339, #404)
4.1.1 20170329
* Fix default Telemetry for command Prefix3
* Fix webserver Module parameters for disabled select
* Fix sensor status for enabled switches
* Remove Light as alternative for Power (save code space)
* Remove migration option from pre V3 (code cleanup)
* Remove unofficial SPIFFS support (code cleanup)
* Remove command list when unknown command is entered (save code space)
* Rename Status11 json from StatusPWR to unique StatusSTS
* Rename command Gateway to IPAddres2, Subnetmask to IPAddress3 and
DnsServer to IPAddress4 (save code space)
* Add Command MqttResponse to select either command or RESULT topic as
response (#258)
* Add command StateText1 to StateText3 to assign MQTT_STATUS_OFF,
MQTT_STATUS_ON and MQTT_CMND_TOGGLE respectively (#286)
* Remove restart after IPAddress changes (#292)
* Add support for MAX31850 in xsns_ds18x20.ino (#295)
* Fix possible uptime update misses (#302)
4.1.0 20170325
* Change static IP addresses in user_config.h from list (using commas)
to string (using dots)
* Unify display result of commands Modules, Module and Gpios
* Rewrite Module selection web page to bring size down from 18651 to
4319 bytes (!) (#234, #240)
* Add basic support for (Lixada) H801 RGBWW controller (#252)
* Add command Prefix1 to Prefix3 to assign SUB_PREFIX, PUB_PREFIX and
PUB_PREFIX2 respectively (#255)
* Add static ip addresses to flash (#262)
* Add commands IpAddress, Gateway, Subnetmask and DnsServer to select
static ip addresses (#273)
4.0.8 20170321
* Fix entering non-numeric webpassword
* Force selection between TLS or Webserver due to memory restraint
(#240)
* Allow entering empty string using "0" for selected commands (#242)
* Fix exception when posting commands to web console containing % (#250)
4.0.7 20170319
* Increased Sonoff Led PWM frequency from 432 to 1000
* Fix possible watch dog reboot after changing module type on web page
* Fix reporting of GPIO usage from web page
* Fix Sonoff Led blank during firmware upgrade
* Fix Sonoff Led flicker and possible flash corruption by using latest
Arduino-esp8266 versions
* of pwm core files included in sonoff library (#211)
* Add PWM output control with commands PWM1 to PWM5 using user
selectable GPIOs (#211)
* Fix exceptions due to low values of commands HlwPCal (10000), HlwUCal
(1000) and HlwICal (2500) (#223)
* Add Switch state to sensor status (#227, #233)
* Add user configuarble GPIO to module Sonoff Touch (#228)
* Add define WEB_PORT to user_config.h to change default web server port
from 80 (#232)
* Fix failed Ota Firmware upgrade started from Web page (#235)
4.0.5 20170314
* Add command Status 11 to show power status with Vcc if define
USE_ADC_VCC is enabled (default)
* Add ADC input to Sonoff SV and Wemos D1 mini - Needs recompile with
define USE_ADC_VCC disabled (#137)
* Add MQTT host:port to timeout message (#199)
4.0.5 20170314
* Add command Status 11 to show power status with Vcc if define
USE_ADC_VCC is enabled (default)
* Add ADC input to Sonoff SV and Wemos D1 mini - Needs recompile with
define USE_ADC_VCC disabled (#137)
* Add MQTT host:port to timeout message (#199)
4.0.4 20170312
* Add pulse timers for up to 4 relays (#106)
* Fix Sonoff Led power state when dimmer or color is 0 (#176)
* Add command NtpServer<x> to configure up to three NTP servers (#177)
* Delete module User Test as module Wemos D1 mini has same/more user
configurable GPIO (#178)
* Add more user configurable GPIO to module ElectroDragon (#183)
4.0.2 20170308
* Restore correct seriallog level after Serial logging was disabled
* Add simple dimmer slider to Sonoff Led web page
* Reduced root webpage size by 31%
* Expand Status 2 with Build date/time and core version
* Fix webserver redirection when not in WifiManager mode (#156)
* Add command ButtonRestrict On/Off to restrict access to button hold
and button multi press options above 2 (#161)
* Fix DS18S20 negative temperature readings (#165)
* Fix crlf compilation error due to bad syntax (#144, #167)
4.0.0 20170303
* Add define to remove config migration code for versions below 3.0 (See
Wiki-Upgrade-Migration path)
* Free memory by switching from String to char[]
* Raised Sonoff Led PWM frequency from 200Hz to 432Hz in search of
stability (hardware watchdog timeouts) (#122)
* Increase message size and suggested minimum MQTT_MAX_PACKET_SIZE to
512 (#114, #124)
* Remove runtime warning message regarding MQTT_MAX_PACKET_SIZE too
small as it is now moved to compile time (#124)
* Fix possible panics with web console and http commands while UDP
syslog is active (#127)
* Add optional static IP address (#129)
* Add define ENERGY_RESOLUTION in user_config.h to allow user control
over precision (#136)
3.9.22 20170228
* Update web console
* Fix Status 4 JSON message
* Add Exception info during restart if available
* Add osWatch service to detect loop hangs that might happen during
(OTA) upgrades
* Add WiOn support for relay and switch only (#82, #102)
* Allow for user specified relay count up to four in sonoff_template.h
(#109)
* Add support for HTU21 compatible I2C sensors SI7013, SI7020 and SI7021
(#118)
* Add NodeMCU or Wemos configuration option (#119)
3.9.21 20170224
* Add ajax to web root page and web console (#79)
* Add commands SwitchMode1..4 and enable user switches 2, 3 and 4 (#84,
#88)
* Fix MQTT upgrade when webserver is active