authentik/website/docs/security/CVE-2023-26481.md

1.3 KiB

CVE-2023-26481

Reported by @fuomag9

Insufficient user check in FlowTokens by Email stage

Summary

Due to an insufficient access check, a recovery flow link that is created by an admin (or sent via email by an admin) can be used to set the password for any arbitrary user.

Patches

authentik 2022.12.3, 2023.1.3, 2023.2.3 fix this issue.

Impact

This attack is only possible if a recovery flow exists, which has both an Identification and an Email stage bound to it. If the flow has policies on the identification stage to skip it when the flow is restored (by checking request.context['is_restored']), the flow is not affected by this. With this flow in place, an administrator must create a recovery Link or send a recovery URL to the attacker, who can, due to the improper validation of the token create, set the password for any account.

Workaround

It is recommended to upgrade to the patched version of authentik. Regardless, for custom recovery flows it is recommended to add a policy that checks if the flow is restored, and skips the identification stage.

For more information

If you have any questions or comments about this advisory: