Commit Graph

22 Commits

Author SHA1 Message Date
arendst 3890170ea4 Add BME680 support 2017-12-06 17:16:16 +01:00
arendst 6331ee7c8f Add experimental MH-Z19(B) support
Add (experimental) support for sensor MH-Z19(B) to be enabled with
define USE_MHZ19 in user_config.h (#561, #1248)
2017-12-04 17:25:06 +01:00
arendst 253d60fd2b Add experimental SI7021 support
* Add (experimental) support for iTead SI7021 temperature and humidity
sensor (#735)
 * Change ADS1115 default voltage range from +/-2V to
+/-6V (#1289)
2017-12-03 14:06:15 +01:00
arendst 7117179c1d v5.10.0a Add sensor SHT3X
5.10.0a
 * Add (experimental) support for sensor SHT3x
2017-12-01 15:59:53 +01:00
arendst 0f531e24e5 v5.9.1j - Add Dual R2, Rewrite DS18x20 and fixes
5.9.1j
 * Revert changes to xsns_05_ds18x20.ino and rename to
xsns_05_ds18x20_legacy.ino still needing library OneWire and providing
legacy JSON message:
 *
"DS18x20":{"DS1":{"Type":"DS18B20","Address":"284CC48E04000079","Temperature":19.5},"DS2":{"Type":"DS18B20","Address":"283AC28304000052","Temperature":19.6}}

* Add new xdrv_05_ds18x20.ino free from library OneWire and add the
following features:
 *  Add support for DS1822
 *  Add forced setting of
12-bit resolution for selected device types (#1222)
 *  Add read
temperature retry counter (#1215)
 *  Fix lost sensors by performing
sensor probe at restart only thereby removing dynamic sensor probe
(#1215)
 *  Fix sensor address sorting using ascending sort on sensor
type followed by sensor address
 *  Rewrite JSON resulting in shorter
message allowing more sensors in default firmware image:
 *
"DS18B20-1":{"Id":"00000483C23A","Temperature":19.5},"DS18B20-2":{"Id":"0000048EC44C","Temperature":19.6}

* Add additional define in user_config.h to select either single sensor
(defines disabled), new multi sensor (USE_DS18X20) or legacy multi
sensor (USE_DS18X20_LEGACY)
 * Add support for Sonoff Dual R2 (#1249)
 *
Fix ADS1115 detection (#1258)
2017-11-27 17:46:51 +01:00
arendst 512566c727 v5.9.1i - Rewrite DS18x20 sensor code
5.9.1i
 * Fix Arilux LC11 restart exception 0 after OTA upgrade
 *
Disabled CRC lookup-table in OneWire.h (#define ONEWIRE_CRC8_TABLE 0) to
save some code space
 * Rewrite xsns_05_ds18x20.ino adding support for
DS1822, correct address calculation and force setting 12-bit resolution
(#1222)
 * DS18x20 sensor reconfiguration now only probed at restart
removing dynamic connection and intermittent sensor loss (#1215)
2017-11-24 17:26:20 +01:00
arendst 9c74a4a041 v5.9.1e - Fixes and Additions
5.9.1e
 * Add + (plus) and - (minus) to command color to select 1 out of
12 preset colors
 * Add + (plus) and - (minus) to command ct to control
ColdWarm led ColorTemperature (+34/-34)
 * Tune Arilux RF code
 * Fix
possible iram1_0_seg compile error by shrinking ICACHE_RAM_ATTR code
 *
Update core_esp8266_wiring_digital.c to latest (staged) level
 *
Workaround Sonoff Bridge Learn Mode hang caused by unrecognised RF code
(#1181)
 * Fix blank console log window by using XML character encoding
(#1187)
2017-11-17 17:52:31 +01:00
arendst db4a3a4a1e v5.9.1d - Add Arilux LC11 support
5.9.1d
 * Add support for Arilux LC11 (CLearing RF home code when
selecting no Arilux module)
 * Add fixed color options 1..12 to command
Color
 * Add + (plus) and - (minus) to commands Dimmer (+10/-10), Speed
and Scheme
2017-11-15 23:07:45 +01:00
arendst 83a9c0693a v5.9.1b - Add INA219 support
5.9.1b
 * Remove spaces in JSON messages
 * Add support for INA219
Voltage and Current sensor to be enabled in user_config.h
2017-11-11 12:33:30 +01:00
arendst 19533cc995 v5.9.0b - Fixes and add ADS1115 A/D converter
5.9.0b
 * Add support for ADS1115 to be enabled in user_config.h and
needs libraries i2cdevlib-Core and i2cdevlib-ADS1115 (#338, #660)
 * Fix
Exception 26 and empty console screen after usage of command
WakeupDuration (#1133)
 * Fix some changed iTead web links in README.md
(#1137)
2017-11-07 15:57:24 +01:00
arendst d5cf0fc57f Expand bridge functionality 2017-10-30 11:42:34 +01:00
arendst ebe642c995 v5.8.0q Fixes and Shrinking code
5.8.0q
 * Shrink code by 4k using command lookup tables
 * Add retry
counter to DHT11/21/22 sensors (#1082)
 * Add commands RfSync, RfLow,
RfHigh, RfHost and RfCode to allow sending custom RF codes (#1001)
2017-10-29 18:18:46 +01:00
arendst cf350dc584 v5.8.0o - Add VEML6070 and more light schemes
5.8.0o
 * Remove max string length of 14 for Domoticz sensor
descriptions
 * Add light scheme options (Color cycle Up, Down, Random)
and moving WS2812 schemes up by 3
 * Add support for VEML6070 I2C Ultra
Violet level sensor (#1053)
2017-10-25 14:27:30 +02:00
arendst fc89330056 v5.8.0m - Rewrite and Additions
5.8.0m
 * Rewrite code (partly) using Google C++ Style Guide
(https://google.github.io/styleguide/cppguide.html)
 * Allow empty
MqttHost name by using option 0
 * Allow Mqtt server mDNS lookup only
when MqttHost name is empty (#1026)
 * Change Ws2812 clock with more
flexible version (#1019)
 * Add German language file (#1022)
 * Support
connecting to MQTT brokers without userid and/or password (#1023)
 * Add
commands PwmRange 1,255..1023 and PwmFrequency 1,100..4000 (#1025)
2017-10-18 18:22:34 +02:00
arendst ff52288efe v5.8.0i - Some fixes and Add Sealevel Pressure
5.8.0i
 * Add Domoticz counter sensor to IrReceive representing Received
IR Protocol and Data
 * Fix Southern Hemisphere TIME_STD/TIME_DST
(#968)
 * Add Sea level pressure calculation (#974)
 * Fix virtual relay
status message used with Color/Dimmer control (#989)
 * Fix command
IRSend and IRHvac case sensitive parameter regression introduced with
version 5.8.0 (#993)
2017-10-08 16:51:05 +02:00
arendst 3bc7dd4e83 v5.8.0h - Add IR Receive
5.8.0h
 * Rename command IRRemote to IRSend (#956)
 * Add IR Receiver
support. Disable in user_config.h (#956)
 * Change default PWM
assignment for Witty Cloud to support optional Color/Dimmer control
(#976)
 *   GPIO12 (Green) from GPIO_PWM4 to GPIO_PWM2
 *   GPIO13
(Blue)  from GPIO_PWM5 to GPIO_PWM3
 *   GPIO15 (Red)   from GPIO_PWM3
to GPIO_PWM1
2017-10-06 17:28:00 +02:00
arendst 107b746083 v5.8.0c
5.8.0c
 * Add warning to webpage when USE_MINIMAL is selected (#929)
 *
Fix compile error when DOMOTICZ_UPDATE_TIMER is not defined (#930)
 *
Fix alignment of web page items in some browsers (#935)
 * Add smoother
movement of hour hand in WS2812 led clock (#936)
 * Add support for
Magic Home RGBW Led controller (#940)
2017-09-30 13:32:53 +02:00
arendst e974dcb7b7 v5.8.0b - Add Domoticz Voltage and Current
5.8.0b
 * Fix command FullTopic entry when using serial or console
interface
 * Fix possible UDP syslog blocking
 * Add debug information
to MQTT subscribe
 * Add Domoticz sensors for Voltage and Current (#903)
2017-09-26 15:10:58 +02:00
Theo Arends 33e116ccb9 v5.8.0a - Fix GPIOx JSON response
5.8.0a
 * Add translations to I2Cscan
 * Add translation to BH1750 unit
lx
 * Set default WS2812 pixel count to WS2812_LEDS
 * Fix command GPIOx
JSON response (#897)
2017-09-23 11:12:16 +02:00
arendst e015b574e6 v5.7.1g - Add wificonfig option 5 (WIFI_WAIT)
5.7.1g
 * Add option WIFI_WAIT (5) to command WifiConfig to allow
connection retry to same AP without restart or update flash (#772, #869)
2017-09-16 14:19:47 +02:00
arendst 2d5fc29976 v5.7.1e - Add Sonoff SC debugging
5.7.1e
 * Add Sonoff SC debug information
 * Change syslog service
2017-09-14 14:20:27 +02:00
arendst 0fbbc23b2c Add I18n and fix invalid JSON
5.6.1i
* Add basic internationalization and localization (#763)
* Fix invalid JSON (#822)
2017-09-02 14:37:02 +02:00