5.8.0b
* Fix command FullTopic entry when using serial or console
interface
* Fix possible UDP syslog blocking
* Add debug information
to MQTT subscribe
* Add Domoticz sensors for Voltage and Current (#903)
5.7.1d
* Fix watchdog timeout caused by lack of stack space by now
using global buffers (#853)
* Removed webserver syslog disable as now
no longer needed
* Increased default MQTT message size from 368 to 405
bytes while keeping DMQTT_MAX_PACKET_SIZE = 512 (because we can)
* Fix
MQTT Offline or Remove MQTT retained topic code
* Allow command
SwitchTopic in group mode (#861)
* Allow command SwitchMode if no
switches are defined (#861)
5.5.1 20170805
* Fix Sonoff Rf Bridge issues
* Add Sonoff RF Bridge MQTT messages on received and learned RF signal
* Add command VoltRes 0|1 to select voltage resolution to 0.1 V (#654)
* Add averaging to Analog input (#686)
* Add Energy tele data on Sonoff Pow Threshold change (#688)
* Fix inconsistent property names in Messages (#690)
5.5.0 20170730
* Reduce code space by removing the following commands as they are
replaced by SetOption alternatives:
* SaveState = SetOption0
* ButtonRestrict = SetOption1
* Units = SetOption2
* MQTT = SetOption3
* MQTTResponse = SetOption4
* TempUnit = SetOption8
* Smoothing WS2812 animation poll, invert fade speed and max allowed
wakeup time down to 3000 seconds
* Fix initial button press detection
* Add support for Sonoff RF Bridge 433 using command RfKey
* Fix regression from 5.0.7 by increasing message buffer size from 360
to 368 to accomodate 4 x DS18x20 sensors (#637)
* Add GroupTopic to Topic test when using ButtonTopic/SwitchTopic to
send either ON/OFF or TOGGLE (#642)
* Adjust HLW calibration limits to accomodate HuaFan device and add
commands HlwPSet, HlwUSet and HlwISet (#654)
5.2.0 20170619
* Add command SetOption12 1 to disable newly released configuration
flash rotate to reduce flash wear
* Fix command CounterDebounce by removing test for active GPIO (#524)
* Add command SetOption33 1..250 to allow user configure POW
Max_Power_Retry count (#525)
5.1.6 20170606
* Shrink code
* Removed online configuration of Domoticz In and Domoticz Out MQTT
strings
* Removed commands DomoticzInTopic and DomoticzOutTopic
* Add define KEY_HOLD_TIME to configure button hold threshold before
sending MQTT Hold message
* Add command StateText4 to configure button MQTT Hold text (=
MQTT_CMND_HOLD)
* Add command SetOption11 0|1 to swap pushbutton single and double press
functionality (#200)
* Add command SwitchMode<x> 5 (PUSHBUTTONHOLD) and 6
(PUSHBUTTONHOLD_INV) (#489)
5.1.1 20170517
* Allow command FullTopic in group mode
* Prepare for more use of RTC memory
* Add independant WS2812 led string power control (#386, #390)
* Add command Counter<x> to control up to four GPIO falling edge
interrupt counters or timers (#459)
* Add command CounterType<x> to select between pulse counting or pulse
timing
* Add command CounterDebounce to select global counter debounce time in
mSec
5.1.0 20170513
* Fix Offline/Removal of retained topic when FullTopic is changed
* Add FullTopic to MQTT Configuration and Information web page
* Adde license model GPLv3 (#188)
5.0.6 20170510
* Remove hyphen in case of a single DHT sensor connecetd (#427)
* Add command MqttRetry <seconds> to change default MQTT reconnect retry
timer from minimal 10 seconds (#429)
5.0.4 20170505
* Add Sonoff Pow Energy Total up to 40 MWh
* Add command EnergyReset 1|2|3 to reset Energy counters (#406)
* Fix Domoticz Energy logging (#411)
* Add command PowerOnState 4 to keep relay always on and disabling all
power control (#418)
5.0.2 20170503
* Reset SaveData, SaveState and MqttResponse to default values due to
rearranging settings
* Moved some settings flag area
* Add command TempUnit Celsius|Fahrenheit for selecting Celsius or
Fahrenheit (#347)
* Add command TempRes 0..3 for selecting Temperature Resolution (#347)
* Add command HumRes 0..3 for selecting Humidity Resolution (#347)
* Add command PressRes 0..3 for selecting Pressure Resolution (#347)
* Add command EnergyRes 0..5 for selecting Energy Resolution (#347)
* Add "TemperatureUnit":"C|F" to sensor JSON output (#347)
* Add support for up to three DHT type sensors each using a different
GPIO (#339, #404)
5.0.1 20170429
* Adjust Sonoff SC messages to prepare for display feature
* Move static data from RAM to Flash
* Fix PowerOnState for some devices not reporting "Power on" state
(#284, #380, #383)
5.0.0 20170425
* Memory status message update
* Fix setting migration to better preserve settings during move (#382)
* Best practice is first doing a Backup Configuration before installing
version 5.0.0
* Reset save count after setting move
* Start using new linker script without SPIFFS
4.1.2 20170403
* Rename Unrecognised command to Unknown command
* Remove all command lists
* Remove command SmartConfig (superseded by WifiConfig)
* Fix boot loop when selecting module Sonoff 4CH or Sonoff Touch on non
ESP8285 hardware
* Add optional support for Toshiba and Mitsubishi HVAC IR control (needs
updated IRanother (#257)
* Add all configured switches to Domoticz Configuration web page (#305)
* Fix compile error when selecting WS2812 DMA (#313)
4.1.1 20170329
* Fix default Telemetry for command Prefix3
* Fix webserver Module parameters for disabled select
* Fix sensor status for enabled switches
* Remove Light as alternative for Power (save code space)
* Remove migration option from pre V3 (code cleanup)
* Remove unofficial SPIFFS support (code cleanup)
* Remove command list when unknown command is entered (save code space)
* Rename Status11 json from StatusPWR to unique StatusSTS
* Rename command Gateway to IPAddres2, Subnetmask to IPAddress3 and
DnsServer to IPAddress4 (save code space)
* Add Command MqttResponse to select either command or RESULT topic as
response (#258)
* Add command StateText1 to StateText3 to assign MQTT_STATUS_OFF,
MQTT_STATUS_ON and MQTT_CMND_TOGGLE respectively (#286)
* Remove restart after IPAddress changes (#292)
* Add support for MAX31850 in xsns_ds18x20.ino (#295)
* Fix possible uptime update misses (#302)
4.1.0 20170325
* Change static IP addresses in user_config.h from list (using commas)
to string (using dots)
* Unify display result of commands Modules, Module and Gpios
* Rewrite Module selection web page to bring size down from 18651 to
4319 bytes (!) (#234, #240)
* Add basic support for (Lixada) H801 RGBWW controller (#252)
* Add command Prefix1 to Prefix3 to assign SUB_PREFIX, PUB_PREFIX and
PUB_PREFIX2 respectively (#255)
* Add static ip addresses to flash (#262)
* Add commands IpAddress, Gateway, Subnetmask and DnsServer to select
static ip addresses (#273)
4.0.7 20170319
* Increased Sonoff Led PWM frequency from 432 to 1000
* Fix possible watch dog reboot after changing module type on web page
* Fix reporting of GPIO usage from web page
* Fix Sonoff Led blank during firmware upgrade
* Fix Sonoff Led flicker and possible flash corruption by using latest
Arduino-esp8266 versions
* of pwm core files included in sonoff library (#211)
* Add PWM output control with commands PWM1 to PWM5 using user
selectable GPIOs (#211)
* Fix exceptions due to low values of commands HlwPCal (10000), HlwUCal
(1000) and HlwICal (2500) (#223)
* Add Switch state to sensor status (#227, #233)
* Add user configuarble GPIO to module Sonoff Touch (#228)
* Add define WEB_PORT to user_config.h to change default web server port
from 80 (#232)
* Fix failed Ota Firmware upgrade started from Web page (#235)
4.0.2 20170308
* Restore correct seriallog level after Serial logging was disabled
* Add simple dimmer slider to Sonoff Led web page
* Reduced root webpage size by 31%
* Expand Status 2 with Build date/time and core version
* Fix webserver redirection when not in WifiManager mode (#156)
* Add command ButtonRestrict On/Off to restrict access to button hold
and button multi press options above 2 (#161)
* Fix DS18S20 negative temperature readings (#165)
* Fix crlf compilation error due to bad syntax (#144, #167)
4.0.1 20170305
* Fix char default sizes and set MESSZ to 360 (#143)
* Fix SerialLog setting status
* Disable syslog when emulation is active
* Add DS18B20 web page display refresh
4.0.0 20170303
* Add define to remove config migration code for versions below 3.0 (See
Wiki-Upgrade-Migration path)
* Free memory by switching from String to char[]
* Raised Sonoff Led PWM frequency from 200Hz to 432Hz in search of
stability (hardware watchdog timeouts) (#122)
* Increase message size and suggested minimum MQTT_MAX_PACKET_SIZE to
512 (#114, #124)
* Remove runtime warning message regarding MQTT_MAX_PACKET_SIZE too
small as it is now moved to compile time (#124)
* Fix possible panics with web console and http commands while UDP
syslog is active (#127)
* Add optional static IP address (#129)
* Add define ENERGY_RESOLUTION in user_config.h to allow user control
over precision (#136)
3.9.22 20170228
* Update web console
* Fix Status 4 JSON message
* Add Exception info during restart if available
* Add osWatch service to detect loop hangs that might happen during
(OTA) upgrades
* Add WiOn support for relay and switch only (#82, #102)
* Allow for user specified relay count up to four in sonoff_template.h
(#109)
* Add support for HTU21 compatible I2C sensors SI7013, SI7020 and SI7021
(#118)
* Add NodeMCU or Wemos configuration option (#119)
3.9.15 20170213
* Change JSON float values from string to number according to
http://json.org (#56)
* Add support for exs latched relay module
https://ex-store.de/ESP8266-WiFi-Relay-V31 (#58)
* Add support for inverted relays
* Changed MAX_LOG_LINES from 70 to 60 to preserve memory
3.9.11 20170204
* Fix command I2Cscan
* Fix not allowed spaces in Topic, ButtonTopic and SwitchTopic
* Make all TELEMETRY, STATUS and COMMAND message topics unique (#4)
* Advertise command topic to be used by iobroker (#299)
* Fix butten (non)detection if no GPIO_KEY1 is defined (#13)
* Change WeMo serialnumber from 7 decimal chars to 8 hexadecimal chars
(#18)
* Update web page with Build Date/Time, Emulation and mDNS Discovery and
Advertise information (#21)
3.9.11 20170204
* Fix command I2Cscan
* Fix not allowed spaces in Topic, ButtonTopic and SwitchTopic
* Make all TELEMETRY, STATUS and COMMAND message topics unique (#4)
* Advertise command topic to be used by iobroker (#299)
* Fix butten (non)detection if no GPIO_KEY1 is defined (#13)
* Change WeMo serialnumber from 7 decimal chars to 8 hexadecimal chars
(#18)
* Update web page with Build Date/Time, Emulation and mDNS Discovery and
Advertise information (#21)
3.9.9 20170130
* Add command status 10 showing sensor data
* Fix hlw status messages if hlw is disabled
* Remove GPIO07 and GPIO08 from user selectable (#5)